A survey of preferences and practices of endometrial ablation/resection for menorrhagia in the United Kingdom

被引:16
作者
Deb, Shilla [1 ]
Flora, Kulwant [2 ]
Atiomo, William [2 ]
机构
[1] Univ Nottingham Hosp, Dept Obstet & Gynecol, Nottingham, England
[2] Univ Nottingham, Sch Human Dev, Dept Obstet & Gynecol, Nottingham NG7 2RD, England
关键词
Endometrial ablation; questionnaire; menorrhagia; endometrial resection;
D O I
10.1016/j.fertnstert.2007.08.052
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: To survey the preferences and variations in the current use of first- and second-generation endometrial ablative techniques for menorrhagia among the consultant gynecologists in the United Kingdom, given the call for further studies to systematically compare the clinical effectiveness of the various endometrial ablation techniques. Design: Postal questionnaire survey. Population: One thousand, four hundred sixty consultant gynecologists in the United Kingdom. Main Outcome Measure(s): Preferred endometrial ablation/resection method and variations in the current practices. Result(s): Six hundred ten (41%) consultants responded. Of these, 449 (73%) performed endometrial ablation/resection. Thermal balloon ablation (32.1%) was the preferred method, followed by microwave endometrial ablation (29.8%), transcervical resection of the endometrial alone or combined with roller ball diathermy (18.5%), Novasure (9.8%), hydrotherm ablation (6.9%), roller ball (2%), and laser (0.9%). Patient response to treatment was assessed using clinical history (64.3%), menstrual calendar (7.6%), clinical history and menstrual calendar (21.3%), questionnaires (5.8%), and pictorial blood loss assessment charts (0.4%). A total of 52.2% used gonadotrophin releasing hormone analogues preoperatively. Variations in techniques for transcervical resection of the endometrial included methods used to treat the uterine fundus and cornuae, fluid management, and operating pressures. Conclusion(s): Second-generation endometrial ablation devices were preferred to first-generation devices for the management of menorrhagia. Thermal balloon ablation was the most preferred method. However, variations in surgical practices will make assessment of clinical efficacy a challenge. (Fertil Steril((R)) 2008;90:1812-7. (c) 2008 by American Society for Reproductive Medicine.)
引用
收藏
页码:1812 / 1817
页数:6
相关论文
共 24 条
[1]   A double-blind randomized trial comparing the Cavaterm™ and the NovaSure™ endometrial ablation systems for the treatment of dysfunctional uterine bleeding [J].
Abbott, J ;
Hawe, J ;
Hunter, D ;
Garry, R .
FERTILITY AND STERILITY, 2003, 80 (01) :203-208
[2]  
[Anonymous], COCHRANE DATABASE SY, DOI DOI 10.1002/14651858.CD001124
[3]   Bipolar radio frequency endometrial ablation compared with balloon endometrial ablation in dysfunctional uterine bleeding:: Impact on patients' health-related quality of life [J].
Bongers, MY ;
Bourdrez, P ;
Heintz, APM ;
Brölmann, HAM ;
Mol, BWJ .
FERTILITY AND STERILITY, 2005, 83 (03) :724-734
[4]   A randomized, multicenter trial of safety and efficacy of the NovaSure system in the treatment of menorrhagia [J].
Cooper, J ;
Gimpelson, R ;
Laberge, P ;
Galen, D ;
Garza-Leal, JG ;
Scott, J ;
Leyland, N ;
Martyn, P ;
Liu, J .
JOURNAL OF THE AMERICAN ASSOCIATION OF GYNECOLOGIC LAPAROSCOPISTS, 2002, 9 (04) :418-428
[5]   A randomised comparison of microwave endometrial ablation with transcervical resection of the endometrium; follow up at a minimum of five years [J].
Cooper, KG ;
Bain, C ;
Lawrie, L ;
Parkin, DE .
BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2005, 112 (04) :470-475
[6]   Increasing response rates to postal questionnaires: systematic review [J].
Edwards, P ;
Roberts, I ;
Clarke, M ;
DiGuiseppi, C ;
Pratap, S ;
Wentz, R ;
Kwan, I .
BRITISH MEDICAL JOURNAL, 2002, 324 (7347) :1183-1185
[7]   NovaSure impedance controlled system for endometrial ablation: Three-year follow-up on 107 patients [J].
Gallinat, A .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2004, 191 (05) :1585-1589
[8]   Microwave and thermal balloon ablation for heavy menstrual bleeding: a systematic review [J].
Garside, R ;
Stein, K ;
Wyatt, K ;
Round, A .
BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2005, 112 (01) :12-23
[9]  
Garside R, 2004, HEALTH TECHNOL ASSES, V8, P1
[10]   Evaluation of HydroThermAblator and rollerball endometrial ablation for menorrhagia 3 years after treatment [J].
Goldrath, MH .
JOURNAL OF THE AMERICAN ASSOCIATION OF GYNECOLOGIC LAPAROSCOPISTS, 2003, 10 (04) :505-511