A theory and design of an insulating insert in a cathodically protected underground water pipeline. II. The corrosion rate of anodic zones and effectiveness of the insert

被引:1
|
作者
Freiman, LI [1 ]
机构
[1] Pamfilov Acad Municiapl Serv, Moscow 123371, Russia
来源
PROTECTION OF METALS | 2002年 / 38卷 / 03期
关键词
Inorganic Chemistry; Corrosion Rate; Influence Factor; Underground Water; Cathodically Protect;
D O I
10.1023/A:1015625607163
中图分类号
TF [冶金工业];
学科分类号
0806 ;
摘要
As a continuation of the previous study [1], the current flowing through an insulating tubular insert is calculated for a cathodically protected, underground water pipeline. The solution obtained allows calculating the anodic corrosion rate inside a pipe adjacent to the insert, as well as the insert's effectiveness. The main regularities in changing in the above parameters, as well as influencing factors are revealed.