Role of Pulsatility in Hypothermic Reconditioning of Porcine Kidney Grafts by Machine Perfusion After Cold Storage

被引:68
作者
Gallinat, Anja [1 ]
Fox, Mario [2 ]
Lueer, Bastian [2 ]
Efferz, Patrik [2 ]
Paul, Andreas [1 ]
Minor, Thomas [2 ]
机构
[1] Univ Hosp Essen, Clin Gen Visceral & Transplantat Surg, Essen, Germany
[2] Univ Clin Surg, Div Surg Res, D-53127 Bonn, Germany
关键词
Machine perfusion; Pulsatility; Endothelium; Renovaculature; ENDOTHELIAL DYSFUNCTION; PRESERVATION; TRANSPLANTATION; DONORS; REPERFUSION; INJURY;
D O I
10.1097/TP.0b013e31829c24e2
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Background. Brief in-house machine perfusion after cold storage (CS) (hypothermic reconditioning) has been proposed as a convenient tool to improve kidney graft function. The present study aimed to investigate the mechanistic role of vascular pulsatility in this context. Methods. Kidney function after cold preservation (4 degrees C, 18 hr) and subsequent reconditioning by 90 min of pulsatile machine perfusion (PP) (30/20 mm Hg) or nonpulsatile machine perfusion (NPP) (30 mm Hg) was studied in an isolated kidney perfusion model in pigs (n=6 for both) and compared with simply CS grafts. Results. Compared with CS, PP but not NPP significantly improved renal perfusate flow and urine production and significantly increased the reduction of perfusate levels of creatinine and urea during reperfusion. Perfusate levels of fatty acid binding protein, a marker of tubular cell injury, were dramatically reduced by PP but not NPP. PP and NPP lowered fractional excretion of sodium, but significance was only reached for PP. Molecular effects of PP comprised a significant (vs. CS) mRNA elevation of the endothelial anti-inflammatory transcription factor Kruppel-like factor 2 as well as endothelial nitric oxide synthase, along with significantly higher perfusate levels of the endogenous vasodilator nitric oxide. Functional efficiency of PP over CS was confirmed in additional porcine transplant experiments (n=5 for both) by, for example, up to threefold improved clearance of creatinine during the first days after transplantation. Conclusion. PP of 90 min shortly before transplantation seems to be an efficient mechanism to reduce proinflammatory endothelial phenotype and improve functional outcome of kidney grafts even after preceding static storage.
引用
收藏
页码:538 / 542
页数:5
相关论文
共 29 条
[1]   Experimental kidney transplantation in pigs from non-heart-beating donors:: Evaluation of renal artery flow [J].
Alcoberro, J ;
Alcaraz, A ;
Alvarez-Vijande, R ;
Calatrava, P ;
Luque, P ;
Rodriguez, A ;
Aguilar, A ;
Gibanel, R ;
Llopis, J ;
Solé, M ;
Farré, X ;
Helena, M ;
Talbot-Wright, R .
TRANSPLANTATION PROCEEDINGS, 1999, 31 (06) :2348-2349
[2]   Endothelial dysfunction in ischemic acute renal failure: rescue by transplanted endothelial cells [J].
Brodsky, SV ;
Yamamoto, T ;
Tada, T ;
Kim, B ;
Chen, J ;
Kajiya, F ;
Goligorsky, MS .
AMERICAN JOURNAL OF PHYSIOLOGY-RENAL PHYSIOLOGY, 2002, 282 (06) :F1140-F1149
[3]   Prolonged fluid shear stress induces a distinct set of endothelial cell genes, most specifically lung Kruppel-like factor (KLF2) [J].
Dekker, RJ ;
van Soest, S ;
Fontijn, RD ;
Salamanca, S ;
de Groot, PG ;
VanBavel, E ;
Pannekoek, H ;
Horrevoets, AJG .
BLOOD, 2002, 100 (05) :1689-1698
[4]   Machine perfusion versus static cold storage in expanded criteria donor kidney transplantation: 3-year follow-up data [J].
Gallinat, Anja ;
Moers, Cyril ;
Smits, Jacqueline M. ;
Strelniece, Agita ;
Pirenne, Jacques ;
Ploeg, Rutger J. ;
Paul, Andreas ;
Treckmann, Juergen .
TRANSPLANT INTERNATIONAL, 2013, 26 (06) :E52-E53
[5]   Machine perfusion versus cold storage for the preservation of kidneys from donors ≥65 years allocated in the Eurotransplant Senior Programme [J].
Gallinat, Anja ;
Moers, Cyril ;
Treckmann, Juergen ;
Smits, Jacqueline M. ;
Leuvenink, Henry G. D. ;
Lefering, Rolf ;
van Heurn, Ernest ;
Kirste, Guenter R. ;
Squifflet, Jean-Paul ;
Rahmel, Axel ;
Pirenne, Jacques ;
Ploeg, Rutger J. ;
Paul, Andreas .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2012, 27 (12) :4458-4463
[6]   Hypothermic Reconditioning of Porcine Kidney Grafts by Short-Term Preimplantation Machine Perfusion [J].
Gallinat, Anja ;
Paul, Andreas ;
Efferz, Patrik ;
Lueer, Bastian ;
Kaiser, Gernot ;
Wohlschlaeger, Jeremias ;
Treckmann, Juergen ;
Minor, Thomas .
TRANSPLANTATION, 2012, 93 (08) :787-793
[7]   Flow Cessation Triggers Endothelial Dysfunction During Organ Cold Storage Conditions: Strategies for Pharmacologic Intervention [J].
Gracia-Sancho, Jorge ;
Villarreal, Guadalupe, Jr. ;
Zhang, Yuzhi ;
Yu, Jessica X. ;
Liu, Yao ;
Tullius, Stefan G. ;
Garcia-Cardena, Guillermo .
TRANSPLANTATION, 2010, 90 (02) :142-149
[8]   Ablating the ischemia-reperfusion injury in non-heart-beating donor kidneys [J].
Hernandez, A ;
Light, JA ;
Barhyte, DY ;
Mabudian, M ;
Gage, F .
TRANSPLANTATION, 1999, 67 (02) :200-206
[9]   The Additional Detrimental Effects of Cold Preservation on Transplantation-Associated Injury in Kidneys from Living and Brain-Dead Donor Rats [J].
Hoeger, Simone ;
Petrov, Kiril ;
Reisenbuechler, Anke ;
Fontana, Johann ;
Selhorst, Jochen ;
Hanusch, Christine ;
Beck, Grietje ;
Seelen, Marc A. ;
van Son, Willem J. ;
Waldherr, Ruediger ;
Schnuelle, Peter ;
Yard, Benito A. .
TRANSPLANTATION, 2009, 87 (01) :52-58
[10]   Hypothermic reconditioning after cold storage improves postischemic graft function in isolated porcine kidneys [J].
Koetting, Martina ;
Frotscher, Carolin ;
Minor, Thomas .
TRANSPLANT INTERNATIONAL, 2010, 23 (05) :538-542