共 50 条
Novel capsule phase microextraction in combination with liquid chromatography-tandem mass spectrometry for determining personal care products in environmental water
被引:18
|作者:
Lakade, Sameer S.
[1
]
Borrull, Francesc
[1
]
Furton, Kenneth G.
[2
]
Kabir, Abuzar
[2
]
Maria Marce, Rosa
[1
]
Fontanals, Nuria
[1
]
机构:
[1] Univ Rovira & Virgili, Dept Analyt Chem & Organ Chem, Sescelades Campus,Marcelli Domingo S-N, E-43007 Tarragona, Spain
[2] Florida Int Univ, Dept Chem & Biochem, Int Forens Res Inst, Miami, FL 33199 USA
关键词:
Capsule phase microextraction;
Microextraction capsule;
Liquid chromatography-tandem mass spectrometry;
Personal care products;
Environmental water samples;
BAR SORPTIVE EXTRACTION;
UV-FILTERS;
EMERGING CONTAMINANTS;
WASTE-WATER;
UHPLC-MS/MS;
SAMPLES;
PHARMACEUTICALS;
STABILIZERS;
TRICLOSAN;
D O I:
10.1007/s00216-018-0984-z
中图分类号:
Q5 [生物化学];
学科分类号:
071010 ;
081704 ;
摘要:
A novel sample preparation technique named capsule phase microextraction (CPME) is presented here. The technique utilizes a miniaturized microextraction capsule (MEC) as the extraction medium. The MEC consists of two conjoined porous tubular polypropylene membranes, one of which encapsulates the sorbent through sol-gel technology, while the other encapsulates a magnetic metal rod. As such, MEC integrates both the extraction and stirring mechanisms into a single device. The aim of this article is to demonstrate the application potential of CPME as sample preparation technique for the extraction of a group of personal care products (PCPs) from water matrices. Among the different sol-gel sorbent materials (UCONA (R), poly(caprolactone-dimethylsiloxane-caprolactone) (PCAP-DMS-CAP) and Carbowax 20M (CW-20M)) evaluated, CW-20M MEC demonstrated the best extraction performance for the selected PCPs. The extraction conditions for sol-gel CW-20M MEC were optimized, including sample pH, stirring speed, addition of salt, extraction time, sample volume, liquid desorption solvent, and time. Under the optimal conditions, sol-gel CW-20M MEC provided recoveries, ranging between 47 and 90% for all analytes, except for ethylparaben, which showed a recovery of 26%. The method based on CPME with sol-gel CW-20M followed by liquid chromatography-tandem mass spectrometry was developed and validated for the extraction of PCPs from river water and effluent wastewater samples. When analyzing different environmental samples, some analytes such as 2,4-dihydroxybenzophenone, 2,2-dihydroxy-4-4 methoxybenzophenone and 3-benzophenone were found at low ng L-1.
引用
收藏
页码:2991 / 3001
页数:11
相关论文