Accuracy enhancement of magnetic field distribution measurements within a large cell spin-exchange relaxation-free magnetometer

被引:7
|
作者
Gusarov, Alexander [1 ,2 ]
Baranga, Andrei Ben-Amar [2 ]
Levron, David [2 ]
Shuker, Reuben [2 ]
机构
[1] Tamar Reg Council, Dead Sea & Arava Sci Ctr, IL-86910 Tamar, Israel
[2] Ben Gurion Univ Negev, Dept Phys, IL-84105 Beer Sheva, Israel
关键词
atomic magnetometer; SERF; 3D measurements; multifactorial design;
D O I
10.1088/1361-6501/aaa702
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The factorial design technique is implemented to achieve greater accuracy in the determination of magnetic field distribution within a single cell of spin-exchange relaxation-free atomic magnetometer. Three-dimensional magnetic field distribution within a single vapor cell can be found by consecutively pumping, layer by layer, all the cell volumes perpendicular to the probe laser beam, detected by a photodiode array. Thus each element of the array collects information about the magnetic field in the small volume (voxel) which forms when the corresponding part of the probe beam and optically pumped layer cross. One of the most effective ways to enhance measurement accuracy is repeated pumping of the layers and averaging the measured results. However, the measurement time is multiplied several times due to the repeated scanning of the cell volume. The suggested technique enables increased measurement accuracy of each voxel while preserving the number of measurements. Magnetic field distribution is determined by the illumination of the cell layers one by one or simultaneously, according to a special algorithm, with subsequent multifactorial analysis of the obtained results.
引用
收藏
页数:7
相关论文
共 33 条
  • [1] Measurement of Relaxation Mechanism for the Spin-Exchange Relaxation-Free Magnetometer
    Peng, Jin
    Xu, An-Ning
    Yin, Yiran
    Liu, Bei
    IEEE SENSORS JOURNAL, 2024, 24 (02) : 1333 - 1339
  • [2] Femtotesla Spin-Exchange Relaxation-Free Atomic Magnetometer With a Multipass Cell
    Qi, Yibo
    Li, Bo
    Wang, Shuying
    Xu, Nuozhou
    Qian, Yujie
    Lu, Jixi
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73
  • [3] In-situ measurement of magnetic field gradient in a magnetic shield by a spin-exchange relaxation-free magnetometer
    房建成
    王涛
    张红
    李阳
    蔡洪炜
    Chinese Physics B, 2015, 24 (06) : 257 - 262
  • [4] In-situ measurement of magnetic field gradient in a magnetic shield by a spin-exchange relaxation-free magnetometer
    Fang Jian-Cheng
    Wang Tao
    Zhang Hong
    Li Yang
    Cai Hong-Wei
    CHINESE PHYSICS B, 2015, 24 (06)
  • [5] A miniaturized spin-exchange relaxation-free atomic magnetometer based on uniform light field
    Li, Jiajie
    Fang, Xiujie
    Li, Renjie
    Chen, Baodong
    Zhai, Yueyang
    Liu, Ying
    CHINESE PHYSICS B, 2023, 32 (05)
  • [6] Analysis on the Magnetic Field Response for Nuclear Spin Co-Magnetometer Operated in Spin-Exchange Relaxation-Free Regime
    Fan, Wenfeng
    Quan, Wei
    Zhang, Weijia
    Xing, Li
    Liu, Gang
    IEEE ACCESS, 2019, 7 : 28574 - 28580
  • [7] Measuring Spin Polarization of a Spin-Exchange Relaxation-Free Atomic Magnetometer at Extremely Large Optical Depths
    Ma, Yanning
    Lu, Jixi
    Yang, Ke
    Wang, Zixuan
    Wang, Yaoguo
    Sun, Bowen
    Zhai, Yueyang
    Han, Bangcheng
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2022, 71
  • [8] Spin-exchange relaxation-free magnetometer with nearly parallel pump and probe beams
    Karaulanov, Todor
    Savukov, Igor
    Kim, Young Jin
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2016, 27 (05)
  • [9] Search for exotic spin-dependent interactions with a spin-exchange relaxation-free magnetometer
    Chu, P. -H.
    Kim, Y. J.
    Savukov, I.
    PHYSICAL REVIEW D, 2016, 94 (03)
  • [10] Miniature quad-channel spin-exchange relaxation-free magnetometer for magnetoencephalography
    Li, Jian-Jun
    Du, Peng-Cheng
    Fu, Ji-Qing
    Wang, Xu-Tong
    Zhou, Qing
    Wang, Ru-Quan
    CHINESE PHYSICS B, 2019, 28 (04)