High-resolution three-dimensional active imaging with uniform distance resolution

被引:8
|
作者
Zhang, Xiuda [1 ]
Wu, Yulin [1 ]
Chen, Huifang [2 ]
Yan, Huimin [1 ]
机构
[1] Zhejiang Univ, Dept Opt Engn, Natl Engn Res Ctr Opt Instrument, Natl State Key Lab Opt Instrument, Hangzhou 310027, Zhejiang, Peoples R China
[2] China Jiliang Univ, Coll Opt & Elect Technol, Hangzhou 310018, Zhejiang, Peoples R China
关键词
Three-dimensional; Active imaging; Pulsed laser; Uniform distance resolution distribution; LASER-RADAR; RANGE; SYSTEMS;
D O I
10.1016/j.optcom.2013.08.071
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We present a method to ensure uniform distance resolution distribution of three-dimensional (3D) active imaging and to improve distance resolution. Rising and falling edges were employed to encode the object depth, which has a uniform distance resolution distribution when the laser pulse shape is Gaussian. The 3D method uses a pulsed laser as the flood illuminating source and an intensified camera as the receiver. A scene at a 50 m distance was detected at a resolution of about 0.1 m, which is about three times better than that obtained by using the conventional method. (c) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:47 / 51
页数:5
相关论文
共 50 条
  • [31] Using carbon nanotube probes for high-resolution three-dimensional imaging of cells
    Koehne, J. E.
    Stevens, R. M.
    Zink, T.
    Deng, Z.
    Chen, H.
    Weng, I. C.
    Liu, F. T.
    Liu, G. Y.
    ULTRAMICROSCOPY, 2011, 111 (08) : 1155 - 1162
  • [32] Segmental analysis of cochlea on three-dimensional MR imaging and high-resolution CT
    Akiba, H
    Tamakawa, M
    Hyodoh, H
    Hyodoh, K
    Nakamura, N
    Yama, N
    RADIOLOGY, 2001, 221 : 135 - 135
  • [33] High-resolution three-dimensional imaging by synchrotron-radiation computed laminography
    Helfen, L.
    Baumbach, T.
    Pernot, P.
    Mikulik, P.
    DiMichiel, M.
    Baruchel, J.
    DEVELOPMENTS IN X-RAY TOMOGRAPHY V, 2006, 6318
  • [34] LONGITUDINAL MONITORING OF ANGIOGENESIS USING HIGH-RESOLUTION THREE-DIMENSIONAL ULTRASOUND IMAGING
    Mukai, K.
    Zhu, W.
    Nakajima, Y.
    Kobayashi, M.
    Nakatani, T.
    WOUND REPAIR AND REGENERATION, 2018, 26 (02) : A5 - A5
  • [35] High-resolution digital holographic microtomography for three-dimensional refractive index imaging
    Ma, Li-Hong
    Su, Ling-Long
    Wang, Hui
    Jin, Hong-Zhen
    Guangzi Xuebao/Acta Photonica Sinica, 2014, 43 (10):
  • [36] High-resolution three-dimensional probes of biomaterials and their interfaces
    Grandfield, Kathryn
    Palmquist, Anders
    Engqvist, Hakan
    PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 2012, 370 (1963): : 1337 - 1351
  • [37] High-resolution three-dimensional simulations of relativistic jets
    Aloy, MA
    Ibáñez, JM
    Martí, JM
    Gómez, JL
    Müller, E
    ASTROPHYSICAL JOURNAL, 1999, 523 (02): : L125 - L128
  • [38] Autofocusing method for high-resolution three-dimensional profilometry
    Hu, Xiaowei
    Wang, Guijin
    Hyun, Jae-Sang
    Zhang, Yujin
    Yang, Huazhong
    Zhang, Song
    Optics Letters, 2020, 45 (02): : 375 - 378
  • [39] Autofocusing method for high-resolution three-dimensional profilometry
    Hu, Xiaowei
    Wang, Guijin
    Hyun, Jae-Sang
    Zhang, Yujin
    Yang, Huazhong
    Zhang, Song
    OPTICS LETTERS, 2020, 45 (02) : 375 - 378
  • [40] High resolution three-dimensional prostate ultrasound imaging
    Li, Yinbo
    Patil, Abhay
    Hossack, John A.
    MEDICAL IMAGING 2006: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2006, 6147