Determination of heart rate variability with an electronic stethoscope

被引:8
作者
Kamran, Haroon [1 ]
Naggar, Isaac [2 ]
Oniyuke, Francisca [1 ]
Palomeque, Mercy [1 ]
Chokshi, Priya [1 ]
Salciccioli, Louis [1 ]
Stewart, Mark [2 ]
Lazar, Jason M. [1 ]
机构
[1] Suny Downstate Med Ctr, Div Cardiovasc Med, Brooklyn, NY 11203 USA
[2] Suny Downstate Med Ctr, Dept Physiol & Pharmacol, Brooklyn, NY 11203 USA
关键词
Heart rate variability; Electronic stethoscope; Autonomic function; Physical examination; SYSTOLIC-TIME INTERVALS; SHORT-TERM MEASUREMENTS; AUSCULTATION;
D O I
10.1007/s10286-012-0177-3
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Heart rate variability (HRV) is widely used to characterize cardiac autonomic function by measuring beat-to-beat alterations in heart rate. Decreased HRV has been found predictive of worse cardiovascular (CV) outcomes. HRV is determined from time intervals between QRS complexes recorded by electrocardiography (ECG) for several minutes to 24 h. Although cardiac auscultation with a stethoscope is performed routinely on patients, the human ear cannot detect heart sound time intervals. The electronic stethoscope digitally processes heart sounds, from which cardiac time intervals can be obtained. Accordingly, the objective of this study was to determine the feasibility of obtaining HRV from electronically recorded heart sounds. We prospectively studied 50 subjects with and without CV risk factors/disease and simultaneously recorded single lead ECG and heart sounds for 2 min. Time and frequency measures of HRV were calculated from R-R and S1-S1 intervals and were compared using intra-class correlation coefficients (ICC). The majority of the indices were strongly correlated (ICC 0.73-1.0), while the remaining indices were moderately correlated (ICC 0.56-0.63). In conclusion, we found HRV measures determined from S1-S1 are in agreement with those determined by single lead ECG, and we demonstrate and discuss differences in the measures in detail. In addition to characterizing cardiac murmurs and time intervals, the electronic stethoscope holds promise as a convenient low-cost tool to determine HRV in the hospital and outpatient settings as a practical extension of the physical examination.
引用
收藏
页码:41 / 47
页数:7
相关论文
共 25 条
[1]   BEDSIDE MEASUREMENT OF SYSTOLIC AND DIASTOLIC TIME INTERVALS USING STETHOMETER [J].
ABELSON, D ;
KAMENS, EA .
CARDIOVASCULAR RESEARCH, 1977, 11 (03) :270-274
[2]   CURRENT CONCEPTS OF GENESIS OF HEART SOUNDS .1. 1ST AND 2ND SOUNDS [J].
ABRAMS, J .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1978, 239 (26) :2787-2789
[3]   The use of the Hilbert transform in ECG signal analysis [J].
Benitez, D ;
Gaydecki, PA ;
Zaidi, A ;
Fitzpatrick, AP .
COMPUTERS IN BIOLOGY AND MEDICINE, 2001, 31 (05) :399-406
[4]  
Camm AJ, 1996, EUR HEART J, V17, P354
[5]   Bedside prediction of increased filling pressure using acoustic electrocardiography [J].
Collins, Sean P. ;
Lindsell, Christopher J. ;
Kontos, Michael C. ;
Zuber, Michel ;
Kipfer, Peter ;
Jost, Christine Attenhofer ;
Kosmicki, Douglas ;
Michaels, Andrew D. .
AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2009, 27 (04) :397-408
[6]  
de Oliveira Neto NR, 2008, INTERNET J CARDIOL, V5, P2
[7]  
Erne P, 2008, SWISS MED WKLY, V138, P439, DOI 2008/31/smw-12308
[8]   Time intervals and global cardiac function. Use and limitations [J].
Gillebert, TC ;
de Veire, NV ;
De Buyzere, ML ;
De Sutter, J .
EUROPEAN HEART JOURNAL, 2004, 25 (24) :2185-2186
[9]   Heart rate variability: Measurement and clinical utility [J].
Kleiger, RE ;
Stein, PK ;
Bigger, JT .
ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, 2005, 10 (01) :88-101
[10]   Short-term heart rate variability in healthy young adults The Cardiovascular Risk in Young Finns Study [J].
Koskinen, Tuomas ;
Kahonen, Mika ;
Jula, Antti ;
Laitinen, Tomi ;
Jarvinen, Liisa Keltikangas ;
Viikari, Jorma ;
Valimaki, Ilkka ;
Raitakari, Olli T. .
AUTONOMIC NEUROSCIENCE-BASIC & CLINICAL, 2009, 145 (1-2) :81-88