Anti-adhesive antimicrobial peptide coating prevents catheter associated infection in a mouse urinary infection model

被引:219
作者
Yu, Kai [1 ]
Lo, Joey C. Y. [2 ]
Yan, Mei [1 ]
Yang, Xiaoqiang [1 ]
Brooks, Donald E. [1 ,3 ]
Hancock, Robert E. W. [4 ]
Lange, Dirk [2 ]
Kizhakkedathu, Jayachandran N. [1 ,3 ]
机构
[1] Univ British Columbia, Dept Pathol & Lab Med, Ctr Blood Res, Vancouver, BC V6T 1Z3, Canada
[2] Univ British Columbia, Dept Urol Sci, Vancouver, BC V5Z 1M9, Canada
[3] Univ British Columbia, Dept Chem, Vancouver, BC V6T 1Z3, Canada
[4] Univ British Columbia, Ctr Microbial Dis & Immun Res, Dept Microbiol & Immunol, Vancouver, BC V6T 1Z4, Canada
基金
加拿大自然科学与工程研究理事会; 加拿大健康研究院;
关键词
Catheter-associated urinary tract infections; Urinary infection model; Antimicrobial peptide; Polymer brush coating; Biocompatibility; CARE-ASSOCIATED INFECTIONS; COATED FOLEY CATHETERS; TRACT-INFECTION; POLYMER BRUSHES; DISEASES-SOCIETY; IMMOBILIZATION; RESISTANT; SURFACES; EFFICACY; DENSITY;
D O I
10.1016/j.biomaterials.2016.11.047
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Catheter-associated urinary tract infections (CAUTIs) represent one of the most common hospital acquired infections with significant economic consequences and increased patient morbidity. CAUTIs often start with pathogen adhesion and colonization on the catheter surface followed by biofilm formation. Current strategies to prevent CAUTIs are insufficiently effective and antimicrobial coatings based on antimicrobial peptides (AMPs) hold promise in curbing CAUTIs. Here we report an effective surface tethering strategy to, prepare AMP coatings on polyurethane (PU), a common biomedical plastic used for catheter manufacture, by using an anti-adhesive hydrophilic polymer coating. An optimized surface active AMP, labeled with cysteine at the C-terminus (RRWRIVVIRVRRC), was used. The coated PU surface was characterized using ATR-FTIR, XPS and atomic force microscopy analyses. The tethered peptides on the PU catheter surface displayed broad spectrum antimicrobial activity and showed long term activity in vitro. The surface coating prevented bacterial adhesion by up to 99.9% for both Gram-positive and -negative bacteria, and inhibited planktonic bacterial growth by up to 70%. In vivo, the coating was tested in a mouse urinary catheter infection model; the AMP-coated PU catheter was able to prevent infection with high efficiency by reducing the bacteria adhesion on catheter surface by more than 4 logs (from 1.2 x 10(6) CFU/mL to 5 x 10(1) CFU/mL) compared to the uncoated catheter surface, and inhibit planktonic bacterial growth in the urine by nearly 3 logs (1.1 x 10(7) CFU/mL to 1.47 x 10(4) CFU/mL). The AMP-brush coating also showed good biocompatibility with bladder epithelial cells and fibroblast cells in cell culture. The new coating might find clinical applications in preventing CAUTIs. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:69 / 81
页数:13
相关论文
共 59 条
[51]  
Theodoros K., 2011, URINARY TRACT IMMUNO
[52]   Phase 2 clinical trial of a vaginal mucosal vaccine for urinary tract infections [J].
Uehling, DT ;
Hopkins, WJ ;
Elkahwaji, JE ;
Schmidt, DM ;
Leverson, GE .
JOURNAL OF UROLOGY, 2003, 170 (03) :867-869
[53]   Efficacy of antiseptic-impregnated central venous catheters in preventing catheter-related bloodstream infection - A meta-analysis [J].
Veenstra, DL ;
Saint, S ;
Saha, S ;
Lumley, T ;
Sullivan, SD .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1999, 281 (03) :261-267
[54]   Incidence of Catheter-Associated and Non-Catheter-Associated Urinary Tract Infections in a Healthcare System [J].
Weber, David J. ;
Sickbert-Bennett, Emily E. ;
Gould, Carolyn V. ;
Brown, Vickie M. ;
Huslage, Kirk ;
Rutala, William A. .
INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2011, 32 (08) :822-823
[55]   A novel cationic-peptide coating for the prevention of microbial colonization on contact lenses [J].
Willcox, M. D. P. ;
Hume, E. B. H. ;
Aliwarga, Y. ;
Kumar, N. ;
Cole, N. .
JOURNAL OF APPLIED MICROBIOLOGY, 2008, 105 (06) :1817-1825
[56]   Toward Infection-Resistant Surfaces: Achieving High Antimicrobial Peptide Potency by Modulating the Functionality of Polymer Brush and Peptide [J].
Yu, Kai ;
Lo, Joey C. Y. ;
Mei, Yan ;
Haney, Evan F. ;
Siren, Erika ;
Kalathottukaren, Manu Thomas ;
Hancock, Robert E. W. ;
Lange, Dirk ;
Kizhakkedathu, Jayachandran N. .
ACS APPLIED MATERIALS & INTERFACES, 2015, 7 (51) :28591-28605
[57]   Interaction of blood components with cathelicidins and their modified versions [J].
Yu, Kai ;
Lai, Benjamin F. L. ;
Gani, Jurnorain ;
Mikut, Ralf ;
Hilpert, Kai ;
Kizhakkedathu, Jayachandran N. .
BIOMATERIALS, 2015, 69 :201-211
[58]   Health Care-Associated Infections A Meta-analysis of Costs and Financial Impact on the US Health Care System [J].
Zimlichman, Eyal ;
Henderson, Daniel ;
Tamir, Orly ;
Franz, Calvin ;
Song, Peter ;
Yamin, Cyrus K. ;
Keohane, Carol ;
Denham, Charles R. ;
Bates, David W. .
JAMA INTERNAL MEDICINE, 2013, 173 (22) :2039-2046
[59]   Barrier Capacity of Hydrophilic Polymer Brushes To Prevent Hydrophobic Interactions: Effect of Graft Density and Hydrophilicity [J].
Zou, Yuquan ;
Rossi, Nicholas A. A. ;
Kizhakkedathu, Jayachandran N. ;
Brooks, Donald E. .
MACROMOLECULES, 2009, 42 (13) :4817-4828