We demonstrate that chemical-shift-selective constant-time imaging (CTI) can be performed by simply inserting selective saturation into the original imaging pulse sequence. The performance of the proposed method is illustrated by Li-7 CTI imaging in a battery model that contains both Li metal electrodes and an electrolyte containing a dissolved Li salt. (C) 2012 Elsevier Inc. All rights reserved.
引用
收藏
页码:19 / 21
页数:3
相关论文
共 50 条
  • [41] CHEMICAL-SHIFT CHEMICAL-SHIFT CORRELATION SPECTROSCOPY IN POWDERED SOLIDS
    HUGHES, CD
    SHERWOOD, MH
    ALDERMAN, DW
    GRANT, DM
    JOURNAL OF MAGNETIC RESONANCE SERIES A, 1993, 102 (01) : 58 - 72
  • [42] Constant-time sorting
    Brand, Michael
    INFORMATION AND COMPUTATION, 2014, 237 : 142 - 150
  • [43] CHEMICAL-SHIFT IMAGING OF PARTICLE FILTRATION IN SANDSTONE CORES
    STRALEY, C
    ROSSINI, D
    SCHWARTZ, LM
    STROMSKI, ME
    HROVAT, M
    PATZ, S
    MAGNETIC RESONANCE IMAGING, 1994, 12 (02) : 313 - 315
  • [44] FAST GRADIENT-ECHO CHEMICAL-SHIFT IMAGING
    PARK, HW
    KIM, YH
    CHO, ZH
    MAGNETIC RESONANCE IN MEDICINE, 1988, 7 (03) : 340 - 345
  • [45] Chemical-shift micro-imaging of subcutaneous lesions
    Weis, J
    Åström, G
    Vinnars, B
    Wanders, A
    Ahlström, H
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2005, 18 (02) : 59 - 62
  • [46] PITUITARY FOSSA - CHEMICAL-SHIFT EFFECT IN MR IMAGING
    HAUGHTON, VM
    PROST, R
    RADIOLOGY, 1986, 158 (02) : 461 - 462
  • [47] Reduced spatial side lobes in chemical-shift imaging
    Adalsteinsson, E
    Star-Lack, J
    Meyer, CH
    Spielman, DM
    MAGNETIC RESONANCE IN MEDICINE, 1999, 42 (02) : 314 - 323
  • [48] CHEMICAL-SHIFT IMAGING OF ATHEROSCLEROSIS AT 7.0-TESLA
    MAYNOR, CH
    CHARLES, HC
    HERFKENS, RJ
    SUDDARTH, SA
    JOHNSON, GA
    INVESTIGATIVE RADIOLOGY, 1989, 24 (01) : 52 - 60
  • [49] Chemical-shift micro-imaging of subcutaneous lesions
    J. Weis
    G. Åström
    B. Vinnars
    A. Wanders
    H. Ahlström
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2005, 18 : 59 - 62
  • [50] CHEMICAL-SHIFT IMAGING OF FLUID FILLED POROUS ROCKS
    DEREPPE, JM
    MOREAUX, C
    SCHENKER, K
    MAGNETIC RESONANCE IMAGING, 1991, 9 (05) : 809 - 813