Accuracy, agreement, and reliability of DECT-derived vBMD measurements: an initial ex vivo study

被引:8
作者
Qin, Le [1 ]
Huang, Jingjing [2 ]
Yu, Pei [2 ]
Yan, Jing [3 ]
Ge, Yingqian [3 ]
Lu, Yong [1 ]
Yan, Fuhua [1 ]
Wang, Lei [2 ]
Du, Lianjun [1 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Med, Ruijin Hosp, Dept Radiol, 197 Ruijin 2nd Rd, Shanghai 200025, Peoples R China
[2] Shanghai Jiao Tong Univ, Sch Med, Ruijin Hosp, Dept Orthoped, 197 Ruijin 2nd Rd, Shanghai 200025, Peoples R China
[3] Siemens Healthcare Ltd, 278 Zhouzhu Rd, Shanghai 201318, Peoples R China
关键词
Tomography; X-ray computed; Dual-energy X-ray absorptiometry scan; Bone density; Calibration; DUAL-ENERGY CT; BONE-MINERAL DENSITY; QUANTIFICATION; SPINE;
D O I
10.1007/s00330-020-07118-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives To assess the agreement and reliability of DECT (dual-energy CT)-derived vBMD (volumetric bone mineral density) measurements from excised human femoral heads and to compare DECT-derived BMD with that measured by DXA (dual-energy X-ray absorptiometry) and QCT (quantitative CT) to determine its accuracy. Methods Twenty patients that underwent total hip arthroplasty were enrolled to this study. Femoral heads were excised to rectangles without cortical bones for scanning. A dual-source DECT scanner generated images under 80/Sn140 kVp and 100/Sn140 kVp scanning conditions. Specimens were subsequently scanned by QCT and DXA to produce QCT-derived vBMD (mg/cm(3)) and DXA-derived BMM (bone mineral mass, g). DECT images were loaded to a post-processing workstation to calculate DECT-derived vBMD and BMM. Results Higher DECT-derived vBMD and BMM were found under 80/Sn140 and 100/Sn140 kVp compared with those for QCT and DXA (p = 0.005). DECT-derived vBMD was highly correlated with QCT-derived vBMD (r = 0.961 similar to 0.993,p < 0.05). Similarly, DECT-derived BMM was strongly correlated with DXA-derived BMM (r = 0.927 similar to 0.943,p < 0.05). Agreement of the inter- and intra-observation of DECT-derived vBMD was excellent. Linear regression was carried out to calibrate DECT-derived vBMD of 80/Sn140 kVp (14 + 0.7 x DECT-derived vBMD) and 100/Sn140 kVp (74 + 0.4 x DECT-derived vBMD) with the reference of QCT-derived vBMD. After calibration, excellent agreement was found for vBMD and BMM within various imaging modalities. Conclusions Our study showed that DECT-derived vBMD exhibited high agreement and reliability features, and after calibration, it also displayed a high degree of accuracy. However, in vivo studies are needed to extend its potential utility in clinical settings.
引用
收藏
页码:191 / 199
页数:9
相关论文
共 26 条
[1]  
American College of Radiology, 2018, ACR SPR SSR PRACT PA
[2]   Association between bone indices assessed by DXA, HR-pQCT and QCT scans in post-menopausal women [J].
Amstrup, Anne Kristine ;
Jakobsen, Niels Frederik Breum ;
Moser, Emil ;
Sikjaer, Tanja ;
Mosekilde, Leif ;
Rejnmark, Lars .
JOURNAL OF BONE AND MINERAL METABOLISM, 2016, 34 (06) :638-645
[3]   Bone Mineral Density Among Men and Women Aged 35 to 50 Years [J].
Bass, Martha A. ;
Sharma, Ankita ;
Nahar, Vinayak K. ;
Chelf, Stacy ;
Zeller, Brittany ;
Pham, Linda ;
Ford, M. Allison .
JOURNAL OF THE AMERICAN OSTEOPATHIC ASSOCIATION, 2019, 119 (06) :357-363
[4]   Postmenopausal Osteoporosis [J].
Black, Dennis M. ;
Rosen, Clifford J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2016, 374 (03) :254-262
[5]   Evaluation of bone mineral density of the lumbar spine using a novel phantomless dual-energy CT post-processing algorithm in comparison with dual-energy X-ray absorptiometry [J].
Booz C. ;
Hofmann P.C. ;
Sedlmair M. ;
Flohr T.G. ;
Schmidt B. ;
D’Angelo T. ;
Martin S.S. ;
Lenga L. ;
Leithner D. ;
Vogl T.J. ;
Wichmann J.L. .
European Radiology Experimental, 1 (1)
[6]   Marrow Adipose Tissue Quantification of the Lumbar Spine by Using Dual-Energy CT and Single-Voxel 1H MR Spectroscopy: A Feasibility Study [J].
Bredella, Miriam A. ;
Daley, Scott M. ;
Kalra, Mannudeep K. ;
Brown, J. Keenan ;
Miller, Karen K. ;
Torriani, Martin .
RADIOLOGY, 2015, 277 (01) :230-235
[7]   Prevalence of osteoporosis in China: a meta-analysis and systematic review [J].
Chen, Peng ;
Li, Zhanzhan ;
Hu, Yihe .
BMC PUBLIC HEALTH, 2016, 16 :1-11
[8]   QCT-based finite element models predict human vertebral strength in vitro significantly better than simulated DEXA [J].
Dall'Ara, E. ;
Pahr, D. ;
Varga, P. ;
Kainberger, F. ;
Zysset, P. .
OSTEOPOROSIS INTERNATIONAL, 2012, 23 (02) :563-572
[9]   Advanced CT based In Vivo Methods for the Assessment of Bone Density, Structure, and Strength [J].
Engelke, K. ;
Libanati, C. ;
Fuerst, T. ;
Zysset, P. ;
Genant, H. K. .
CURRENT OSTEOPOROSIS REPORTS, 2013, 11 (03) :246-255
[10]   Induction of osteoporosis with its influence on osteoporotic determinants and their interrelationships in rats by DEXA [J].
Heiss, Christian ;
Govindarajan, Parameswari ;
Schlewitz, Gudrun ;
Hemdan, Nasr Y. A. ;
Schliefke, Nathalie ;
Alt, Volker ;
Thormann, Ulrich ;
Lips, Katrin Susanne ;
Wenisch, Sabine ;
Langheinrich, Alexander C. ;
Zahner, Daniel ;
Schnettler, Reinhard .
MEDICAL SCIENCE MONITOR, 2012, 18 (06) :BR199-BR207