Patient Radiation Dose Reduction during Transarterial Chemoembolization Using a Novel X-Ray Imaging Platform

被引:5
作者
Kohlbrenner, Ryan [1 ]
Kolli, Pallav [1 ]
Taylor, Andrew G. [1 ]
Kohi, Maureen P. [1 ]
Fidelman, Nicholas [1 ]
LaBerge, Jeanne M. [1 ]
Kerlan, Robert K. [1 ]
Agarwal, Vishal K. [1 ]
Lehrman, Evan D. [1 ]
Nanavati, Sujal [1 ]
Avrin, David E. [1 ]
Gould, Robert [1 ]
机构
[1] Univ Calif San Francisco, Dept Radiol, San Francisco, CA 94143 USA
关键词
INTERVENTIONAL RADIOLOGY PROCEDURES; DIGITAL-SUBTRACTION-ANGIOGRAPHY; AREA PRODUCT; FLUOROSCOPY; TECHNOLOGY; QUALITY; TIME; IR;
D O I
10.1016/j.jvir.2015.06.016
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate radiation dose reduction in patients undergoing transarterial chemoembolization with the use of a new image acquisition and processing platform. Materials and 'Methods: Radiation-dose data were obtained from 176 consecutive chemoembolization procedures in 135 patients performed in a single angiography suite. From January 2013 through October 2013, 85 procedures were, performed by using our institution's standard fluoroscopic settings. After upgrading the x-ray fluoroscopy system with an image acquisition and processing platform designed to reduce image noise and reduce skin entrance dose, 91 chemoembolization procedures were performed from November 2013 through December 2014. Cumulative dose area product (CDAP), cumulative air kerma (CAK), and total fluoroscopy time were recorded for each procedure. Image quality was assessed by three interventional radiologists blinded to the x-ray acquisition platform used. Results: Patient radiation dose indicators were significantly lower for chemoembolization procedures perfauned with the novel imaging platform. Mean CDAP decreased from 3,033.2 dGy.cm(2) (range, 600.3-9,404.1 dGy.cm(2)) to 1,640.1 dGy.cm(2) (range, 278.6-6,779.9 dGy.cm(2); 45.9% reduction; P<.00001). Mean CAK 'decreased from 1,445.4 mGy (range, 303.6-5,233.7 mGy) to 971.7 mGy (range, 144.2-3,512.0 mGy; 32.8% reduction; P<.0001). A 20.3% increase in mean total fluoroscopy time was noted after upgrading the imaging platform, but blinded analysis of the image quality revealed no significant degradation. Conclusions: Although a small increase in fluoroscopy time was observed, a significant reduction in patient radiation dose was achieved by using the optimized imaging platform, without image quality degradation.
引用
收藏
页码:1331 / 1338
页数:8
相关论文
共 50 条
[41]   A Multimodality Image Guided Precision Radiation Research Platform: Integrating X-ray, Bioluminescence, and Fluorescence Tomography With Radiation Therapy [J].
Shi, Junwei ;
Xu, Keying ;
Keyvanloo, Amir ;
Udayakumar, Thirupandiyur S. ;
Ahmad, Anis ;
Yang, Fei ;
Yang, Yidong .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (04) :1063-1072
[42]   X-ray dose reduction by adaptive source equalization and electronic region-of-interest control [J].
Burion, Steve ;
Sandman, Anne ;
Bechtel, Kate ;
Solomon, Edward ;
Funk, Tobias .
MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
[43]   Reducing Pediatric Intraoral Radiography Radiation Dose Using Reduced-Power Dental X-Ray Units: A Randomized Trial [J].
Cully, Jennifer L. ;
Somasundaram, Elanchezhian ;
Campbell, Richard ;
Brady, Samuel L. ;
Gosnell, Elizabeth S. ;
Specht, Sarah ;
Candon, Lisa Atlas ;
Strauss, Keith J. .
JOURNAL OF DENTISTRY FOR CHILDREN, 2022, 89 (02) :95-103
[44]   Intraoral Radiology in General Dental Practices - A Comparison of Digital and Film-Based X-Ray Systems with Regard to Radiation Protection and Dose Reduction [J].
Anissi, H. D. ;
Geibel, M. A. .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2014, 186 (08) :762-767
[45]   The Effect of Low Frame Rate Fluoroscopy on the X-ray Dose during Coronary Intervention [J].
Sadamatsu, Kenji ;
Nakano, Yasuhiro .
INTERNAL MEDICINE, 2016, 55 (15) :1943-1946
[46]   Radiation Dose Reduction in Body Interventional Radiology: Clinical Results Utilizing a New Imaging Acquisition and Processing Platform [J].
Kohlbrenner, R. ;
Kolli, K. P. ;
Taylor, A. ;
Kohi, M. ;
Fidelman, N. ;
LaBerge, J. ;
Kerlan, R. ;
Gould, R. .
MEDICAL PHYSICS, 2014, 41 (06) :103-+
[47]   Radiation Dose Reduction in CT Myocardial Perfusion Imaging Using SMART-RECON [J].
Li, Yinsheng ;
Speidel, Michael A. ;
Francois, Christopher J. ;
Chen, Guang-Hong .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2017, 36 (12) :2557-2568
[48]   Reducing radiation dose by application of optimized low-energy x-ray filters to K-edge imaging with a photon counting detector [J].
Choi, Yu-Na ;
Lee, Seungwan ;
Kim, Hee-Joung .
PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (02) :N35-N49
[49]   Systematic literature review on the benefit of patient protection shielding during medical X-ray imaging: Towards a discontinuation of the current practice [J].
Samara, Eleni Theano ;
Saltybaeva, Natalia ;
Merce, Marta Sans ;
Gianolini, Stefano ;
Ith, Michael .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 94 :102-109
[50]   Evaluation of a new very low dose imaging protocol: feasibility and impact on X-ray dose levels in electrophysiology procedures [J].
Bourier, Felix ;
Reents, Tilko ;
Ammar-Busch, Sonia ;
Buiatti, Alessandra ;
Kottmaier, Marc ;
Semmler, Verena ;
Telishevska, Marta ;
Brkic, Amir ;
Grebmer, Christian ;
Lennerz, Carsten ;
Kolb, Christof ;
Hessling, Gabriele ;
Deisenhofer, Isabel .
EUROPACE, 2016, 18 (09) :1406-1410