共 59 条
Anti-adhesive antimicrobial peptide coating prevents catheter associated infection in a mouse urinary infection model
被引:219
作者:
Yu, Kai
[1
]
Lo, Joey C. Y.
[2
]
Yan, Mei
[1
]
Yang, Xiaoqiang
[1
]
Brooks, Donald E.
[1
,3
]
Hancock, Robert E. W.
[4
]
Lange, Dirk
[2
]
Kizhakkedathu, Jayachandran N.
[1
,3
]
机构:
[1] Univ British Columbia, Dept Pathol & Lab Med, Ctr Blood Res, Vancouver, BC V6T 1Z3, Canada
[2] Univ British Columbia, Dept Urol Sci, Vancouver, BC V5Z 1M9, Canada
[3] Univ British Columbia, Dept Chem, Vancouver, BC V6T 1Z3, Canada
[4] Univ British Columbia, Ctr Microbial Dis & Immun Res, Dept Microbiol & Immunol, Vancouver, BC V6T 1Z4, Canada
来源:
基金:
加拿大自然科学与工程研究理事会;
加拿大健康研究院;
关键词:
Catheter-associated urinary tract infections;
Urinary infection model;
Antimicrobial peptide;
Polymer brush coating;
Biocompatibility;
CARE-ASSOCIATED INFECTIONS;
COATED FOLEY CATHETERS;
TRACT-INFECTION;
POLYMER BRUSHES;
DISEASES-SOCIETY;
IMMOBILIZATION;
RESISTANT;
SURFACES;
EFFICACY;
DENSITY;
D O I:
10.1016/j.biomaterials.2016.11.047
中图分类号:
R318 [生物医学工程];
学科分类号:
0831 ;
摘要:
Catheter-associated urinary tract infections (CAUTIs) represent one of the most common hospital acquired infections with significant economic consequences and increased patient morbidity. CAUTIs often start with pathogen adhesion and colonization on the catheter surface followed by biofilm formation. Current strategies to prevent CAUTIs are insufficiently effective and antimicrobial coatings based on antimicrobial peptides (AMPs) hold promise in curbing CAUTIs. Here we report an effective surface tethering strategy to, prepare AMP coatings on polyurethane (PU), a common biomedical plastic used for catheter manufacture, by using an anti-adhesive hydrophilic polymer coating. An optimized surface active AMP, labeled with cysteine at the C-terminus (RRWRIVVIRVRRC), was used. The coated PU surface was characterized using ATR-FTIR, XPS and atomic force microscopy analyses. The tethered peptides on the PU catheter surface displayed broad spectrum antimicrobial activity and showed long term activity in vitro. The surface coating prevented bacterial adhesion by up to 99.9% for both Gram-positive and -negative bacteria, and inhibited planktonic bacterial growth by up to 70%. In vivo, the coating was tested in a mouse urinary catheter infection model; the AMP-coated PU catheter was able to prevent infection with high efficiency by reducing the bacteria adhesion on catheter surface by more than 4 logs (from 1.2 x 10(6) CFU/mL to 5 x 10(1) CFU/mL) compared to the uncoated catheter surface, and inhibit planktonic bacterial growth in the urine by nearly 3 logs (1.1 x 10(7) CFU/mL to 1.47 x 10(4) CFU/mL). The AMP-brush coating also showed good biocompatibility with bladder epithelial cells and fibroblast cells in cell culture. The new coating might find clinical applications in preventing CAUTIs. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:69 / 81
页数:13
相关论文