Organ Movement Reduction in PET/CT using Dual-Gated Listmode Acquisition

被引:37
作者
Lang, Norbert [1 ]
Dawood, Mohammad [1 ]
Buether, Florian [1 ]
Schober, Otmar [1 ]
Schaefers, Michael [1 ]
Schaefers, Klaus [1 ]
机构
[1] Univ Klinikum Munster, Nukl Med Klin & Poliklin, Dept Nucl Med, D-48149 Munster, Germany
来源
ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK | 2006年 / 16卷 / 01期
关键词
PET/CT; list-mode; cardiac gating; respiratory gating;
D O I
10.1078/0939-3889-00296
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Imaging of moving organs using the PET leads to blurred images due to long acquisition times. Simultaneous cardiac and respiratory gating of list-mode PET/CT is evaluated with the aim to improve image quality and assess the organ movement. Methods: We performed a N-13 ammonia PET/CT scan with a human volunteer, using the Siemens Biograph Sensation 16 scanner with listmode acquisition. For ECG gating we used the scanner's integrated ECG device. Respiratory gating was done with the BioVet pneumatic sensor system. Results: The sorting of the list-mode data post acquisition produced the desired matrix of eight cardiac times eight respiratory images. Organ movement could be measured in the series of gated PET images. The quantitation of tracer uptake in the myocardium showed artifacts due to the CT-based attenuation correction. Conclusion: Double gating is feasible in human PET/CT scans using a list-mode-based scan protocol. The image quality can be enhanced using double gated list-mode acquisition in PET/CT. Attenuation correction protocols in PET using a single not gated fast CT introduces artifacts in moving organs.
引用
收藏
页码:93 / 100
页数:8
相关论文
共 16 条
[1]  
Beyer T, 2000, J NUCL MED, V41, P1369
[2]   Dual-modality PET/CT imaging: the effect of respiratory motion on combined image quality in clinical oncology [J].
Beyer, T ;
Antoch, G ;
Blodgett, T ;
Freudenberg, LF ;
Akhurst, T ;
Mueller, S .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2003, 30 (04) :588-596
[3]  
Boucher L, 2004, J NUCL MED, V45, P214
[4]  
Chin Bennett B, 2003, Mol Imaging Biol, V5, P57, DOI 10.1016/S1536-1632(03)00044-1
[5]  
Erdi YE, 2004, J NUCL MED, V45, P1287
[6]   Respiration-induced attenuation artifact at PET/CT: Technical considerations [J].
Goerres, GW ;
Burger, C ;
Kamel, E ;
Seifert, B ;
Kaim, AH ;
Buck, A ;
Buehler, TC ;
von Schulthess, GK .
RADIOLOGY, 2003, 226 (03) :906-910
[7]   Electrocardiographically gated 16-section CT of the thorax: Cardiac motion suppression [J].
Hofmann, LK ;
Zou, KH ;
Costello, P ;
Schoepf, UJ .
RADIOLOGY, 2004, 233 (03) :927-933
[8]   X-ray-based attenuation correction for positron emission tomography/computed tomography scanners [J].
Kinahan, PE ;
Hasegawa, BH ;
Beyer, T .
SEMINARS IN NUCLEAR MEDICINE, 2003, 33 (03) :166-179
[9]  
MathWorks, MATL
[10]  
Nehmeh SA, 2003, J NUCL MED, V44, P1644