Argon cluster ion sources for sputtering and secondary ion mass spectrometry use projectiles consisting of several hundreds of atoms, accelerated to 10-20 keV, and deposit their kinetic energy within the top few nanometers of the surface. For organic materials, the sputtering yield is high removing material to similar depth. Consequently, the exposed new surface is relatively damage free. It has thus been demonstrated on model samples that it is now really possible to perform dual beam depth profiling experiments in organic materials with this new kind of ion source. Here, this possibility has been tested directly on tissue samples, 14 mu m thick rat brain sections, allowing primary ion doses much larger than the so-called static secondary ion mass spectrometry (SIMS) limit and demonstrating the possibility to enhance the sensitivity of time-of-flight (TOF)-SIMS biological imaging. However, the depth analyses have also shown some variations of the chemical composition as a function of depth, particularly for cholesterol, as well as some possible matrix effects due to the presence or absence of this compound.
引用
收藏
页码:7745 / 7752
页数:8
相关论文
共 38 条
[1]   INTERFEROMETRIC ANALYSIS OF INTRASECTION AND INTERSECTION THICKNESS VARIABILITY ASSOCIATED WITH CRYOSTAT MICROTOMY [J].
ANTHONY, A ;
COLURSO, GJ ;
BOCAN, TMA ;
DOEBLER, JA .
HISTOCHEMICAL JOURNAL, 1984, 16 (01) :61-70
[2]   Mass spectrometry imaging of rat brain sections: nanomolar sensitivity with MALDI versus nanometer resolution by TOF-SIMS [J].
Benabdellah, Farida ;
Seyer, Alexandre ;
Quinton, Loic ;
Touboul, David ;
Brunelle, Alain ;
Laprevote, Olivier .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 396 (01) :151-162
[3]   IMPACT OF SLOW GOLD CLUSTERS ON VARIOUS SOLIDS - NONLINEAR EFFECTS IN SECONDARY ION EMISSION [J].
BENGUERBA, M ;
BRUNELLE, A ;
DELLANEGRA, S ;
DEPAUW, J ;
JORET, H ;
LEBEYEC, Y ;
BLAIN, MG ;
SCHWEIKERT, EA ;
BENASSAYAG, G ;
SUDRAUD, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1991, 62 (01) :8-22
[4]   ORGANIC FILM THICKNESS EFFECT IN SECONDARY ION MASS-SPECTROMETRY AND PLASMA DESORPTION MASS-SPECTROMETRY [J].
BOLBACH, G ;
VIARI, A ;
GALERA, R ;
BRUNOT, A ;
BLAIS, JC .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1992, 112 (01) :93-100
[5]   Biological tissue imaging with time-of-flight secondary ion mass spectrometry and cluster ion sources [J].
Brunelle, A ;
Touboul, D ;
Laprévote, O .
JOURNAL OF MASS SPECTROMETRY, 2005, 40 (08) :985-999
[6]   Enhanced secondary-ion emission under gold-cluster bombardment with energies from keV to MeV per atom [J].
Brunelle, A. ;
Della-Negra, S. ;
Depauw, J. ;
Jacquet, D. ;
Le Beyec, Y. ;
Pautrat, M. ;
Baudin, K. ;
Andersen, H.H. .
Physical Review A - Atomic, Molecular, and Optical Physics, 2001, 63 (02) :022902-022901
[7]  
Chen Y. Y., 2008, J ANAL CHEM+, V80, P510
[8]   Attempts for molecular depth profiling directly on a rat brain tissue section using fullerene and bismuth cluster ion beams [J].
Debois, Delphine ;
Brunelle, Alain ;
Laprevote, Olivier .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2007, 260 (2-3) :115-120
[9]   Secondary Ion Mass Spectrometry: Characterizing Complex Samples in Two and Three Dimensions [J].
Fletcher, John S. ;
Vickerman, John C. .
ANALYTICAL CHEMISTRY, 2013, 85 (02) :610-639
[10]  
Gilmore I. S., TOF SIMS SURFACE ANA