共 33 条
Identification of the Iodine Concentration That Yields the Highest Intravascular Enhancement in MDCT Angiography
被引:17
作者:
Behrendt, Florian F.
[1
,2
]
Pietsch, Hubertus
[3
]
Jost, Gregor
[3
]
Palmowski, Moritz
[1
,4
]
Guenther, Rolf W.
[1
]
Mahnken, Andreas H.
[1
,5
]
机构:
[1] Rhein Westfal TH Aachen, Dept Radiol, D-52074 Aachen, Germany
[2] Rhein Westfal TH Aachen, Dept Nucl Med, D-52074 Aachen, Germany
[3] Bayer HealthCare, Contrast Media Res, Berlin, Germany
[4] Rhein Westfal TH Aachen, Dept Expt Mol Imaging, D-52074 Aachen, Germany
[5] Rhein Westfal TH Aachen, Helmholtz Inst Biomed Engn, D-52074 Aachen, Germany
关键词:
contrast administration and dosage;
contrast media;
CT angiography;
iodine concentration;
DIGITAL-SUBTRACTION-ANGIOGRAPHY;
CONTRAST-MEDIA CONCENTRATIONS;
HEPATIC CT ENHANCEMENT;
COMPUTED-TOMOGRAPHY;
INJECTION PROTOCOL;
PATIENT WEIGHT;
ISO-OSMOLAR;
CHEST CT;
MODEL;
LIVER;
D O I:
10.2214/AJR.12.8984
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
OBJECTIVE. The objective of our study was to identify the iodine concentration that yields the highest intravascular contrast enhancement in MDCT angiography by intraindividual comparison in an animal model. MATERIALS AND METHODS. Six pigs underwent repeated chest MDCT examinations under standardized conditions using the same contrast medium (iopromide) with different iodine concentrations (150, 240, 300, and 370 mg I/mL). The contrast injection protocol was adapted to ensure an identical iodine delivery rate of 1.5 g I/s and the same total iodine dose of 300 mg/kg of body weight for all studies. Dynamic CT scans were acquired at the levels of the pulmonary artery and the ascending and descending aorta. Pulmonary and aortic peak enhancement values as well as time to peak (TTP) were calculated from time-enhancement curves. RESULTS. Pulmonary and aortic peak contrast enhancement values were significantly higher with the 240 and 300 mg I/mL contrast media than the 150 and 370 mg I/mL contrast media (e. g., ascending aorta: 240 vs 150, p = 0.0070; 300 vs 150, p = 0.0096; 240 vs 370, p = 0.0262; 300 vs 370, p = 0.0079). TTP values tended to be lower for the 150 mg I/mL contrast medium than for the contrast media with higher iodine concentrations. CONCLUSION. Comparison of contrast media with iodine concentrations ranging from 150 to 370 mg I/mL showed that contrast enhancement was significantly improved with the use of 240 and 300 mg I/mL contrast media given a fixed identical iodine delivery and normalized total iodine load in a porcine model. Contrast media with a moderate iodine concentration are most suitable for obtaining the highest intravascular contrast enhancement in CT angiography.