Reproducibility of computed tomography angiography data analysis using semiautomated plaque quantification software: implications for the design of longitudinal studies

被引:50
作者
Papadopoulou, Stella-Lida [1 ,2 ]
Garcia-Garcia, Hector M. [1 ]
Rossi, Alexia [1 ,2 ]
Girasis, Chrysafios [1 ]
Dharampal, Anoeshka S. [1 ,2 ]
Kitslaar, Pieter H. [3 ]
Krestin, Gabriel P. [2 ]
de Feyter, Pim J. [1 ,2 ]
机构
[1] Erasmus Univ, Dept Cardiol, Med Ctr, NL-3000 CA Rotterdam, Netherlands
[2] Erasmus Univ, Dept Radiol, Med Ctr, NL-3000 CA Rotterdam, Netherlands
[3] Leiden Univ, Div Image Proc, Dept Radiol, Med Ctr, Leiden, Netherlands
关键词
Agreement; Atherosclerosis; Computed tomography angiography; Plaque quantification; Reproducibility; ACUTE CORONARY SYNDROME; INTRAVASCULAR ULTRASOUND; ATHEROSCLEROSIS; PROGRESSION; REGRESSION; ARTERIES; THERAPY;
D O I
10.1007/s10554-012-0167-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Reproducibility of the quantitative assessment of atherosclerosis by computed tomography coronary angiography (CTCA) is paramount for the design of longitudinal studies. The purpose of this study was to assess the inter- and intra-observer reproducibility using semiautomated CT plaque analysis software in symptomatic individuals. CTCA was performed in 10 symptomatic patients after percutaneous treatment of the culprit lesions and was repeated after 3 years. The plaque quantitative analysis was performed in untreated vessels with mild-to-moderate atherosclerosis and included geometrical and compositional characteristics using semiautomated CT plaque analysis software. A total of 945 matched cross-sections from 21 segments were analyzed independently by a second reviewer to assess inter-observer variability; the first observer repeated all the analyses after 3 months to assess intra-observer variability. The observer variability was also compared to the absolute plaque changes detected over time. Agreement was evaluated by Bland-Altman analysis and concordance correlation coefficient. Inter-observer relative differences for lumen, vessel, plaque area and plaque burden were 1.2, 0.6, 2.2, 1.6 % respectively. Intra-observer relative differences for lumen, vessel, plaque area and plaque burden were 1.0, 0.4, 0.2, 0.4 % respectively. For the average plaque attenuation values the inter- and intra-observer variability was 5 and 2 % respectively. For the % low-attenuation-plaque the inter- and intra-observer variability was 16 and 6 % respectively. The absolute intra-observer variability for the plaque burden was 1.30 +/- A 1.09 %, while the temporal plaque burden difference was 3.55 +/- A 3.02 % (p = 0.001). The present study shows that the geometrical assessment of coronary atherosclerosis by CTCA is highly reproducible within and between observers using semiautomated quantification software and that serial plaque changes can be detected beyond observer variability. The compositional measurements are more variable between observers than geometrical measurements.
引用
收藏
页码:1095 / 1104
页数:10
相关论文
共 22 条
[1]  
Austen W G, 1975, Circulation, V51, P5
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]  
BONGARTZ G, 2004, CT QUALITY CRITERIA
[4]   Automated quantification of coronary plaque with computed tomography: comparison with intravascular ultrasound using a dedicated registration algorithm for fusion-based quantification [J].
Boogers, Mark J. ;
Broersen, Alexander ;
van Velzen, Joella E. ;
de Graaf, Fleur R. ;
El-Naggar, Heba M. ;
Kitslaar, Pieter H. ;
Dijkstra, Jouke ;
Delgado, Victoria ;
Boersma, Eric ;
de Roos, Albert ;
Schuijf, Joanne D. ;
Schalij, Martin J. ;
Reiber, Johan H. C. ;
Bax, Jeroen J. ;
Jukema, J. Wouter .
EUROPEAN HEART JOURNAL, 2012, 33 (08) :1007-1016
[5]   Influence of a lipid-lowering therapy on calcified and noncalcified coronary plaques monitored by multislice detector computed tomography - Results of the New Age II pilot study [J].
Burgstahler, Christof ;
Reimann, Anja ;
Beck, Torsten ;
Kuettner, Axel ;
Baumann, Dorothee ;
Heuschmid, Martin ;
Brodoefel, Harald ;
Claussen, Claus D. ;
Kopp, Andreas F. ;
Schroeder, Stephen .
INVESTIGATIVE RADIOLOGY, 2007, 42 (03) :189-195
[6]   QUANTITATIVE CORONARY ANGIOGRAPHY TO MEASURE PROGRESSION AND REGRESSION OF CORONARY ATHEROSCLEROSIS - VALUE, LIMITATIONS, AND IMPLICATIONS FOR CLINICAL-TRIALS [J].
DEFEYTER, PJ ;
SERRUYS, PW ;
DAVIES, MJ ;
RICHARDSON, P ;
LUBSEN, J ;
OLIVER, MF .
CIRCULATION, 1991, 84 (01) :412-423
[7]   Reproducibility of volumetric intravascular ultrasound radiofrequency-based analysis of coronary plaque composition in vivo [J].
Hartmann, Marc ;
Mattern, Eline S. K. ;
Huisman, Jennifer ;
van Houwelingen, Gert K. ;
de Man, Frits H. A. F. ;
Stoel, Martin G. ;
Danse, Peter W. ;
Louwerenburg, Hans W. ;
von Birgelen, Clemens .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2009, 25 (01) :13-23
[8]   Reproducibility of Intravascular Ultrasound iMAP for Radiofrequency Data Analysis: Implications for Design of Longitudinal Studies [J].
Heo, Jung Ho ;
Brugaletta, Salvatore ;
Garcia-Garcia, Hector M. ;
Gomez-Lara, Josep ;
Ligthart, Jurgen M. R. ;
Witberg, Karen ;
Magro, Michael ;
Shin, Eun-Seok ;
Serruys, Patrick W. .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2014, 83 (07) :E233-E242
[9]   Influence of statin treatment on coronary atherosclerosis visualised using multidetector computed tomography [J].
Hoffmann, Hans ;
Frieler, Katja ;
Schlattmann, Peter ;
Hamm, Bernd ;
Dewey, Marc .
EUROPEAN RADIOLOGY, 2010, 20 (12) :2824-2833
[10]   Serial Coronary CT Angiography-Verified Changes in Plaque Characteristics as an End Point Evaluation of Effect of Statin Intervention [J].
Inoue, Kaori ;
Motoyama, Sadako ;
Sarai, Masayoshi ;
Sato, Takahisa ;
Harigaya, Hiroto ;
Hara, Tomonori ;
Sanda, Yoshihiro ;
Anno, Hirofumi ;
Kondo, Takeshi ;
Wong, Nathan D. ;
Narula, Jagat ;
Ozaki, Yukio .
JACC-CARDIOVASCULAR IMAGING, 2010, 3 (07) :691-698