PHOTONEUTRON CONTAMINATION FROM AN 18 MV SATURNE MEDICAL LINEAR ACCELERATOR IN THE TREATMENT ROOM

被引:9
|
作者
Khosravi, Mostafa [1 ,2 ]
Shahbazi-Gahrouei, Daryoush [1 ]
Jabbari, Keyvan [1 ]
Nasri-Nasrabadi, Mehdi [3 ]
Baradaran-Ghahfarokhi, Milad [1 ]
Siavashpour, Zahra [4 ]
Gheisari, Ruhollah [2 ,5 ]
Amiri, Behnam [6 ]
机构
[1] Isfahan Univ Med Sci, Sch Med, Dept Med Phys & Med Engn, Esfahan, Iran
[2] Radiat & Pollut Protect Ctr Mamasani, Fars, Iran
[3] Univ Isfahan, Sch Adv Sci & Technol, Dept Nucl Engn, Esfahan, Iran
[4] Shahid Beheshti Univ, Dept Med Radiat Engn, Tehran, Iran
[5] Persian Gulf Univ, Sch Sci, Dept Phys, Booshehr, Iran
[6] Sharif Tecnol Univ, Dept Mech Engn, Tehran, Iran
关键词
MONTE-CARLO; RADIATION-THERAPY; SIEMENS; VARIAN; ENTRANCE; SPECTRA; LINACS; BEAMS; MODEL; CODE;
D O I
10.1093/rpd/nct078
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Dose escalation with high-energy X rays of medical linear accelerators (linacs) in radiotherapy offers several distinct advantages over the lower energy photons. However, owing to photoneutron reactions, interaction of high-energy photons (>8 MV) with various high-Z nuclei of the materials in the linac head components produces unavoidable neutrons. The aim of this study was to evaluate the photoneutron dose equivalent per unit therapeutic X-ray dose of 18 MV, GE Saturne 20 linac in the treatment room using Monte Carlo (MC) MCNP linac head full simulation as well as thermoluminescence dosemeter measurements. This machine is one of the old linac models manufactured by General Electric Company; however, it is widely used in the developing countries because of low cost and simple maintenance for radiotherapy applications. The results showed a significant photoneutron dose from Saturne 20 linac head components especially at distances near the linac head (<150 cm). Results of this work could be used in several applications, especially designing bunker and entrance door shielding against neutrons produced by photoneutron reactions in GE Saturne 20. However, a detailed cost optimisation for a specific room would require a dedicated calculation.
引用
收藏
页码:356 / 363
页数:8
相关论文
共 39 条
  • [1] INVESTIGATION OF PHOTONEUTRON CONTAMINATION FROM THE 18-MV PHOTON BEAM IN A MEDICAL LINEAR ACCELERATOR
    Karaman, Onur
    Tanir, Ayse Gunes
    Karaman, Ceren
    MATERIALI IN TEHNOLOGIJE, 2019, 53 (05): : 699 - 704
  • [2] New aspect determination of photoneutron contamination in 18 MV medical linear accelerator
    Mohammadi, A.
    Afarideh, H.
    Davani, F. Abbasi
    Arbabi, A.
    RADIATION MEASUREMENTS, 2016, 95 : 55 - 61
  • [3] GEANT4 Simulation of Photoneutron Spectrum from Medical Linear Accelerator
    Chernyaev, Alexander
    Belikhin, Mikhail
    Lykova, Ekaterina
    Shcherbakov, Alexey
    QUANTUM BEAM SCIENCE, 2023, 7 (03)
  • [4] Effect of wedge filter and field size on photoneutron dose equivalent for an 18 MV photon beam of a medical linear accelerator
    Mesbahi, Asghar
    Keshtkar, Ahmad
    Mohammadi, Ehsan
    Mohammadzadeh, Mohammad
    APPLIED RADIATION AND ISOTOPES, 2010, 68 (01) : 84 - 89
  • [5] EFFECTS OF FIELD SIZE AND DEPTH ON PHOTONEUTRON DOSE EQUIVALENT DISTRIBUTIONS IN AN 18 MV X-RAY MEDICAL ACCELERATOR
    Hakimi, Amir
    Sohrabi, Mehdi
    Mahdavi, Seied Rabie
    RADIATION PROTECTION DOSIMETRY, 2017, 176 (04) : 354 - 364
  • [6] MCNPX Estimation of Photoneutron Dose to Eye Voxel Anthropomorphic Phantom From 18 MV Linear Accelerator
    Alghamdi, Ali A. A.
    DOSE-RESPONSE, 2023, 21 (02):
  • [7] The effect of the flattening filter on photoneutron production at 10MV in the Varian TrueBeam linear accelerator
    Montgomery, Logan
    Evans, Michael
    Liang, Liheng
    Maglieri, Robert
    Kildea, John
    MEDICAL PHYSICS, 2018, 45 (10) : 4711 - 4719
  • [8] The influence of field size and off-axis distance on photoneutron spectra of the 18 MV Siemens Oncor linear accelerator beam
    Brkic, Hrvoje
    Ivkovic, Ana
    Kasabasic, Mladen
    Sovilj, Marina Poje
    Jurkovic, Slaven
    Stimac, Damir
    Rubin, Otmar
    Faj, Dario
    RADIATION MEASUREMENTS, 2016, 93 : 28 - 34
  • [9] Measurement of neutron yield for a medical linear accelerator below 10 MV
    Carlone, Marco
    Yang, Ray
    Hyde, Derek
    Becker, Nathan
    Cocarell, John
    MEDICAL PHYSICS, 2023, 50 (06) : 3338 - 3346
  • [10] Monte Carlo estimation of photoneutrons spectra and dose equivalent around an 18 MV medical linear accelerator
    Alem-Bezoubiri, A.
    Bezoubiri, F.
    Badreddine, A.
    Mazrou, H.
    Lounis-Mokrani, Z.
    RADIATION PHYSICS AND CHEMISTRY, 2014, 97 : 381 - 392