An Innovative Ultrasonic Apparatus and Technology for Diagnosis of Freeze-Drying Process

被引:5
作者
Cheng, Chin-Chi [1 ]
Tseng, Yen-Hsiang [2 ]
Huang, Shih-Chang [1 ]
机构
[1] Natl Taipei Univ Technol, Dept Energy & Refrigerating Air Conditioning Engn, Taipei 10608, Taiwan
[2] Tai Yiaeh Enterprise Co Ltd, New Taipei 23942, Taiwan
关键词
freeze-drying process diagnosis; ultrasonic transducer (UT); freezing; drying point; drying period; TEMPERATURE; QUALITY; STABILITY; MOISTURE;
D O I
10.3390/s19092181
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The freeze-drying process removes water from a product through freezing, sublimation and desorption procedures. However, the extreme conditions of the freeze-drying environment, such as the limited space, vacuum and freezing temperatures of as much as -50 degrees C, may block the ability to use certain diagnostic sensors. In this paper, an ultrasonic transducer (UT) is integrated onto the bottom of a specially designed frozen bottle for the purpose of observing the freeze-drying process of water at varying amounts. The temperatures and visual observations made with a camera are then compared with the corresponding ultrasonic signatures. Among all of the diagnostic tools and technologies available, only ultrasonic and visual records are able to analyze the entire progression of the freeze-drying process of water. Compared with typical experiment settings, the indication of drying point for water by the amplitude variations of ultrasonic L-3 echo could reduce the process period and energy consumption. This study demonstrates how an innovative frozen bottle, an integrated ultrasonic sensor and diagnostic methods used to measure and optimize the freeze-drying process of water can save energy.
引用
收藏
页数:14
相关论文
共 34 条
[1]  
Ahrens D. C., 2000, Revista Brasileira de Sementes, V22, P12
[2]  
Arnold F.J., 2014, ECTI T ELECT ENG ELE, V12, P48
[3]   SPEED OF SOUND IN PURE WATER AS A FUNCTION OF TEMPERATURE [J].
BILANIUK, N ;
WONG, GSK .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1993, 93 (03) :1609-1612
[4]   Effect of moisture on the stability of a lyophilized humanized monoclonal antibody formulation [J].
Breen, ED ;
Curley, JG ;
Overcashier, DE ;
Hsu, CC ;
Shire, SJ .
PHARMACEUTICAL RESEARCH, 2001, 18 (09) :1345-1353
[5]  
Chang BS., 2004, Lyophilization of Biopharmaceuticals, P113
[6]   Novel Real-Time Temperature Diagnosis of Conventional Hot-Embossing Process Using an Ultrasonic Transducer [J].
Cheng, Chin-Chi ;
Yang, Sen-Yeu ;
Lee, Dasheng .
SENSORS, 2014, 14 (10) :19493-19506
[7]   Substrate Effect on Characteristics of PbZrxTi1-xO3 (PZT) Film [J].
Cheng, Chin-Chi ;
Young, San-Lin ;
Chen, Hone-Zern ;
Yang, Sen-Yeu .
INTEGRATED FERROELECTRICS, 2014, 150 (01) :51-58
[8]   Real-Time Diagnosis of Gas-Assisted Hot Embossing Process by Ultrasound [J].
Cheng, Chin-Chi ;
Wu, Chia-Lin ;
Wu, Kuo-Ting ;
Yang, Sen-Yeu .
POLYMER ENGINEERING AND SCIENCE, 2013, 53 (10) :2175-2182
[9]   MICROMOLDING OF POLYMER NANOCOMPOSITES DIAGNOSED BY ULTRASOUND [J].
Cheng, Chin-Chi .
JOURNAL OF POLYMER ENGINEERING, 2010, 30 (02) :95-108
[10]   Microwave-assisted food processing technologies for enhancing product quality and process efficiency: A review of recent developments [J].
Ekezie, Flora-Glad Chizoba ;
Sun, Da-Wen ;
Han, Zhang ;
Cheng, Jun-Hu .
TRENDS IN FOOD SCIENCE & TECHNOLOGY, 2017, 67 :58-69