Performance of Transient Elastography for the Staging of Liver Fibrosis in Patients with Chronic Hepatitis B: A Meta-Analysis

被引:223
作者
Chon, Young Eun [1 ,2 ]
Choi, Eun Hee [4 ]
Song, Ki Jun [4 ]
Park, Jun Yong [1 ,2 ,3 ]
Kim, Do Young [1 ,2 ,3 ]
Han, Kwang-Hyub [1 ,2 ,3 ]
Chon, Chae Yoon [1 ,2 ,3 ]
Ahn, Sang Hoon [1 ,2 ,3 ]
Kim, Seung Up [1 ,2 ,3 ]
机构
[1] Yonsei Univ, Coll Med, Dept Internal Med, Seoul, South Korea
[2] Yonsei Univ, Coll Med, Inst Gastroenterol, Seoul, South Korea
[3] Liver Cirrhosis Clin Res Ctr, Seoul, South Korea
[4] Yonsei Univ, Coll Med, Dept Biostat, Seoul, South Korea
关键词
STIFFNESS MEASUREMENT; NONINVASIVE ASSESSMENT; CIRRHOSIS; DIAGNOSIS; ACCURACY; BIOPSY; VARIABILITY; THERAPY; PREDICT; UPDATE;
D O I
10.1371/journal.pone.0044930
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background: Transient elastography (TE), a non-invasive tool that measures liver stiffness, has been evaluated in meta-analyses for effectiveness in assessing liver fibrosis in European populations with chronic hepatitis C(CHC). However, these data cannot be extrapolated to populations in Asian countries, where chronic hepatitis B(CHB) is more prevalent. In this study, we performed a meta-analysis to assess the overall performance of TE for assessing liver fibrosis in patients with CHB. Methods: Studies from the literature and international conference abstracts which enrolled only patients with CHB or performed a subgroup analysis of such patients were enrolled. Combined effects were calculated using area under the receiver operating characteristic curves (AUROC) and diagnostic accuracy values of each study. Result: A total of 18 studies comprising 2,772 patients were analyzed. The mean AUROCs for the diagnosis of significant fibrosis (F2), severe fibrosis (F3), and cirrhosis (F4) were 0.859 (95% confidence interval [CI], 0.857-0.860), 0.887 (95% CI, 0.886-0.887), and 0.929 (95% CI, 0.928-0.929), respectively. The estimated cutoff for F2 was 7.9 (range, 6.1-11.8) kPa, with a sensitivity of 74.3% and specificity of 78.3%. For F3, the cutoff value was determined to be 8.8 (range, 8.1-9.7) kPa, with a sensitivity of 74.0% and specificity of 63.8%. The cutoff value for F4 was 11.7 (range, 7.3-17.5) kPa, with a sensitivity of 84.6% and specificity of 81.5%. Conclusion: TE can be performed with good diagnostic accuracy for quantifying liver fibrosis in patients with CHB.
引用
收藏
页数:7
相关论文
共 56 条
[1]   Sampling variability of liver fibrosis in chronic hepatitis C [J].
Bedossa, P ;
Dargère, D ;
Paradis, V .
HEPATOLOGY, 2003, 38 (06) :1449-1457
[2]   Current concepts: Liver biopsy. [J].
Bravo, AA ;
Sheth, SG ;
Chopra, S .
NEW ENGLAND JOURNAL OF MEDICINE, 2001, 344 (07) :495-500
[3]   Prospective comparison of transient elastography, fibrotest, APRI, and liver biopsy for the assessment of fibrosis in chronic hepatitis C [J].
Castéra, L ;
Vergniol, J ;
Foucher, J ;
Le Bail, B ;
Chanteloup, E ;
Haaser, M ;
Darriet, M ;
Couzigou, P ;
De Lédinghen, V .
GASTROENTEROLOGY, 2005, 128 (02) :343-350
[4]  
Castera L, 2009, HEPATOLOGY, V50, p978A
[5]   Alanine aminotransferase-based algorithms of liver stiffness measurement by transient elastography (Fibroscan) for liver fibrosis in chronic hepatitis B [J].
Chan, H. L. -Y. ;
Wong, G. L. -H. ;
Choi, P. C. -L. ;
Chan, A. W. -H. ;
Chim, A. M. -L. ;
Yiu, K. K. -L. ;
Chan, F. K. -L. ;
Sung, J. J. -Y. ;
Wong, V. W. -S. .
JOURNAL OF VIRAL HEPATITIS, 2009, 16 (01) :36-44
[6]  
Chang J, 2006, HEPATOL INT, V1, P785
[7]  
Chang J, 2009, HEPATOLOGY, V50, p501A
[8]  
Chen Y, 2011, HEPATOL INT, V54, P304
[9]   The effect of lamivudine therapy in hepatic decompensation during acute exacerbation of chronic hepatitis B [J].
Chien, RN ;
Lin, CH ;
Liaw, YF .
JOURNAL OF HEPATOLOGY, 2003, 38 (03) :322-327
[10]  
Choi JW, 2008, HEPATOLOGY, V48, p750A