Evaluation of the Effect of Hemoglobin or Hematocrit Level on Dural Sinus Density Using Unenhanced Computed Tomography

被引:12
作者
Lee, Seung Young [1 ]
Cha, Sang-Hoon [1 ]
Lee, Sung-Hyun [2 ]
Shin, Dong-Ick [2 ]
机构
[1] Chungbuk Natl Univ, Coll Med, Dept Radiol, Cheongju 361711, South Korea
[2] Chungbuk Natl Univ, Coll Med, Dept Neurol, Cheongju 361711, South Korea
关键词
Dural sinus; density; CT; hemoglobin; hematocrit; SUPERIOR SAGITTAL SINUS; DIAGNOSTIC-VALUE; NONCONTRAST CT; THROMBOSIS; ANEMIA; DISEASE; STROKE; SIGN;
D O I
10.3349/ymj.2013.54.1.28
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: To identify the relationship between hemoglobin (Hgb) or hematocrit (Hct) level and dural sinus density using unenhanced computed tomography (UECT). Materials and Methods: Patients who were performed UECT and had records of a complete blood count within 24 hours from UECT were included (n=122). We measured the Hounsfield unit (HU) of the dural sinus at the right sigmoid sinus, left sigmoid sinus and 2 points of the superior sagittal sinus. Quantitative measurement of dural sinus density using the circle regions of interest (ROI) method was calculated as average ROI values at 3 or 4 points. Simple regression analysis was used to evaluate the correlation between mean HU and Hgb or mean HU and Hct. Results: The mean densities of the dural sinuses ranged from 24.67 to 53.67 HU (mean, 43.28 HU). There was a strong correlation between mean density and Hgb level (r=0.832) and between mean density and Hct level (r=0.840). Conclusion: Dural sinus density on UECT is closely related to Hgb and Hct levels. Therefore, the Hgb or Hct levels can be used to determine whether the dural sinus density is within the normal range or pathological conditions such as venous thrombosis.
引用
收藏
页码:28 / 33
页数:6
相关论文
共 50 条
  • [31] Evaluation of the relationship between maxillary sinus floor position and maxillary sinusitis using cone beam computed tomography
    Yildirim, Eren
    Ciftci, Mehmet Ertugrul
    Kamak, Gulen
    Aktan, Ali Murat
    ORAL RADIOLOGY, 2017, 33 (01) : 16 - 22
  • [32] Improvement of detection of hypoattenuation in acute ischemic stroke in unenhanced computed tomography using an adaptive smoothing filter
    Takahashi, N.
    Lee, Y.
    Tsai, D. -Y.
    Ishii, K.
    Kinoshita, T.
    Tamura, H.
    Kimura, M.
    ACTA RADIOLOGICA, 2008, 49 (07) : 816 - 826
  • [33] Quantitative Comparison of Cone Beam Computed Tomography and Microradiography in the Evaluation of Bone Density after Maxillary Sinus Augmentation: A Preliminary Study
    Soardi, Carlo M.
    Zaffe, Davide
    Motroni, Alessandro
    Wang, Hom-Lay
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2014, 16 (04) : 557 - 564
  • [34] Effect of thinning on density of Pinus nigra tree using X-ray computed tomography
    Uner, B.
    Oyar, O.
    Var, A. A.
    Altnta, O. L.
    JOURNAL OF ENVIRONMENTAL BIOLOGY, 2009, 30 (03) : 359 - 362
  • [35] Role of the Sagittal View of Computed Tomography in Evaluation of the Nasofrontal Ducts in Frontal Sinus Fractures
    Jain, Sonu A.
    Manchio, Jeffrey V.
    Weinzweig, Jeffrey
    JOURNAL OF CRANIOFACIAL SURGERY, 2010, 21 (06) : 1670 - 1673
  • [36] 3D-evaluation of the maxillary sinus in cone-beam computed tomography
    Luz, Julia
    Greutmann, Dominique
    Wiedemeier, Daniel
    Rostetter, Claudio
    Ruecker, Martin
    Stadlinger, Bernd
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2018, 4
  • [37] Evaluation of the relationship between maxillary posterior teeth and the maxillary sinus floor using cone-beam computed tomography
    Gu, Yechen
    Sun, Chao
    Wu, Daming
    Zhu, Qingping
    Leng, Diya
    Zhou, Yang
    BMC ORAL HEALTH, 2018, 18
  • [38] Virtual unenhanced images derived from dual-energy computed tomography for assessing bone mineral density and detecting osteoporosis
    Tong, Xiaoyu
    Fang, Xin
    Wang, Shigeng
    Fan, Yong
    Wei, Wei
    Xiao, Qingzhu
    Chen, Anliang
    Liu, Yijun
    Liu, Lei
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (10) : 6571 - 6582
  • [39] Evaluation of maxillary sinus volumes and pathologies in children with and without cleft lip and palate using cone beam computed tomography
    Altun, Busra Dilara
    Dumlu, Asim
    ORTHODONTICS & CRANIOFACIAL RESEARCH, 2024, 27 : 27 - 34
  • [40] Evaluation of dehiscences using cone beam computed tomography
    Ising, Nicholas
    Kim, Ki Beom
    Araujo, Eustaquio
    Buschang, Peter
    ANGLE ORTHODONTIST, 2012, 82 (01) : 122 - 130