Sensitive and Rapid UHPLC-MS/MS for the Analysis of Tomato Phenolics in Human Biological Samples

被引:15
|
作者
Martinez-Huelamo, Miriam [1 ,2 ]
Tulipani, Sara [3 ]
Jauregui, Olga [4 ]
Valderas-Martinez, Palmira [2 ,5 ]
Vallverdu-Queralt, Anna [2 ,6 ]
Estruch, Ramon [2 ,5 ]
Torrado, Xavier [1 ]
Lamuela-Raventos, Rosa M. [1 ,2 ]
机构
[1] Univ Barcelona, Dept Nutr & Food Sci XARTA INSA, Sch Pharm, E-08028 Barcelona, Spain
[2] Carlos III Hlth Inst, Ctr Biomed Network Res Pathophysiol Obes & Nutr C, Madrid 28029, Spain
[3] Univ Malaga, Hosp Virgen Victoria, Biomed Res Inst IBIMA, Serv Endocrinol & Nutr, Malaga 29010, Spain
[4] Univ Barcelona CCiTUB, Ctr Sci & Technol, Barcelona 08028, Spain
[5] Univ Barcelona, Dept Internal Med, Hosp Clin, Inst Biomed Invest August Pi I Sunyer IDIBAPS, E-08028 Barcelona, Spain
[6] INRA, Sci Oenol UMR1083, F-34060 Montpellier, France
关键词
polyphenol metabolites; validation; tomato; sauce; microbiota; metabolites; biosamples; blood; urine; PERFORMANCE LIQUID-CHROMATOGRAPHY; POLYPHENOL-RICH FOODS; MASS-SPECTROMETRY; CAPILLARY-ELECTROPHORESIS; BIOACTIVE COMPOUNDS; URINARY-EXCRETION; UPLC; METABOLITES; VALIDATION; ACIDS;
D O I
10.3390/molecules201119702
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
An UHPLC-MS/MS method for the quantification of tomato phenolic metabolites in human fluids was optimized and validated, and then applied in a pilot dietary intervention study with healthy volunteers. A 5-fold gain in speed (3.5 min of total run); 7-fold increase in MS sensitivity and 2-fold greater efficiency (50% peak width reduction) were observed when comparing the proposed method with the reference-quality HPLC-MS/MS system, whose assay performance has been previously documented. The UHPLC-MS/MS method led to an overall improvement in the limits of detection (LOD) and quantification (LOQ) for all the phenolic compounds studied. The recoveries ranged between 68% and 100% in urine and 61% and 100% in plasma. The accuracy; intra- and interday precision; and stability met with the acceptance criteria of the AOAC International norms. Due to the improvements in the analytical method; the total phenolic metabolites detected in plasma and urine in the pilot intervention study were 3 times higher than those detected by HPLC-MS/MS. Comparing with traditional methods; which require longer time of analysis; the methodology described is suitable for the analysis of phenolic compounds in a large number of plasma and urine samples in a reduced time frame.
引用
收藏
页码:20409 / 20425
页数:17
相关论文
共 50 条
  • [31] Development of a UHPLC-MS/MS method for the determination of plasma histamine in various mammalian species
    Liu, Jia
    Wang, Lei
    Hu, Wenjuan
    Chen, Xiaoyan
    Zhong, Dafang
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 971 : 35 - 42
  • [32] Fabric phase sorptive extraction followed by UHPLC-MS/MS for the analysis of benzotriazole UV stabilizers in sewage samples
    Montesdeoca-Esponda, Sarah
    Sosa-Ferrera, Zoraida
    Kabir, Abuzar
    Furton, Kenneth G.
    Juan Santana-Rodriguez, Jose
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2015, 407 (26) : 8137 - 8150
  • [33] UHPLC-MS/MS method for the determination of azithromycin in human plasma of pediatric patients
    Cai, Ningfang
    Wu, Xiuping
    Lin, Jiancheng
    Zou, Jialiang
    Yi, Jin Ling
    Luo, Xi
    BIOMEDICAL CHROMATOGRAPHY, 2022, 36 (09)
  • [34] Determination of Antidepressants in Hair via UHPLC-MS/MS as a Complementary Informative Tool for Clinical and Forensic Toxicological Assessments
    Fernandez, Mara del Mar Ramirez
    Wille, Sarah M. R.
    Hill, Virginia
    Samyn, Nele
    THERAPEUTIC DRUG MONITORING, 2016, 38 (06) : 751 - 760
  • [35] UHPLC-MS/MS method for simultaneously detecting 16 tryptamines and their metabolites in human hair and applications to real forensics cases
    Shi, Yan
    Wang, Roujia
    Yuan, Shuai
    Qiang, Huosheng
    Shen, Min
    Shen, Baohua
    Drummer, Olaf H.
    Yu, Zhiguo
    Zhao, Yunli
    Xiang, Ping
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2020, 1159
  • [36] Chemometric Optimization of SPE for the Determination of Multiclass Pesticides in Portable Water Samples by UHPLC-MS/MS
    Drimaropoulou, Garyfallia
    Christophoridis, Christophoros
    Zacharis, Constantinos K.
    Fytianos, Konstantinos
    BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 2024, 112 (03)
  • [37] Identification of mycotoxins in yogurt samples using an optimized QuEChERS extraction and UHPLC-MS/MS detection
    Rodriguez-Canas, Ines
    Gonzalez-Jartin, Jesus M.
    Alvarino, Rebeca
    Alfonso, Amparo
    Vieytes, Mercedes R.
    Botana, Luis M.
    MYCOTOXIN RESEARCH, 2024, 40 (04) : 569 - 579
  • [38] Development and validation of an UHPLC-MS/MS method for β2-agonists quantification in human urine and application to clinical samples
    Bozzolino, Cristina
    Leporati, Marta
    Gani, Federica
    Ferrero, Cinzia
    Vincenti, Marco
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2018, 150 : 15 - 24
  • [39] Assessment of 83 pharmaceuticals in WWTP influent and effluent samples by UHPLC-MS/MS: Hourly variation
    Paiga, Paula
    Correia, Manuela
    Fernandes, Maria Joao
    Silva, Ana
    Carvalho, Manuela
    Vieira, Joana
    Jorge, Sandra
    Silva, Jaime Gabriel
    Freire, Cristina
    Delerue-Matos, Cristina
    SCIENCE OF THE TOTAL ENVIRONMENT, 2019, 648 : 582 - 600
  • [40] Development of Paraquat Pesticide Determination Methodology in Urine Samples by UHPLC-MS/MS
    de Melo, Karolyne Gramlich
    de Souza e Silva, Gabriela Trindade
    dos Santos, Andre Danioti
    Dolores, Raul Cleverson
    Oliveira, Francisca
    Trape, Angelo Zanaga
    Pires Rosa, Paulo Cesar
    BRAZILIAN JOURNAL OF ANALYTICAL CHEMISTRY, 2022, 9 (35): : 76 - 85