Repeatability of Regional Lung Ventilation Quantification Using Fluorinated (19F) Gas Magnetic Resonance Imaging

被引:15
|
作者
Gutberlet, Marcel [1 ,2 ,3 ]
Kaireit, Till F. [1 ,2 ,3 ]
Voskrebenzev, Andreas [1 ,2 ,3 ]
Kern, Agilo L. [1 ,2 ,3 ]
Obert, Arnd [1 ,2 ,3 ]
Wacker, Frank [1 ,2 ,3 ]
Hohlfeld, Jens M. [2 ,3 ,4 ,5 ]
Vogel-Claussen, Jens [1 ,2 ,3 ]
机构
[1] Hannover Med Sch, Inst Diagnost & Intervent Radiol, Carl Neuberg Str 1, D-30625 Hannover, Germany
[2] Biomed Res Endstage & Obstruct Lung Dis Hannover, Hannover, Germany
[3] German Ctr Lung Res, Hannover, Germany
[4] Hannover Med Sch, Clin Pneumol, Hannover, Germany
[5] Clin Airway Res, Fraunhofer Inst Toxicol & Expt Med, Hannover, Germany
关键词
Pulmonary; F-19; Fluorine; Lung; Magnetic resonance; Gas washout; COPD; HYPERPOLARIZED HE-3 MRI; DIFFUSION; OXYGEN; MIXTURES; HEALTHY; COPD; T-1;
D O I
10.1016/j.acra.2018.10.021
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: To assess the repeatability of global and regional lung ventilation quantification in both healthy subjects and patients with chronic obstructive pulmonary disease (COPD) using fluorinated (F-19) gas washout magnetic resonance (MR) imaging in free breathing. Material and Methods: In this prospective institutional review board-approved. study, 12 healthy non-smokers and eight COPD patients were examined with F-19 dynamic gas washout MR imaging in free breathing and with lung function testing. Measurements were repeated within 2 weeks. Lung ventilation was quantified using( 19)F gas washout time. Repeatability was analyzed for the total lung and on a regional basis using the coefficient of variation (COV) and Bland-Altman plots. Results: In healthy subjects and COPD patients, a good repeatability was found for lung ventilation quantification using dynamic F-19 gas washout MR imaging on a global (COV < 8%) and regional (COV < 15%) level. Gas washout time was significantly increased in the COPD group compared to the healthy subjects. Conclusion: F-19 gas washout MR imaging provides a good repeatability of lung ventilation quantification and appears to be sensitive to early changes of regional lung function alterations such as normal aging.
引用
收藏
页码:395 / 403
页数:9
相关论文
共 50 条
  • [1] Volume-Controlled 19F MR Ventilation Imaging of Fluorinated Gas
    Obert, Arnd J.
    Kern, Agilo L.
    Gutberlet, Marcel
    Voskrebenzev, Andreas
    Kaireit, Till F.
    Crisosto, Cristian
    Greer, Mark
    Krause, E. Tobias
    Wacker, Frank
    Vogel-Claussen, Jens
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2023, 57 (04) : 1114 - 1128
  • [2] Breathhold 19F-magnetic resonance imaging of lung ventilation using SF6 gas.
    Schreiber, WG
    Markstaller, K
    Weiler, N
    Eberle, B
    Laukemper-Ostendorf, S
    Scholz, A
    Bürger, K
    Thelen, M
    Kauczor, HU
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2000, 172 (06): : 500 - 503
  • [3] Pulmonary Ultrashort Echo Time 19F MR Imaging with Inhaled Fluorinated Gas Mixtures in Healthy Volunteers: Feasibility
    Couch, Marcus J.
    Ball, Iain K.
    Li, Tao
    Fox, Matthew S.
    Littlefield, Shalyn L.
    Biman, Birubi
    Albert, Mitchell S.
    RADIOLOGY, 2013, 269 (03) : 903 - 909
  • [4] 19F MR imaging of ventilation and diffusion in excised lungs
    Jacob, RE
    Chang, YV
    Choong, CK
    Bierhals, A
    Hu, DZ
    Zheng, J
    Yablonskiy, DA
    Woods, JC
    Gierada, DS
    Conradi, MS
    MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (03) : 577 - 585
  • [5] 19F MRI of the Lungs Using Inert Fluorinated Gases: Challenges and New Developments
    Couch, Marcus J.
    Ball, Iain K.
    Li, Tao
    Fox, Matthew S.
    Biman, Birubi
    Albert, Mitchell S.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2019, 49 (02) : 343 - 354
  • [6] Calcium Fluoride Nanocrystals: Tracers for In Vivo 19F Magnetic Resonance Imaging
    Ashur, Idan
    Allouche-Arnon, Hyla
    Bar-Shir, Amnon
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2018, 57 (25) : 7478 - 7482
  • [7] Dual Nanoparticle Conjugates for Highly Sensitive and Versatile Sensing Using 19F Magnetic Resonance Imaging
    Cooke, Daniel J.
    Maier, Esther Y.
    King, Tyler L.
    Lin, Haoding
    Hendrichs, Santiago
    Lee, Slade
    Mafy, Noushaba N.
    Scott, Kathleen M.
    Lu, Yi
    Que, Emily L.
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2024, 63 (04)
  • [8] Examining lung microstructure using 19F MR diffusion imaging in COPD patients
    Obert, Arnd Jonathan
    Gutberlet, Marcel
    Kern, Agilo Luitger
    Kaireit, Till Frederik
    Glandorf, Julian
    Alsady, Tawfik Moher
    Wacker, Frank
    Hohlfeld, Jens Michael
    Vogel-Claussen, Jens
    MAGNETIC RESONANCE IN MEDICINE, 2022, 88 (02) : 860 - 870
  • [9] Monitoring Dendritic Cell Migration using 19F / 1H Magnetic Resonance Imaging
    Waiczies, Helmar
    Guenther, Martin
    Skodowski, Julia
    Lepore, Stefano
    Pohlmann, Andreas
    Niendorf, Thoralf
    Waiczies, Sonia
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2013, (73):
  • [10] Regional ventilation mapping of the rat lung using hyperpolarized 129Xe magnetic resonance imaging
    Couch, Marcus J.
    Ouriadov, Alexei
    Santyr, Giles E.
    MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (05) : 1623 - 1631