A simple and sensitive electrochemical aptasensor for determination of Chloramphenicol in honey based on target-induced strand release

被引:73
作者
Yan, Li [1 ]
Luo, Caihui [1 ]
Cheng, Wei [2 ]
Mao, Wei [3 ]
Zhang, Decai [1 ]
Ding, Shijia [1 ]
机构
[1] Chongqing Med Univ, Coll Lab Med, Minist Educ China, Key Lab Clin Lab Diagnost, Chongqing 400016, Peoples R China
[2] Chongqing Med Univ, Affiliated Hosp 1, Mol Oncol & Epigenet Lab, Chongqing 400016, Peoples R China
[3] Chongqing Blood Ctr, Chongqing 400015, Peoples R China
基金
中国国家自然科学基金;
关键词
Aptamer; Electrochemical biosensor; Chloramphenicol; LIQUID-CHROMATOGRAPHY; GAS-CHROMATOGRAPHY; FLORFENICOL AMINE; RESIDUES; THIAMPHENICOL; SHRIMP; IMMUNOSENSOR; EXTRACTION; BIOSENSOR; SENSORS;
D O I
10.1016/j.jelechem.2012.10.016
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel electrochemical aptasensor for highly sensitive detection of Chloramphenicol (CAP) in honey was successfully developed based on target-induced strand release (TISR). CAP aptamer was immobilized on electrode and then hybridized with the complementary biotinylated detection probe to form aptamer/DNA duplex. In the presence of CAP, the TISR resulted in the dissociation of biotinylated detection probe from the electrode. Then the binding of streptavidin-alkaline phosphatase (ST-AP) to the remaining biotinylated detection probe led to enzyme-amplified electrochemical signal, which decreased with the increase of CAP concentration. Under optimal conditions, the electrochemical signal was linear with the logarithm of CAP concentrations in the range from 1 nM to 1000 nM with the detection limit of 0.29 nM of CAP. In addition, the designed strategy allowed the direct analysis of real honey samples and the results showed a good agreement with conventional LC-MS/MS method. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:89 / 94
页数:6
相关论文
共 36 条
[31]   Methylene blue as an indicator for sensitive electrochemical detection of adenosine based on aptamer switch [J].
Wang, Jianlong ;
Wang, Fuan ;
Dong, Shaojun .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2009, 626 (1-2) :1-5
[32]   Determination of oxytetracycline, tetracycline and chloramphenicol antibiotics in animal feeds using subcritical water extraction and high performance liquid chromatography [J].
Wang, Linling ;
Yang, Hai ;
Zhang, Chunwei ;
Mo, Yulin ;
Lu, Xiaohua .
ANALYTICA CHIMICA ACTA, 2008, 619 (01) :54-58
[33]   Sensitive voltammetric determination of chloramphenicol by using single-wall carbon nanotube-gold nanoparticle-ionic liquid composite film modified glassy carbon electrodes [J].
Xiao, Fei ;
Zhao, Faqiong ;
Li, Jiangwen ;
Yan, Rui ;
Yu, Jingjing ;
Zeng, Baizhao .
ANALYTICA CHIMICA ACTA, 2007, 596 (01) :79-85
[34]   A reagentless signal-on architecture for electronic, aptamer-based sensors via target-induced strand displacement [J].
Xiao, Y ;
Piorek, BD ;
Plaxco, KW ;
Heeger, AJ .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2005, 127 (51) :17990-17991
[35]   Target-induced strand release (TISR) from aptamer-DNA duplex: A general strategy for electronic detection of biomolecules ranging from a small molecule to a large protein [J].
Yoshizumi, Jyun ;
Kumamoto, Satoshi ;
Nakamura, Mitsunobu ;
Yamana, Kazushige .
ANALYST, 2008, 133 (03) :323-325
[36]   A new kind of aptamer-based immunomagnetic electrochemiluminescence assay for quantitative detection of protein [J].
Zhu, Debin ;
Zhou, Xiaoming ;
Xing, Da .
BIOSENSORS & BIOELECTRONICS, 2010, 26 (01) :285-288