Spectrophotometric flow-injection determination of copper and nickel in plant digests exploiting differential kinetic analysis and multi-site detection

被引:20
作者
Vendramini, Diego [1 ]
Grassi, Viviane [1 ]
Zagatto, Elias A. G. [1 ]
机构
[1] Univ Sao Paulo, Ctr Energia Nucl & Agr, BR-13400970 Piracicaba, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
differential kinetic analysis; flow analysis; multi-site detection; UV-vis spectrophotometry; plant analysis;
D O I
10.1016/j.aca.2006.04.008
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel strategy for implementing differential reaction-rate methods in flow-injection analysis is proposed and applied to the determination of copper and nickel in plant digests using 2-(5-brom-2-pyridylazo)-5-(diethylamino)-phenol (Br-PADAP) as the color-forming reagent. Multi-site detection is involved, therefore the flow cell is displaced between two monitoring sites, and the analytical signals refer to different conditions of sample dispersion, reaction development and timing. The system handles 20 samples h(-1) and requires 0.32 mg Br-PADAP per determination. Signal additivity was evaluated within 98 and 102%, and linear responses (r > 0.999; n = 6) were verified for both copper and nickel up to 0.80 mg l(-1). Detection limits of 0.01 and 0.04 mg l(-1) Cu and Ni were estimated by considering the highest concentration of the counter analyte. Results are precise (R.S.D. < 2%) and in agreement with ICP-OES (95% confidence level). Potentialities and limitations of the approach are discussed. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:124 / 128
页数:5
相关论文
共 15 条
[1]  
[Anonymous], 2012, BUFFERS PH METAL ION
[2]   Flow amperometric determination of pharmaceuticals with on-line electrode surface renewal [J].
Catarino, RIL ;
Conceiçao, ACL ;
Garcia, MBQ ;
Gonçalves, MLS ;
Lima, JLFC ;
dos Santos, MMC .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 33 (04) :571-580
[3]   A critical examination of the components of the Schlieren effect in flow analysis [J].
Dias, ACB ;
Borges, EP ;
Zagatto, EAG ;
Worsfold, PJ .
TALANTA, 2006, 68 (04) :1076-1082
[4]   Derivative spectrophotometric determination of nickel using Br-PADAP [J].
Ferreira, SLC ;
Costa, ACS ;
deJesus, DS .
TALANTA, 1996, 43 (10) :1649-1656
[5]   Flow-injection systems with multi-site detection [J].
Grassi, V ;
Zagatto, EAG ;
Lima, JLFC .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2005, 24 (10) :880-886
[6]  
JACINTHO AO, 1985, ANAL QUIMICA ROCHAS
[7]  
KELLNER R, 1998, ANAL CHEM, P236
[8]   The use of ion exchange resin for reagent immobilization and concentration in flow systems. Determination of nickel in steel alloys and iron speciation in waters [J].
Martelli, PB ;
Reis, BF ;
Korn, M ;
Rufini, IA .
JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 1997, 8 (05) :479-485
[9]  
Martin-Prevel P., 1987, PLANT ANAL GUIDE NUT, DOI [10.4060/cb7139-n, DOI 10.4060/CB7139-N]
[10]  
NETO JAG, 1994, ANAL CHIM ACTA, V285, P293