Sensitive and Rapid UHPLC-MS/MS for the Analysis of Tomato Phenolics in Human Biological Samples

被引:15
|
作者
Martinez-Huelamo, Miriam [1 ,2 ]
Tulipani, Sara [3 ]
Jauregui, Olga [4 ]
Valderas-Martinez, Palmira [2 ,5 ]
Vallverdu-Queralt, Anna [2 ,6 ]
Estruch, Ramon [2 ,5 ]
Torrado, Xavier [1 ]
Lamuela-Raventos, Rosa M. [1 ,2 ]
机构
[1] Univ Barcelona, Dept Nutr & Food Sci XARTA INSA, Sch Pharm, E-08028 Barcelona, Spain
[2] Carlos III Hlth Inst, Ctr Biomed Network Res Pathophysiol Obes & Nutr C, Madrid 28029, Spain
[3] Univ Malaga, Hosp Virgen Victoria, Biomed Res Inst IBIMA, Serv Endocrinol & Nutr, Malaga 29010, Spain
[4] Univ Barcelona CCiTUB, Ctr Sci & Technol, Barcelona 08028, Spain
[5] Univ Barcelona, Dept Internal Med, Hosp Clin, Inst Biomed Invest August Pi I Sunyer IDIBAPS, E-08028 Barcelona, Spain
[6] INRA, Sci Oenol UMR1083, F-34060 Montpellier, France
关键词
polyphenol metabolites; validation; tomato; sauce; microbiota; metabolites; biosamples; blood; urine; PERFORMANCE LIQUID-CHROMATOGRAPHY; POLYPHENOL-RICH FOODS; MASS-SPECTROMETRY; CAPILLARY-ELECTROPHORESIS; BIOACTIVE COMPOUNDS; URINARY-EXCRETION; UPLC; METABOLITES; VALIDATION; ACIDS;
D O I
10.3390/molecules201119702
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
An UHPLC-MS/MS method for the quantification of tomato phenolic metabolites in human fluids was optimized and validated, and then applied in a pilot dietary intervention study with healthy volunteers. A 5-fold gain in speed (3.5 min of total run); 7-fold increase in MS sensitivity and 2-fold greater efficiency (50% peak width reduction) were observed when comparing the proposed method with the reference-quality HPLC-MS/MS system, whose assay performance has been previously documented. The UHPLC-MS/MS method led to an overall improvement in the limits of detection (LOD) and quantification (LOQ) for all the phenolic compounds studied. The recoveries ranged between 68% and 100% in urine and 61% and 100% in plasma. The accuracy; intra- and interday precision; and stability met with the acceptance criteria of the AOAC International norms. Due to the improvements in the analytical method; the total phenolic metabolites detected in plasma and urine in the pilot intervention study were 3 times higher than those detected by HPLC-MS/MS. Comparing with traditional methods; which require longer time of analysis; the methodology described is suitable for the analysis of phenolic compounds in a large number of plasma and urine samples in a reduced time frame.
引用
收藏
页码:20409 / 20425
页数:17
相关论文
共 50 条
  • [41] A highly sensitive UHPLC-MS/MS method for urine biological monitoring of occupational exposure to anthracycline antineoplastic drugs and routine application
    Villa, Antoine
    Tremolet, Kevin
    Martinez, Beatrice
    Cacao, Oscar Da Silva
    Atge, Benoit
    Ducint, Dominique
    Titier-Debeaupuis, Karine
    Verdun-Esquer, Catherine
    Molimard, Mathieu
    Canal-Raffin, Mireille
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2020, 1156 (1156):
  • [42] Development and validation of a UHPLC-MS/MS method for the identification of irinotecan photodegradation products in water samples
    Gosetti, Fabio
    Belay, Masho Hilawie
    Marengo, Emilio
    Robotti, Elisa
    ENVIRONMENTAL POLLUTION, 2020, 256 (256)
  • [43] HILIC UHPLC-MS/MS for fast and sensitive bioanalysis: accounting for matrix effects in method development
    Havlikova, Lucie
    Vlckova, Hana
    Solich, Petr
    Novakova, Lucie
    BIOANALYSIS, 2013, 5 (19) : 2345 - 2357
  • [44] Pre-column derivatization combined with UHPLC-MS/MS for rapid and sensitive quantification of bakuchiol in rat plasma
    Zhuang, Xiaomei
    Zhong, Yuhuan
    Yuan, Mei
    Li, Hua
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2013, 75 : 18 - 24
  • [45] Vertical Ultrafiltration-Facilitated DNA Digestion for Rapid and Sensitive UHPLC-MS/MS Detection of DNA Modifications
    Lai, Weiyi
    Lyu, Cong
    Wang, Hailin
    ANALYTICAL CHEMISTRY, 2018, 90 (11) : 6859 - 6866
  • [46] Simple and rapid quantification of vancomycin in serum, urine and peritoneal/pleural effusion via UHPLC-MS/MS applicable to personalized antibiotic dosing
    Javorska, Lenka
    Krcmova, Lenka Kujovska
    Solich, Petr
    Kaska, Milan
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2017, 142 : 59 - 65
  • [47] Determination of new psychoactive substances and other drugs in postmortem blood and urine by UHPLC-MS/MS: method validation and analysis of forensic samples
    Ferrari Junior, Ettore
    Caldas, Eloisa Dutra
    FORENSIC TOXICOLOGY, 2022, 40 (01) : 88 - 101
  • [48] Development and Validation of a UHPLC-MS/MS-Based Method to Quantify Cenobamate in Human Plasma Samples
    Charlier, Bruno
    Coglianese, Albino
    Operto, Francesca Felicia
    Coppola, Giangennaro
    de Grazia, Ugo
    Menna, Pierantonio
    Filippelli, Amelia
    Dal Piaz, Fabrizio
    Izzo, Viviana
    MOLECULES, 2022, 27 (21):
  • [49] Analysis of β2-agonists in cattle hair samples using a rapid UHPLC-ESI-MS/MS method
    Di Stefano, Vita
    Pitonzo, Rosa
    Giaccone, Vita
    Alongi, Angelina
    Macaluso, Andrea
    Cicero, Nicola
    Cancemi, Gabriella
    Ferrantelli, Vincenzo
    NATURAL PRODUCT RESEARCH, 2017, 31 (04) : 482 - 486
  • [50] A UHPLC-MS/SRM method for analysis of phenolics from Camellia sinensis leaves from Nilgiri hills
    Ramakrishnan, Padma
    Rangiah, Kannan
    ANALYTICAL METHODS, 2016, 8 (45) : 8033 - 8041