Biomechanical Comparison of Modified Kessler and Running Suture Repair in 3 Different Animal Tendons and in Human Flexor Tendons

被引:40
作者
Hausmann, Jan-Till
Vekszler, Gyoergy
Bijak, Manfred
Benesch, Thomas
Vecsei, Vilmos
Gaebler, Christian
机构
[1] Univ Med, Dept Traumatol, Vienna, Austria
[2] Univ Med, Dept Biomed Engn & Phys, Vienna, Austria
[3] Core Unit Med Stat & Informat, Sect Med Stat, Vienna, Austria
来源
JOURNAL OF HAND SURGERY-AMERICAN VOLUME | 2009年 / 34A卷 / 01期
关键词
Biomechanical setup; cyclic loading; flexor tendon; gap formation; Kessler; GAP FORMATION; CORE SUTURE; TENSILE-STRENGTH; CADAVER MODEL; PURCHASE; EXCURSION; DOGS;
D O I
10.1016/j.jhsa.2008.09.015
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose To establish the animal flexor tendon that best mimics the biomechanical performance of human flexor tendons. We investigated the biomechanical behavior of core and running sutures in 3 different animal flexor tendons and in human flexor tendons. Additionally, we attempted to help standardize future flexor tendon studies. To that purpose, nearly all variables occurring in the test setup have been highlighted. Methods The species selected were pig, calf, sheep, and human. Two groups were formed. In the first group we tested 3-0 core sutures (Ticron; Tyco Healthcare, Vienna, Austria), and in the second group we tested 5-0 running sutures (Ethilon; Ethicon, Vienna, Austria). In each group, 10 tendons of each specimen were tested, which yielded a total of 80 tendons. In each group, the repaired tendons were subjected to 3,000 linear load cycles at a load of 15 N. At the end of this procedure, final gap values were recorded. In the next step, ultimate load-to-failure data were obtained from each specimen. Results Core sutures behaved similarly in the human, sheep, and pig tendons with respect to ultimate loads. With respect to gap formation, core sutures behaved similarly in the human, sheep, and calf tendons. Deep running sutures behaved similarly in the human, sheep, and pig tendons in terms of ultimate load to failure. Conclusions In this study, sheep tendons were found to best mimic the biomechanical behavior of human tendons. Calf tendons seem to be unsuitable. There is a strong need for consistency in biomechanical test setups. (J Hand Surg 2009;34A:93-.101. (C) 2009 Published by Elsevier Inc. on behalf of the American Society for Surgery of the Hand.)
引用
收藏
页码:93 / 101
页数:9
相关论文
共 40 条
[1]   ANATOMY OF HEREDITARY BOVINE SYNDACTYLISM .2. MUSCLES, TENDONS, AND LIGAMENTS [J].
ADRIAN, RW ;
LEIPOLD, HW ;
HUSTON, K ;
TROTTER, DM ;
DENNIS, SM .
JOURNAL OF DAIRY SCIENCE, 1969, 52 (09) :1432-&
[2]   A biomechanical comparison of multistrand flexor tendon repairs using an in situ testing model [J].
Barrie, KA ;
Wolfe, SW ;
Shean, C ;
Shenbagamurthi, D ;
Slade, FF ;
Panjabi, MM .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2000, 25A (03) :499-506
[3]   The role of multiple strands and locking sutures on cap formation of flexor tendon repairs during cyclical loading [J].
Barrie, KA ;
Tomak, SL ;
Cholewicki, L ;
Wolfe, SW .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2000, 25A (04) :714-720
[4]   Good preservation of initial mechanical properties in lipid-extracted, disinfected, freeze-dried sheep patellar tendon grafts [J].
Bettin, D ;
Polster, J ;
Rullkötter, V ;
von Versen, R ;
Fuchs, S .
ACTA ORTHOPAEDICA SCANDINAVICA, 2003, 74 (04) :470-475
[5]   Influence of core suture purchase length on strength of four-strand tendon repairs [J].
Cao, Y ;
Zhu, B ;
Xie, RG ;
Tang, JB .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2006, 31A (01) :107-112
[6]   Biomechanical evaluation of a four-strand modification of the Tang method of tendon repair [J].
Cao, Y ;
Tang, JB .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 2005, 30B (04) :374-378
[7]   Cyclical testing of zone II flexor tendon repairs [J].
Choueka, J ;
Heminger, H ;
Mass, DP .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2000, 25A (06) :1127-1134
[8]   Effect of peripheral suture depth on strength of tendon repairs [J].
Diao, E ;
Hariharan, JS ;
Soejima, O ;
Lotz, JC .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1996, 21A (02) :234-239
[9]   The resistance of a four- and eight-strand suture technique to gap formation during tensile testing:: An experimental study of repaired canine flexor tendons after 10 days of in vivo healing [J].
Dinopoulos, HT ;
Boyer, MI ;
Burns, ME ;
Gelberman, RH ;
Silva, MJ .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2000, 25A (03) :489-498
[10]   Optimizing biomechanical performance of the 4-strand cruciate flexor tendon repair [J].
Dona, E ;
Gianoutsos, MP ;
Walsh, WR .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2004, 29A (04) :571-580