Patient Radiation Dose Reduction during Transarterial Chemoembolization Using a Novel X-Ray Imaging Platform

被引:5
作者
Kohlbrenner, Ryan [1 ]
Kolli, Pallav [1 ]
Taylor, Andrew G. [1 ]
Kohi, Maureen P. [1 ]
Fidelman, Nicholas [1 ]
LaBerge, Jeanne M. [1 ]
Kerlan, Robert K. [1 ]
Agarwal, Vishal K. [1 ]
Lehrman, Evan D. [1 ]
Nanavati, Sujal [1 ]
Avrin, David E. [1 ]
Gould, Robert [1 ]
机构
[1] Univ Calif San Francisco, Dept Radiol, San Francisco, CA 94143 USA
关键词
INTERVENTIONAL RADIOLOGY PROCEDURES; DIGITAL-SUBTRACTION-ANGIOGRAPHY; AREA PRODUCT; FLUOROSCOPY; TECHNOLOGY; QUALITY; TIME; IR;
D O I
10.1016/j.jvir.2015.06.016
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate radiation dose reduction in patients undergoing transarterial chemoembolization with the use of a new image acquisition and processing platform. Materials and 'Methods: Radiation-dose data were obtained from 176 consecutive chemoembolization procedures in 135 patients performed in a single angiography suite. From January 2013 through October 2013, 85 procedures were, performed by using our institution's standard fluoroscopic settings. After upgrading the x-ray fluoroscopy system with an image acquisition and processing platform designed to reduce image noise and reduce skin entrance dose, 91 chemoembolization procedures were performed from November 2013 through December 2014. Cumulative dose area product (CDAP), cumulative air kerma (CAK), and total fluoroscopy time were recorded for each procedure. Image quality was assessed by three interventional radiologists blinded to the x-ray acquisition platform used. Results: Patient radiation dose indicators were significantly lower for chemoembolization procedures perfauned with the novel imaging platform. Mean CDAP decreased from 3,033.2 dGy.cm(2) (range, 600.3-9,404.1 dGy.cm(2)) to 1,640.1 dGy.cm(2) (range, 278.6-6,779.9 dGy.cm(2); 45.9% reduction; P<.00001). Mean CAK 'decreased from 1,445.4 mGy (range, 303.6-5,233.7 mGy) to 971.7 mGy (range, 144.2-3,512.0 mGy; 32.8% reduction; P<.0001). A 20.3% increase in mean total fluoroscopy time was noted after upgrading the imaging platform, but blinded analysis of the image quality revealed no significant degradation. Conclusions: Although a small increase in fluoroscopy time was observed, a significant reduction in patient radiation dose was achieved by using the optimized imaging platform, without image quality degradation.
引用
收藏
页码:1331 / 1338
页数:8
相关论文
共 50 条
[31]   Radiation dose to staff from medical X-ray scatter in the orthopaedic theatre [J].
T. Dorman ;
B. Drever ;
S. Plumridge ;
K. Gregory ;
M. Cooper ;
A. Roderick ;
E. Arruzza .
European Journal of Orthopaedic Surgery & Traumatology, 2023, 33 :3059-3065
[32]   REDUCTION OF RADIATION EXPOSURE WHILE MAINTAINING HIGH-QUALITY FLUOROSCOPIC IMAGES DURING INTERVENTIONAL CARDIOLOGY USING NOVEL X-RAY TUBE TECHNOLOGY WITH EXTRA BEAM FILTERING [J].
DENBOER, A ;
DEFEYTER, PJ ;
HUMMEL, WA ;
KEANE, D ;
ROELANDT, JRTC .
CIRCULATION, 1994, 89 (06) :2710-2714
[33]   Modified Chest X-Ray Radiography through Glass Window for Imaging COVID-19 Pneumonia: Techniques and Radiation Dose [J].
Suliman, Ibrahim I. ;
Khouqeer, Ghada A. ;
Ahmed, Nada A. ;
Abuzaid, Mohamed M. ;
Sulieman, Abdelmoneim .
INTERNATIONAL JOURNAL OF BIOMEDICINE, 2023, 13 (02) :194-201
[34]   X-ray source arrays for volumetric imaging during radiotherapy treatment [J].
Dillon, Owen ;
Reynolds, Tess ;
O'Brien, Ricky T. .
SCIENTIFIC REPORTS, 2023, 13 (01)
[35]   Clinical apparatus for the reduction of dose area product for patients undergoing x-ray catheterization [J].
Robert, Normand ;
Watt, Kristina N. ;
Rochette, Sophie ;
Desponds, Lionel ;
Vaillant, Regis ;
Rowlands, John A. .
MEDICAL PHYSICS, 2015, 42 (01) :521-530
[36]   Radiation dose reduction in cerebral CT perfusion imaging using iterative reconstruction [J].
Niesten, Joris M. ;
van der Schaaf, Irene C. ;
Riordan, Alan J. ;
de Jong, Hugo W. A. M. ;
Horsch, Alexander D. ;
Eijspaart, Daniel ;
Smit, Ewoud J. ;
Mali, Willem P. T. M. ;
Velthuis, Birgitta K. .
EUROPEAN RADIOLOGY, 2014, 24 (02) :484-493
[37]   Patient and physician radiation exposure during minimally invasive lumbar decompression: A prospective assessment of X-ray exposure risks [J].
Mekhail, Nagy ;
Topalsky, Krista ;
Templeton, Erin ;
Armanyous, Sherif ;
Prayson, Nicholas ;
Olde, Carl ;
Costandi, Shrif .
PAIN PRACTICE, 2024, 24 (04) :600-608
[38]   Radiation dose measurements of an on-board imager X-ray unit using optically-stimulated luminescence dosimeters [J].
Smith, Leon ;
Haque, Mamoon ;
Morales, Johnny ;
Hill, Robin .
AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2015, 38 (04) :665-669
[39]   A novel nanochannel fabrication for nanofluidic applications using synchrotron radiation via a micro patterned X-ray mask [J].
Jeon, Hyungkook ;
Kim, Jong Hyun ;
Lim, Geunbae .
RSC ADVANCES, 2016, 6 (52) :46068-46072
[40]   Radiation exposure after cardiac X-ray imaging: risk and prevention in daily practise [J].
Pernes, Jean-Marc ;
Dupouy, Patrick ;
Aptecar, Eduardo ;
Auguste, Mario ;
Hakim, Dia ;
Fareed, Ahmed ;
Huart, Valerie ;
Schoukroun, Gregory ;
Labbe, Ramon ;
Haquin, Gerard ;
Gaux, Jean-Claude .
SANG THROMBOSE VAISSEAUX, 2010, 22 (10) :523-535