Atomization of hydride with a low-temperature, atmospheric pressure dielectric barrier discharge and its application to arsenic speciation with atomic absorption spectrometry

被引:122
作者
Zhu, ZL [1 ]
Zhang, SC [1 ]
Lv, Y [1 ]
Zhang, XR [1 ]
机构
[1] Tsing Hua Univ, Dept Chem, Key Lab Atom & Mol Nanosci, Educ Minist, Beijing 100084, Peoples R China
关键词
D O I
10.1021/ac051022c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper describes a novel hydride atomizer based on atmospheric pressure dielectric barrier discharge (DBD) plasma. The plasma was generated with a 3700-V, 20.3-kHz, and 5-W electrical power supply and easily sustained with inert gases (He or Ar) at a flow rate of 250 mL(.)min(-1) after optimization. However, it cannot be sustained with N-2. Ibis atomizer offers the advantages of low operation temperature and low power consumption in comparison with the currently used electrothermal quartz atornization operated at 900 degrees C with a power supply of several hundred watts. To confirm the utility of the proposed atomizer, four arsenic species (As(III), As(V), monomethylarsonic acid (MMA), dimethylarsinic acid (DMA)) were determined by the present atornization technique. A hyphenation of HPLC coupled to hydride generation AAS with the optimized DBD atomizer has been successfully used for the speciation of arsenic in order to demonstrate the potential of this atomizer in the present study. The characteristics of the DBD atomizer and the effects of different parameters (discharge gas, gas flow rate, voltage, HCl concentration, KBH4 concentration) are discussed in the paper. Compared with other hydride atornization techniques, the proposed method shows the following features: (1) small size (70 mm x 15 mm x 5 mm), which is preferable for the miniaturization of the total analytical system; (2) low power consumption (:55 W), which indicates the possibility of the development of portable, fieldable analytical instrumentation for in situ detection using battery as power supply; (3) low atomizer temperature (similar to 70 degrees C), which is in favor of the compactness of the total instruments; (4) avoidance of residue moisture removal in comparison with the existed GD system, which leads to the facility of the system. The analytical figures of the present technique were evaluated. The detection limits of As(III), As(V), MMA, and DMA obtained with HG-DBD-AAS were 1.0, 11.8, 2.0, and 18.0 mu g(.)L(-1), respectively. The accuracy of the system was verified by the determination of arsenic in reference material of orchard leaves SRM 1571,. The concentration of As determined by the present method agreed well with the reference values. The speciation of arsenic in the freeze-dried urine SRM 2670 were carried out, and the results obtained were in agreement with the results of HPLC-ICPMS and the reported values by other laboratories.
引用
收藏
页码:865 / 872
页数:8
相关论文
共 50 条
  • [1] Generation of tellurium hydride and its atomization in a dielectric barrier discharge for atomic absorption spectrometry
    Bufkova, Katerina
    Musil, Stanislav
    Kratzer, Jan
    Dvorak, Pavel
    Mrkvickova, Martina
    Vorac, Jan
    Dedina, Jiri
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2020, 171
  • [2] Preconcentration and Atomization of Arsane in a Dielectric Barrier Discharge with Detection by Atomic Absorption Spectrometry
    Novak, Petr
    Dedina, Jiri
    Kratzer, Jan
    ANALYTICAL CHEMISTRY, 2016, 88 (11) : 6064 - 6070
  • [3] Application of atmospheric pressure dielectric barrier discharge plasma for the determination of Se, Sb and Sn with atomic absorption spectrometry
    Zhu, Zhenli
    Zhang, Sichun
    Xue, Junhai
    Zhang, Xinrong
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2006, 61 (08) : 916 - 921
  • [4] Mechanism of Arsenic Hydride Generation and Atomization in Low Temperature Atomic Fluorescence Spectrometry
    Ren, Ping
    Zhou, Liyi
    Zhang, Qin
    Guang Pu Xue Yu Guang Pu Fen Xi/Spectroscopy and Spectral Analysis, 19 (02): : 199 - 200
  • [5] Mechanism of arsenic hydride generation and atomization in low temperature atomic fluorescence spectrometry
    Ren, P
    Zhou, LY
    Zhang, Q
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 1999, 19 (02) : 198 - 199
  • [6] Trace determination of antimony by hydride generation atomic absorption spectrometry with analyte preconcentration/atomization in a dielectric barrier discharge atomizer
    Zurynkova, Pavla
    Dedina, Jiri
    Kratzer, Jan
    ANALYTICA CHIMICA ACTA, 2018, 1010 : 11 - 19
  • [7] Low-Temperature and Atmospheric Pressure Sample Digestion Using Dielectric Barrier Discharge
    Luo, Yijing
    Yang, Yuan
    Lin, Yao
    Tian, Yunfei
    Wu, Li
    Yang, Lu
    Hou, Xiandeng
    Zheng, Chengbin
    ANALYTICAL CHEMISTRY, 2018, 90 (03) : 1547 - 1553
  • [8] Atomization of lead hydride in a dielectric barrier discharge atomizer: Optimized for atomic absorption spectrometry and studied by laser-induced fluorescence
    Albrecht, Michal
    Mrkvickova, Martina
    Svoboda, Milan
    Hranieck, Jakub
    Vorac, Jan
    Dvorak, Pavel
    Dedina, Jiri
    Kratzer, Jan
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2020, 166
  • [9] Speciation of inorganic arsenic by electrochemical hydride generation atomic absorption spectrometry
    Li, X
    Jia, J
    Wang, ZH
    ANALYTICA CHIMICA ACTA, 2006, 560 (1-2) : 153 - 158
  • [10] Skin decontamination by low-temperature atmospheric pressure plasma jet and dielectric barrier discharge plasma
    Daeschlein, G.
    Scholz, S.
    Ahmed, R.
    von Woedtke, T.
    Haase, H.
    Niggemeier, M.
    Kindel, E.
    Brandenburg, R.
    Weltmann, K. -D.
    Juenger, M.
    JOURNAL OF HOSPITAL INFECTION, 2012, 81 (03) : 177 - 183