Influence of Loading and Use of Occlusal Splint in Implant-Supported Fixed Prostheses

被引:14
作者
Teixeira, Fabiola Marchezini [1 ]
de Assis Claro, Cristiane Aparecida [1 ]
Claro Neves, Ana Christina [1 ]
Rode, Sigmar de Mello [2 ]
da Silva-Concilio, Lais Regiane [1 ]
机构
[1] Univ Taubate, Dept Prosthodont, Grad Program Dent, Sao Paulo, Brazil
[2] Univ State Sao Paulo, Dept Dent Mat, Sao Jose dos Campos Dent Coll, Sao Paulo, Brazil
关键词
Dental implant; fixed partial dentures; bruxism; photoelastic stress analysis; FINITE-ELEMENT-ANALYSIS; STRESS-DISTRIBUTION; OSSEOINTEGRATED IMPLANTS; SLEEP BRUXISM; BONE LOSS; 15-YEAR;
D O I
10.1097/SCS.0b013e31825aad82
中图分类号
R61 [外科手术学];
学科分类号
摘要
The aim of the study was to assess the tensions generated in the long axis of the implants and the interimplants in the cervical, middle, and apical regions when subjected to different loads with or without interposition of the flat occlusal plane splint. A photoelastic model was made with 2 external hexagon implants located in the space corresponding to the second premolar and molar inferiors. A screw-retained metal superstructure was installed on the implants with a torque of 20 N.cm, and the set (photoelastic model with superstructure) were positioned in the circular polariscope in the dark-field configuration to observe the distribution of isochromatic fringes around the implants and interimplant areas. Photographic records were obtained before the application of the occlusal load with the following loading conditions: 300, 600, and 900 N, with and without interposition of the occlusal plane splint. The decrease in stress with the application of the flat occlusal plane splint became more evident after the application of the 600-N load. Generally, the major stress magnitude occurred in the cervical region for interimplant areas and in the apical region around implants. Use of occlusal splint in the loading of 300, 600, and 900 N reduced tension 33.22%, 66.66%, and 73.33%, respectively, in the samples. It can be concluded that the interposition of the occlusal plane splint caused a reduction in tension resulting from the simulation of occlusal overload.
引用
收藏
页码:E477 / E480
页数:4
相关论文
共 28 条
  • [1] A 15-YEAR STUDY OF OSSEOINTEGRATED IMPLANTS IN THE TREATMENT OF THE EDENTULOUS JAW
    ADELL, R
    LEKHOLM, U
    ROCKLER, B
    BRANEMARK, PI
    [J]. INTERNATIONAL JOURNAL OF ORAL SURGERY, 1981, 10 (06): : 387 - 416
  • [2] A natural tooth's stress distribution in occlusion with a dental implant
    Akpinar, I
    Anil, N
    Parnas, L
    [J]. JOURNAL OF ORAL REHABILITATION, 2000, 27 (06) : 538 - 545
  • [3] American Society for Testing and Materials, 2001, STAND TEST METH PHOT, pD4093
  • [4] Analysis of load transfer and stress distribution by an implant-supported fixed partial denture
    Assif, D
    Marshak, B
    Horowitz, A
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1996, 75 (03) : 285 - 291
  • [5] Biomechanics Studies in Dentistry: Bioengineering Applied in Oral Implantology
    Assuncao, Wirley Goncalves
    Ricardo Barao, Valentim Adelino
    Tabala, Lucas Fernando
    Gomes, Erica Alves
    Delben, Juliana Aparecida
    dos Santos, Paulo Henrique
    [J]. JOURNAL OF CRANIOFACIAL SURGERY, 2009, 20 (04) : 1173 - 1177
  • [6] Sleep bruxism; an overview of an oromandibular sleep movement disorder
    Bader, G
    Lavigne, G
    [J]. SLEEP MEDICINE REVIEWS, 2000, 4 (01) : 27 - 43
  • [7] Branemark PI., 1969, Scand J Plast Rec Surg, V3, P81, DOI 10.3109/02844316909036699
  • [8] ROOT TIPPING - PHOTOELASTIC-HISTOPATHOLOGIC CORRELATION
    BRODSKY, JF
    CAPUTO, AA
    FURSTMAN, LL
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1975, 67 (01) : 1 - 10
  • [9] Canay S, 1996, Quintessence Int, V27, P591
  • [10] Implant design and interface force transfer - A photoelastic and strain-gauge analysis
    Cehreli, M
    Duyck, J
    De Cooman, M
    Puers, R
    Naert, I
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2004, 15 (02) : 249 - 257