A critical evaluation of a flow-cell based on a liquid core waveguide for chemiluminescence measurements

被引:5
作者
Sanchez, Mariana A. [1 ]
Rocha, Fabio R. P. [1 ]
机构
[1] Univ Sao Paulo, Inst Quim, BR-05513970 Sao Paulo, Brazil
关键词
chemiluminescence; liquid-core waveguide; flow analysis; FIA; hypochlorite;
D O I
10.1002/bio.1071
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Liquid-core waveguides (LCWs), devices that constrain the emitted radiation minimizing losses during the transport, are an alternative to maximize the amount of detected radiation in luminescence. In this work, the performance of a LCW flow-cell was critically evaluated for chemiluminescence measurements, by using as model the oxidation of luminol by hydrogen peroxide or hypochlorite. An analytical procedure for hypochlorite determination was also developed, with linear response in the range 0.2-3.8 mg/L (2.7-51 mu mol/L), a detection limit estimated as 8 mu g/L (0.64 mu mol/L) at the 99.7% confidence level and luminol consumption of 50 mu g/determination. The coefficients of variation were 3.3% and 1.6% for 0.4 and 1.9 mg/L CIO-, respectively, with a sampling rate of 164 determinations/h. The procedure was applied to the analysis of Dakin's solution samples, yielding results in agreement with those obtained by iodometric titration at the 95% confidence level. Copyright (c) 2008 John Wiley & Sons, Ltd.
引用
收藏
页码:410 / 416
页数:7
相关论文
共 25 条
[1]   Forensic application of the luminol reaction as a presumptive test for latent blood detection [J].
Barni, Filippo ;
Lewis, Simon W. ;
Berti, Andrea ;
Miskelly, Gordon M. ;
Lago, Giampietro .
TALANTA, 2007, 72 (03) :896-913
[2]   Development of a low cost device for chemiluminescence measurements [J].
Borges, EP ;
Fernandes, EN ;
Rocha, FRP ;
Reis, BF .
QUIMICA NOVA, 2002, 25 (6B) :1191-1193
[3]  
CALATAYUD JM, 1996, FLOW INJECTION ANAL, P171
[4]   A new flow cell design for chemiluminiscence analysis [J].
Campíns-Falcó, P ;
Tortajada-Genaro, LA ;
Bosch-Reig, F .
TALANTA, 2001, 55 (02) :403-413
[5]   Light at the end of the tunnel: recent analytical applications of liquid-core waveguides [J].
Dallas, T ;
Dasgupta, PK .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2004, 23 (05) :385-392
[6]   Luminescence detection with a liquid care waveguide [J].
Dasgupta, PK ;
Zhang, GF ;
Li, JZ ;
Boring, CB ;
Jambunathan, S ;
Al-Horr, R .
ANALYTICAL CHEMISTRY, 1999, 71 (07) :1400-1407
[7]   Hypohalites and related oxidants as chemiluminescence reagents: a review [J].
Francis, PS ;
Barnett, NW ;
Lewis, SW ;
Lim, KF .
LUMINESCENCE, 2004, 19 (02) :94-115
[8]   Detector cell based on plastic liquid-core waveguides suitable for aqueous solutions: one-to-two decades improved detection limits in conventional-size column liquid chromatography with absorption detection [J].
Gooijer, C ;
Hoornweg, GP ;
de Beer, T ;
Bader, A ;
van Iperen, DJ ;
Brinkman, UAT .
JOURNAL OF CHROMATOGRAPHY A, 1998, 824 (01) :1-5
[9]   A critical evaluation of a long pathlength cell for flow-based spectrophotometric measurements [J].
Infante, Carlos M. C. ;
Rocha, Fabio R. P. .
MICROCHEMICAL JOURNAL, 2008, 90 (01) :19-25
[10]   A flow analysis experiment involving enzymatic reactions and chemiluminescence [J].
Leite, OD ;
Fatibello, O ;
Rocha, FRP .
QUIMICA NOVA, 2004, 27 (02) :337-341