Identification of the Iodine Concentration That Yields the Highest Intravascular Enhancement in MDCT Angiography

被引:17
作者
Behrendt, Florian F. [1 ,2 ]
Pietsch, Hubertus [3 ]
Jost, Gregor [3 ]
Palmowski, Moritz [1 ,4 ]
Guenther, Rolf W. [1 ]
Mahnken, Andreas H. [1 ,5 ]
机构
[1] Rhein Westfal TH Aachen, Dept Radiol, D-52074 Aachen, Germany
[2] Rhein Westfal TH Aachen, Dept Nucl Med, D-52074 Aachen, Germany
[3] Bayer HealthCare, Contrast Media Res, Berlin, Germany
[4] Rhein Westfal TH Aachen, Dept Expt Mol Imaging, D-52074 Aachen, Germany
[5] Rhein Westfal TH Aachen, Helmholtz Inst Biomed Engn, D-52074 Aachen, Germany
关键词
contrast administration and dosage; contrast media; CT angiography; iodine concentration; DIGITAL-SUBTRACTION-ANGIOGRAPHY; CONTRAST-MEDIA CONCENTRATIONS; HEPATIC CT ENHANCEMENT; COMPUTED-TOMOGRAPHY; INJECTION PROTOCOL; PATIENT WEIGHT; ISO-OSMOLAR; CHEST CT; MODEL; LIVER;
D O I
10.2214/AJR.12.8984
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The objective of our study was to identify the iodine concentration that yields the highest intravascular contrast enhancement in MDCT angiography by intraindividual comparison in an animal model. MATERIALS AND METHODS. Six pigs underwent repeated chest MDCT examinations under standardized conditions using the same contrast medium (iopromide) with different iodine concentrations (150, 240, 300, and 370 mg I/mL). The contrast injection protocol was adapted to ensure an identical iodine delivery rate of 1.5 g I/s and the same total iodine dose of 300 mg/kg of body weight for all studies. Dynamic CT scans were acquired at the levels of the pulmonary artery and the ascending and descending aorta. Pulmonary and aortic peak enhancement values as well as time to peak (TTP) were calculated from time-enhancement curves. RESULTS. Pulmonary and aortic peak contrast enhancement values were significantly higher with the 240 and 300 mg I/mL contrast media than the 150 and 370 mg I/mL contrast media (e. g., ascending aorta: 240 vs 150, p = 0.0070; 300 vs 150, p = 0.0096; 240 vs 370, p = 0.0262; 300 vs 370, p = 0.0079). TTP values tended to be lower for the 150 mg I/mL contrast medium than for the contrast media with higher iodine concentrations. CONCLUSION. Comparison of contrast media with iodine concentrations ranging from 150 to 370 mg I/mL showed that contrast enhancement was significantly improved with the use of 240 and 300 mg I/mL contrast media given a fixed identical iodine delivery and normalized total iodine load in a porcine model. Contrast media with a moderate iodine concentration are most suitable for obtaining the highest intravascular contrast enhancement in CT angiography.
引用
收藏
页码:1151 / 1156
页数:6
相关论文
共 33 条
  • [1] Moderate versus high concentration of contrast material for aortic and hepatic enhancement and tumor-to-liver contrast at multi-detector row CT
    Awai, K
    Inoue, M
    Yagyu, Y
    Watanabe, M
    Sano, T
    Nin, S
    Koike, R
    Nishimura, Y
    Yamashita, Y
    [J]. RADIOLOGY, 2004, 233 (03) : 682 - 688
  • [2] Effect of contrast material injection duration and rate on aortic peak time and peak enhancement at dynamic CT involving injection protocol with dose tailored to patient weight
    Awai, K
    Hiraishi, K
    Hori, S
    [J]. RADIOLOGY, 2004, 230 (01) : 142 - 150
  • [3] Aortic and hepatic contrast medium enhancement at CT part II. Effect of reduced cardiac output in a porcine model
    Bae, KT
    Heiken, JP
    Brink, JA
    [J]. RADIOLOGY, 1998, 207 (03) : 657 - 662
  • [4] Aortic and hepatic contrast medium enhancement at CT part I. Prediction with a computer model
    Bae, KT
    Heiken, JP
    Brink, JA
    [J]. RADIOLOGY, 1998, 207 (03) : 647 - 655
  • [5] Intraindividual comparison of contrast media concentrations for combined abdominal and thoracic MDCT
    Behrendt, Florian F.
    Mahnken, Andreas H.
    Stanzel, Sven
    Seidensticker, Peter
    Jost, Edgar
    Guenther, Rolf W.
    Muehlenbruch, Georg
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 191 (01) : 145 - 150
  • [6] Low-osmolar monomeric versus iso-osmolar dimeric contrast media: An intra-individual comparison in CT angiography using an animal model
    Behrendt, Florian F.
    Pietsch, Hubertus
    Jost, Gregor
    Keil, Sebastian
    Mottaghy, Felix M.
    Guenther, Rolf W.
    Mahnken, Andreas H.
    [J]. JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2011, 55 (02) : 170 - 175
  • [7] Intra-individual comparison of different contrast media concentrations (300 mg, 370 mg and 400 mg iodine) in MDCT
    Behrendt, Florian F.
    Pietsch, Hubertus
    Jost, Gregor
    Sieber, Martin A.
    Keil, Sebastian
    Plumhans, Cedric
    Seidensticker, Peter
    Guenther, Rolf W.
    Mahnken, Andreas H.
    [J]. EUROPEAN RADIOLOGY, 2010, 20 (07) : 1644 - 1650
  • [8] Effect of different saline chaser volumes and flow rates on intravascular contrast enhancement in CT using a circulation phantom
    Behrendt, Florian F.
    Bruners, Philipp
    Keil, Sebastian
    Plumhans, Cedric
    Mahnken, Andreas H.
    Das, Marco
    Ackermann, Diana
    Guenther, Rolf W.
    Muehlenbruch, Georg
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2010, 73 (03) : 688 - 693
  • [9] Contrast Enhancement in Chest Multidetector Computed Tomography: Intraindividual Comparison of 300 mg/ml versus 400 mg/ml Iodinated Contrast Medium
    Behrendt, Florian F.
    Plumhans, Cedric
    Keil, Sebastian
    Muehlenbruch, Georg
    Das, Marco
    Seidensticker, Peter
    Mutscher, Christina
    Guenther, Rolf W.
    Mahnken, Andreas H.
    [J]. ACADEMIC RADIOLOGY, 2009, 16 (02) : 144 - 149
  • [10] High iodine concentration contrast material for noninvasive multislice computed tomography coronary angiography - Iopromide 370 versus iomeprol 400
    Cademartiri, F
    de Monye, C
    Pugliese, F
    Mollet, NR
    Runza, G
    van der Lugt, A
    Midiri, M
    de Feyter, PJ
    Lagalla, R
    Krestin, GP
    [J]. INVESTIGATIVE RADIOLOGY, 2006, 41 (03) : 349 - 353