Validity of combining heart rate and uniaxial acceleration to measure free-living physical activity energy expenditure in young men

被引:70
作者
Villars, C. [1 ]
Bergouignan, A. [2 ,3 ]
Dugas, J. [1 ]
Antoun, E. [1 ,2 ]
Schoeller, D. A. [4 ]
Roth, H. [5 ]
Maingon, A. C. [1 ]
Lefai, E. [1 ]
Blanc, S. [2 ]
Simon, C. [1 ]
机构
[1] Univ Lyon 1, Carmen Inserm U1060, INRA U1235, CRNH Rhone Alpes, F-69365 Lyon, France
[2] Univ Strasbourg, Hubert Curien Pluridisciplinary Inst, Dept Ecol Physiol & Ethol, UMR CNRS 7178, Strasbourg, France
[3] Univ Colorado Denver, Ctr Human Nutr, Aurora, CO USA
[4] Univ Wisconsin, Dept Nutr Sci, Madison, WI 53706 USA
[5] Univ Grenoble, Grenoble Univ Hosp, Inserm U1055, Grenoble, France
关键词
exercise; body movement; heart rate; accelerometer; doubly labeled water; DOUBLY LABELED WATER; BODY-COMPOSITION; ADULTS; INTENSITY; ACCELEROMETER; ACTIHEART; ACCURACY; MOVEMENT; RELIABILITY; HUMANS;
D O I
10.1152/japplphysiol.01413.2011
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Villars C, Bergouignan A, Dugas J, Antoun E, Schoeller DA, Roth H, Maingon AC, Lefai E, Blanc S, Simon C. Validity of combining heart rate and uniaxial acceleration to measure free-living physical activity energy expenditure in young men. J Appl Physiol 113: 1763-1771, 2012. First published September 27, 2012; doi:10.1152/japplphysiol.01413.2011.-Combining accelerometry (ACC) with heart rate (HR) monitoring is thought to improve activity energy expenditure (AEE) estimations compared with ACC alone to evaluate the validity of ACC and HR used alone or combined. The purpose of this study was to estimate AEE in free-living conditions compared with doubly labeled water (DLW). Ten-day free-living AEE was measured by a DLW protocol in 35 18- to 55-yr-old men (11 lean active; 12 lean sedentary; 12 overweight sedentary) wearing an Actiheart (combining ACC and HR) and a RT3 accelerometer. AEE was estimated using group or individual calibration of the HR/AEE relationship, based on an exercise-tolerance test. In a subset (n = 21), AEE changes (Delta AEE) were measured after 1 mo of detraining (active subjects) or an 8-wk training (sedentary subjects). Actiheart-combined ACC/HR estimates were more accurate than estimates from HR or ACC alone. Accuracy of the Actiheart group-calibrated ACC/HR estimates was modest [intraclass correlation coefficient (ICC) = 0.62], with no bias but high root mean square error (RMSE) and limits of agreement (LOA). The mean bias of the estimates was reduced by one-third, like RMSE and LOA, by individual calibration (ICC = 0.81). Contrasting with group-calibrated estimates, the Actiheart individual-calibrated ACC/HR estimates explained 40% of the variance of the DLW-Delta AEE (ICC = 0.63). This study supports a good level of agreement between the Actiheart ACC/HR estimates and DLW-measured AEE in lean and overweight men with varying fitness levels. Individual calibration of the HR/AEE relationship is necessary for AEE estimations at an individual level rather than at group scale and for Delta AEE evaluation.
引用
收藏
页码:1763 / 1771
页数:9
相关论文
共 38 条
  • [1] Accuracy and validity of a combined heart rate and motion sensor for the measurement of free-living physical activity energy expenditure in adults in Cameroon
    Assah, Felix K.
    Ekelund, Ulf
    Brage, Soren
    Wright, Antony
    Mbanya, Jean Claude
    Wareham, Nicholas J.
    [J]. INTERNATIONAL JOURNAL OF EPIDEMIOLOGY, 2011, 40 (01) : 112 - 120
  • [2] Barreira TV, 2009, INT J EXERC SCI, V2, P60
  • [3] Blanc S, 2004, AM J CLIN NUTR, V79, P303
  • [4] Influence of delayed isotopic equilibration in urine on the accuracy of the 2H2 18O method in the elderly
    Blanc, S
    Colligan, AS
    Trabulsi, J
    Harris, T
    Everhart, JE
    Bauer, D
    Schoeller, DA
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 2002, 92 (03) : 1036 - 1044
  • [5] Fuel homeostasis during physical inactivity induced by bed rest
    Blanc, S
    Normand, S
    Pachiaudi, C
    Fortrat, JO
    Laville, M
    Gharib, C
    [J]. JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2000, 85 (06) : 2223 - +
  • [6] REGRESSION-ANALYSIS
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8486) : 908 - 909
  • [7] Advances in physical activity monitoring and lifestyle interventions in obesity: a review
    Bonomi, A. G.
    Westerterp, K. R.
    [J]. INTERNATIONAL JOURNAL OF OBESITY, 2012, 36 (02) : 167 - 177
  • [8] Improving assessment of daily energy expenditure by identifying types of physical activity with a single accelerometer
    Bonomi, A. G.
    Plasqui, G.
    Goris, A. H. C.
    Westerterp, K. R.
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 2009, 107 (03) : 655 - 661
  • [9] Effect of combined movement and heart rate monitor placement on physical activity estimates during treadmill locomotion and free-living
    Brage, S
    Brage, N
    Ekelund, U
    Luan, J
    Franks, PW
    Froberg, K
    Wareham, NJ
    [J]. EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2006, 96 (05) : 517 - 524
  • [10] Reliability and validity of the combined heart rate and movement sensor Actiheart
    Brage, S
    Brage, N
    Franks, PW
    Ekelund, U
    Wareham, NJ
    [J]. EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2005, 59 (04) : 561 - 570