Resonance frequency measurements of implant stability in vivo - A cross-sectional and longitudinal study of resonance frequency measurements on implants in the edentulous and partially dentate maxilla

被引:348
|
作者
Meredith, N
Book, K
Friberg, B
Jemt, T
Sennerby, L
机构
[1] Dept. of Oral and Dental Science, University of Bristol Dental School, Bristol BS1 2LY, Lower Maudlin Street
[2] Dept. of Biomaterials/Handicap Res., Institute for Surgical Sciences, Göteborg University, Gothenburg
[3] Branemark Clinic, Public Dental Health, University of Göteborg, Gothenburg
关键词
dental; implant; osseointegration; resonance frequency; stability;
D O I
10.1034/j.1600-0501.1997.080309.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aim of this investigation was to evaluate the use of resonance frequency measurements in the clinical measurement of implant stability. Resonance frequency measurements are undertaken by measuring the response of a small transducer attached to an implant fixture or abutment. Two groups of patients were selected for study. Group A comprised 9 patients who had a total of 56 implants placed. Resonance frequency measurements were made at fixture installation and repeated 8 months later at abutment connection. The resonance frequency of the implant/transducer system increased for 50 out of the 56 implants from a mean value of 7473 Hz +/- 127 Hz (P<0.05) to a mean of 7915 Hz +/- 112 Hz (P<0.05). Two implants had failed to integrate and the resonance frequency of these had fallen. Group B comprised 9 patients who had been provided with fixed prostheses and had a total of 52 implants placed. They were examined 5 years after fixture placement and the prostheses removed. All implants were judged clinically to be osseointegrated. The level of the marginal bone around each implant was calculated by measuring the number of exposed threads on intraoral periapical radiographs and added to the length of each abutment to give a value termed the effective implant length (EIL). Measurements indicated a correlation (R = -0.78, P<0.01) between EIL and resonance frequency. The results support the hypothesis that the resonance frequency of an implant/ transducer system is related to the height of the implant not surrounded by bone and the stability of the implant/tissue interface as determined by the absence of clinical mobility.
引用
收藏
页码:226 / 233
页数:8
相关论文
共 38 条
  • [21] - IMPLANT STABILITY COMPARISON OF IMMEDIATE AND DELAYED MAXILLARY IMPLANT PLACEMENT BY USE OF RESONANCE FREQUENCY ANALYSIS - A CLINICAL STUDY
    Granic, Marko
    Katanec, Davor
    Boras, Vanja Vucicevic
    Susic, Mato
    Juric, Ivona Bago
    Gabric, Dragana
    ACTA CLINICA CROATICA, 2015, 54 (01) : 3 - 8
  • [22] Efficiency Of Customized Connectors In Evaluatingmini Implant Stability Using Resonance Frequency Analysis - An In Vitro Study
    Padmavati
    Keerthana, S. Vaibava
    Saravanan, B.
    INTERNATIONAL JOURNAL OF LIFE SCIENCE AND PHARMA RESEARCH, 2021, : 133 - 138
  • [23] Comparison of Measurements of Implant Stability by Two Different Radio Frequency Analysis Systems: An In Vitro Study
    Koyuncuoglu, Cenker Zeki
    Demir, Becen
    JOURNAL OF ADVANCED ORAL RESEARCH, 2020, 11 (02) : 202 - 207
  • [24] Resonance frequency measurements in vivo and related surface properties of magnesium-incorporated, micropatterned and magnesium-incorporated TiUnite®, Osseotite®, SLA® and TiOblast® implants
    Sul, Young-Taeg
    Jonsson, Jorgen
    Yoon, Goui-Seong
    Johansson, Carina
    CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 (10) : 1146 - 1155
  • [25] Implant Primary Stability Determined by Resonance Frequency Analysis in Surgically Created Defects: A Pilot Cadaver Study
    Chan, Hsun-Liang
    El-Kholy, Karim
    Fu, Jia-Hui
    Galindo-Moreno, Pablo
    Wang, Hom-Lay
    IMPLANT DENTISTRY, 2010, 19 (06) : 509 - 519
  • [26] Two Alternative Surgical Techniques for Enhancing Primary Implant Stability in the Posterior Maxilla: A Clinical Study Including Bone Density, Insertion Torque, and Resonance Frequency Analysis Data
    Turkyilmaz, Ilser
    Aksoy, Utku
    McGlumphy, Edwin A.
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2008, 10 (04) : 231 - 237
  • [27] Effects of continual intermittent administration of parathyroid hormone on implant stability in the presence of osteoporosis: an in vivo study using resonance frequency analysis in a rabbit model
    Oki, Yoshifumi
    Doi, Kazuya
    Makihara, Yusuke
    Kobatake, Reiko
    Kubo, Takayasu
    Tsuga, Kazuhiro
    JOURNAL OF APPLIED ORAL SCIENCE, 2017, 25 (05) : 498 - 505
  • [28] The influence of fixation in formalin on the measurement of stability of implants using resonance frequency analysis and Periotest M®: A study in a dog
    Doi, Kazuya
    Kajihara, Shiho
    Morita, Koji
    Makihara, Yusuke
    Okada, Shinsuke
    Akagawa, Yasumasa
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2014, 52 (01) : 29 - 33
  • [29] The Possible Association Among Bone Density Values, Resonance Frequency Measurements, Tactile Sense, and Histomorphometric Evaluations of Dental Implant Osteotomy Sites: A Preliminary Study
    Aksoy, Utku
    Eratalay, Kenan
    Tozum, Tolga F.
    IMPLANT DENTISTRY, 2009, 18 (04) : 316 - 325
  • [30] Influence of implant dimensions and position on primary and secondary stability: a prospective clinical study in the mandible using resonance frequency analysis
    Rengo, C.
    Nappo, A.
    Pantaleo, G.
    Spagnuolo, G.
    Ferrari, M.
    JOURNAL OF OSSEOINTEGRATION, 2020, 12 (01) : 34 - 38