共 50 条
Bacterial analysis by laser desorption ionization mass spectrometry on amorphous silicon
被引:4
|作者:
Kim, Shin Hye
[1
,2
]
Kim, Jeongkwon
[2
]
Jo, Seung-Hyun
[3
,4
]
Kim, Jeong-Hoon
[3
]
Kim, Kyung Joong
[5
]
Yoon, Sohee
[1
]
机构:
[1] Korea Res Inst Stand & Sci, Ctr Nanobio Measurement, Daejeon 34113, South Korea
[2] Chungnam Natl Univ, Dept Chem, Daejeon 34134, South Korea
[3] Korea Res Inst Biosci & Biotechnol, Personalized Genom Med Res Ctr, Daejeon 34141, South Korea
[4] Univ Sci & Technol, Dept Funct Genom, Daejeon 34113, South Korea
[5] Korea Res Inst Stand & Sci, Ctr New Funct Mat, Daejeon 34113, South Korea
基金:
新加坡国家研究基金会;
关键词:
INDUCED THERMAL-DESORPTION;
IONIC-LIQUID MATRICES;
MALDI-TOF;
BACILLUS-SUBTILIS;
DESORPTION/IONIZATION;
REPRODUCIBILITY;
TIME;
IDENTIFICATION;
PHOSPHOLIPIDS;
SUBLIMATION;
D O I:
10.1116/1.4972416
中图分类号:
Q6 [生物物理学];
学科分类号:
071011 ;
摘要:
Lipid profiling in nine bacterial species has been accomplished by laser desorption ionization mass spectrometry (LDI-MS) using amorphous silicon (a-Si) thin film with 100 nm thickness. Lipid ions could be generated by LDI on a-Si regardless of ion acquisition modes because of a thermal property of a-Si to govern laser-induced surface heating. In a comparative study of lipid profiling in Bacillus lichemiformis by LDI-MS and matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS), LDI-MS on a-Si shows a higher efficiency in lipid and lipopeptide detection than MALDI-MS. A total of 53 peaks of lipid ions generated by LDI on a-Si in both acquisition modes for m/z 400-1200 was 1.6 times more than that detected by MALDI-MS using three organic matrices-2,5-dihydroxybenzoic acid, 1,5-diaminonaphthalene, and 2,4,6-trihydroxyacetophenone monohydrate. Also, the authors demonstrate by mass spectrometry imaging (MSI) that LDI-MS provides high detection coverage through whole sample area. MSI results show the detection yield in LDI on a-Si is 94.8% calculated by counting the number of points detected in the analyte ion signal in a whole spot. It means that reproducible detection of lipid ions by LDI-MS is possible even if laser is randomly irradiated at any position within the bacterial sample area applied on a-Si. Lipid profiling by LDI-MS on a-Si was applied to bacterial differentiation of nine bacterial species conducted by performing principal component analysis. Nine bacterial species are successfully distinguishable from each other by LDI-MS lipid profiling. (C) 2016 American Vacuum Society.
引用
收藏
页数:9
相关论文