New numerical simulation approach to calibrate the NaI(Tl) detectors array using non-axial extended spherical sources

被引:37
|
作者
Badawi, M. S. [1 ]
El-Khatib, A. M. [1 ]
Krar, M. E. [1 ]
机构
[1] Univ Alexandria, Fac Sci, Dept Phys, Alexandria 21511, Egypt
来源
JOURNAL OF INSTRUMENTATION | 2013年 / 8卷
关键词
Gamma detectors (scintillators; CZT; HPG; HgI etc); Detector modelling and simulations I (interaction of radiation with matter; interaction of photons with matter; interaction of hadrons with matter; etc); GAMMA-RAY SPECTROMETRY; ENERGY PEAK EFFICIENCY; SELF-ATTENUATION; HPGE DETECTORS; CALCULATE; CODES;
D O I
10.1088/1748-0221/8/11/P11005
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The aim of the current study was to utilize the efficiency transfer technique (ET) to obtain the full-energy peak efficiency (FEPE) applying a new numerical simulation approach. The approach was implemented on a detection system array composed of two [NaI (Tl)] detectors. The simulation approach included a derivative of the effective solid angles subtended by an arbitrarily located source and the active volume of the detectors. The attenuation of the source matrix, the source container and the end-caps of the detector materials were considered. Resulting outcomes have been compared with those measured by the NaI(Tl) detector array comprising different volumes as (3 '' x 3 '' & 2 '' x 2 '') and resolutions (FWHM) of 7.5% and 8.5% at 662 keV respectively. Eu-152 aqueous radioactive spherical sources were employed during the measurements, covering the energy range from 121.78 keV up to 1408.03 keV. A remarkable agreement was observed between the measured and the calculated efficiencies employing the new numerical approach. These conclusions were consistent for a variety of source-to-detector lateral distances, providing solid evidence for the stability of the developing method.
引用
收藏
页数:13
相关论文
共 16 条
  • [1] New analytical approach to calibrate the NaI (Tl) detectors using spherical radioactive sources
    El-Khatib, Ahmed M.
    Gouda, Mona M.
    Badawi, Mohamed S.
    Nafee, Sherif S.
    El-Mallah, Ekram A.
    RADIATION PROTECTION DOSIMETRY, 2013, 156 (01) : 109 - 117
  • [2] New numerical simulation method to calibrate the regular hexagonal NaI(Tl) detector with radioactive point sources situated non-axial
    Hamzawy, Ayman
    Grozdanov, Dimitar N.
    Badawi, Mohamed S.
    Aliyev, Fuad A.
    Thabet, Abouzeid A.
    Abbas, Mahmoud I.
    Ruskov, Ivan N.
    El-Khatib, Ahmed M.
    Kopatch, Yuri N.
    Gouda, Mona M.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (11):
  • [3] New numerical algorithm method to calibrate the HPGe cylindrical detectors using non-axial extended source geometries
    Nafee, Sherif S.
    Badawi, Mohamed S.
    Ahmed, Ayman H.
    APPLIED RADIATION AND ISOTOPES, 2010, 68 (09) : 1809 - 1815
  • [4] Efficiency of a cubic NaI(Tl) detector with rectangular cavity using standard radioactive point sources placed at non-axial position
    Abbas, Mahmoud, I
    Badawi, Mohamed S.
    Thabet, Abouzeid A.
    Kopatch, Yu N.
    Ruskov, Ivan N.
    Grozdanov, D. N.
    Noureddine, Salam
    Fedorov, N. A.
    Gouda, Mona M.
    Hramco, C.
    Abd-Elzaher, Mohamed
    Hamzawy, A.
    Elsafi, Mohamed
    El-Khatib, Ahmed M.
    APPLIED RADIATION AND ISOTOPES, 2020, 163
  • [5] New numerical evaluation of parallelepiped NaI(Tl) detector geometrical and total efficiencies using extended sources
    Noureddeen, S. F.
    Abbas, M. I.
    RADIOPROTECTION, 2017, 52 (04) : 265 - 271
  • [6] NEW NUMERICAL ALGORITHM METHOD CONSIDERING THE SELF-ABSORPTION OF THE SPHERICAL RADIOACTIVE SOURCES MATRIX TO CALIBRATE A SYSTEM OF TWO NaI GAMMA DETECTORS
    Krar, Mohamed E.
    El-Khatib, Ahmed M.
    Badawi, Mohamed S.
    NUCLEAR TECHNOLOGY, 2014, 187 (02) : 208 - 219
  • [7] Analytical approach to calculate the efficiency of 4π NaI(Tl) gamma-ray detectors for extended sources
    Abbas, Mahmoud I.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 615 (01): : 48 - 52
  • [8] A HYBRID ANALYTICAL-NUMERICAL METHOD FOR EFFICIENCY CALCULATIONS OF SPHERICAL SCINTILLATION NaI(Tl) DETECTORS AND ARBITRARILY LOCATED POINT SOURCES
    Noureldine, Salam E.
    Badawi, Mohamed S.
    Abbas, Mahmoud I.
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2017, 32 (02): : 140 - 147
  • [9] Calculation of full-energy peak efficiency of NaI (Tl) detectors by new analytical approach for parallelepiped sources
    El-Khatib, Ahmed M.
    Badawi, Mohamed S.
    Gouda, Mona M.
    Jovanovic, Slobodan I.
    Dlabac, Aleksandar D.
    Mihaljevic, Nikola N.
    Nafee, Sherif S.
    El-Mallah, Ekram A.
    JOURNAL OF THEORETICAL AND APPLIED PHYSICS, 2013, 7 (01)
  • [10] Calibration of 4π NaI(Tl) detectors with coincidence summing correction using new numerical procedure and ANGLE4 software
    Badawi, Mohamed S.
    Jovanovic, Slobodan I.
    Thabet, Abouzeid A.
    El-Khatib, Ahmed M.
    Dlabac, Aleksandar D.
    Salem, Bohaysa A.
    Gouda, Mona M.
    Mihaljevic, Nikola N.
    Almugren, Kholud S.
    Abbas, Mahmoud I.
    AIP ADVANCES, 2017, 7 (03)