Influence of Loading and Use of Occlusal Splint in Implant-Supported Fixed Prostheses

被引:14
作者
Teixeira, Fabiola Marchezini [1 ]
de Assis Claro, Cristiane Aparecida [1 ]
Claro Neves, Ana Christina [1 ]
Rode, Sigmar de Mello [2 ]
da Silva-Concilio, Lais Regiane [1 ]
机构
[1] Univ Taubate, Dept Prosthodont, Grad Program Dent, Sao Paulo, Brazil
[2] Univ State Sao Paulo, Dept Dent Mat, Sao Jose dos Campos Dent Coll, Sao Paulo, Brazil
关键词
Dental implant; fixed partial dentures; bruxism; photoelastic stress analysis; FINITE-ELEMENT-ANALYSIS; STRESS-DISTRIBUTION; OSSEOINTEGRATED IMPLANTS; SLEEP BRUXISM; BONE LOSS; 15-YEAR;
D O I
10.1097/SCS.0b013e31825aad82
中图分类号
R61 [外科手术学];
学科分类号
摘要
The aim of the study was to assess the tensions generated in the long axis of the implants and the interimplants in the cervical, middle, and apical regions when subjected to different loads with or without interposition of the flat occlusal plane splint. A photoelastic model was made with 2 external hexagon implants located in the space corresponding to the second premolar and molar inferiors. A screw-retained metal superstructure was installed on the implants with a torque of 20 N.cm, and the set (photoelastic model with superstructure) were positioned in the circular polariscope in the dark-field configuration to observe the distribution of isochromatic fringes around the implants and interimplant areas. Photographic records were obtained before the application of the occlusal load with the following loading conditions: 300, 600, and 900 N, with and without interposition of the occlusal plane splint. The decrease in stress with the application of the flat occlusal plane splint became more evident after the application of the 600-N load. Generally, the major stress magnitude occurred in the cervical region for interimplant areas and in the apical region around implants. Use of occlusal splint in the loading of 300, 600, and 900 N reduced tension 33.22%, 66.66%, and 73.33%, respectively, in the samples. It can be concluded that the interposition of the occlusal plane splint caused a reduction in tension resulting from the simulation of occlusal overload.
引用
收藏
页码:E477 / E480
页数:4
相关论文
共 28 条
  • [11] Force transmission of one- and two-piece morse-taper oral implants:: a nonlinear finite element analysis
    Çehreli, MC
    Akça, K
    Iplikçioglu, H
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2004, 15 (04) : 481 - 489
  • [12] Inflammation and Bone Loss in Periodontal Disease
    Cochran, David L.
    [J]. JOURNAL OF PERIODONTOLOGY, 2008, 79 (08) : 1569 - 1576
  • [13] Deines D N, 1993, Int J Periodontics Restorative Dent, V13, P540
  • [14] Esposito M, 1999, INT J ORAL MAX IMPL, V14, P473
  • [15] Effects of overdenture retention designs and implant orientations on load transfer characteristics
    Federick, DR
    Caputo, AA
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1996, 76 (06) : 624 - 632
  • [16] French A A, 1989, Int J Periodontics Restorative Dent, V9, P221
  • [17] Inan O, 1999, Implant Dent, V8, P311
  • [18] Bruxism physiology and pathology: an overview for clinicians
    Lavigne, G. J.
    Khoury, S.
    Abe, S.
    Yamaguchi, T.
    Raphael, K.
    [J]. JOURNAL OF ORAL REHABILITATION, 2008, 35 (07) : 476 - 494
  • [19] Photoelastic Analysis of Stress Distribution in Oral Rehabilitation
    Leal Turcio, Karina Helga
    Goiato, Marcelo Coelho
    Gennari Filho, Humberto
    dos Santos, Daniela Micheline
    [J]. JOURNAL OF CRANIOFACIAL SURGERY, 2009, 20 (02) : 471 - 474
  • [20] Evaluation of Stress Induced by Implant Type, Number of Splinted Teeth, and Variations in Periodontal Support in Tooth-Implant-Supported Fixed Partial Dentures: A Non-Linear Finite Element Analysis
    Lin, Chun-Li
    Wang, Jen-Chyan
    Chang, Shih-Hao
    Chen, Shiang-Ting
    [J]. JOURNAL OF PERIODONTOLOGY, 2010, 81 (01) : 121 - 130