摘要
Introduction: Two factors affect the choice of instruments for root canal preparation: its ability to achieve the canal's shaping and its safety. These factors depend on the profile of the instrument and the design of its active part. In this study, we tried to assess the role of an asymmetric cross-section on the behavior of the instrument by measuring the stresses generated during the preparation of a simulated canal. Methods: Three 25-mm-long, 0.06 taper, ISO size #30 helical nickel-titaniufn instruments were tested. The first HerShaper (Micro-Mega, Besancon, France) used had a symmetric triple helix section (HO). The others, based on the HeroShaper design, had a constant asymmetry of 4/100 mm (H4) or 6/100 mm (H6). Six canals were prepared using each instrument, and the experimental conditions (ie, speed and movement) were the same for each sample. A dynamometer with a sensitivity of 0.1 N recorded the stresses transmitted by the instruments. Results: Torque and apical force increased proportionally with instrument penetration. At the end of the preparations, the axial stress averaged 7.39 N for the symmetric instrument and 5.92 and 5.15 N for the asymmetric instruments, which indicated a significant statistical analysis of variance (P <.001). The average torque was low (1.05-1.13 N.cm), which indicated a nonsignificant statistical analysis of variance (P =.2385). Conclusions: In this study, axial stresses decreased, but torque did not change with an asymmetric triple helix cross-section.
引用
收藏
页码:829 / 832
页数:4
相关论文
共 19 条
[1]   Comparative analysis of torsional and bending behavior through finite-element models of 5 Ni-Ti endodontic instruments [J].
Arbab-Chirani, Reza ;
Chevalier, Valerie ;
Arbab-Chirani, Shabnam ;
Calloch, Sylvain .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2011, 111 (01) :115-121
[2]   A three-dimensional model describing stress-temperature induced solid phase transformations: thermomechanical coupling and hybrid composite applications [J].
Auricchio, F ;
Petrini, L .
INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN ENGINEERING, 2004, 61 (05) :716-737
[3]   Shape-memory alloys: Macromodelling and numerical simulations of the superelastic behavior [J].
Auricchio, F ;
Taylor, RL ;
Lubliner, J .
COMPUTER METHODS IN APPLIED MECHANICS AND ENGINEERING, 1997, 146 (3-4) :281-312
[4]   Comparative analysis of torsional and bending stresses in two mathematical models of nickel-titanium rotary instruments: ProTaper versus ProFile [J].
Berutti, E ;
Chiandussi, G ;
Gaviglio, I ;
Ibba, A .
JOURNAL OF ENDODONTICS, 2003, 29 (01) :15-19
[5]   Mechanical behavior of a Cu-Al-Be shape memory alloy under multiaxial proportional and nonproportional loadings [J].
Bouvet, C ;
Calloch, S ;
Lexcellent, C .
JOURNAL OF ENGINEERING MATERIALS AND TECHNOLOGY-TRANSACTIONS OF THE ASME, 2002, 124 (02) :112-124
[6]  
Calas P, 2005, ENDOD TOP, V10, P155
[7]   An improved model of 3-dimensional finite element analysis of mechanical behavior of endodontic instruments [J].
Chevalier, Valerie ;
Arbab-Chirani, Reza ;
Arbab-Chirani, Shabnam ;
Calloch, Sylvain .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2010, 109 (03) :E111-E121
[8]   Effect of pitch length on the behavior of rotary triple helix root canal instruments [J].
Diemer, F ;
Calas, P .
JOURNAL OF ENDODONTICS, 2004, 30 (10) :716-718
[9]   A Novel Platform for In Vitro Analysis of Torque, Forces, and Three-dimensional File Displacements During Root Canal Preparations: Application to ProTaper Rotary Files [J].
Diop, Amadou ;
Maurel, Nathalie ;
Oiknine, Michel ;
Patoor, Etienne ;
Machtou, Pierre .
JOURNAL OF ENDODONTICS, 2009, 35 (04) :568-572
[10]   Comparison of forces generated during root canal shaping and residual stresses of three nickel-titanium rotary files by using a three-dimensional finite-element analysis [J].
Kim, Hyeon-Cheol ;
Shun-Pan, Gary ;
Lee, Chan-Joo ;
Kim, Byung-Min ;
Park, Jeong-Kil ;
Kang, Soon-Il .
JOURNAL OF ENDODONTICS, 2008, 34 (06) :743-747