Pinhole aperture design for I-131 tumor imaging

被引:32
作者
Smith, MF [1 ]
Jaszczak, RJ [1 ]
Wang, HL [1 ]
机构
[1] DUKE UNIV, MED CTR, DEPT RADIOL, DURHAM, NC 27710 USA
关键词
D O I
10.1109/23.596980
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A new pinhole aperture design for single photon imaging is introduced whose distinctive feature is a cylindrical channeled aperture. This allows greater attenuation near the pinhole aperture, which is especially important when imaging I-131 with its medium and high energy emissions. The new design reduces to a conventional knife-edge aperture when the channel height is zero. Point source response functions were simulated for pinhole inserts with different pinhole diameters (0.4 - 2.0 mm diameter) and channel heights (0.1 - 3.0 mm) with acquisition parameters appropriate for I-131 brain tumor imaging. A photon transport simulation code was used to comprehensively model photon transport and detection. Tradeoff curves between resolution and sensitivity suggest that varying pinhole diameter and channel height to achieve higher resolution at the expense of decreased sensitivity may be advantageous for imaging tumors with intratumoral administration of I-131 radiolabeled monoclonal antibodies.
引用
收藏
页码:1154 / 1160
页数:7
相关论文
共 18 条
[1]  
Anger H. O., 1959, MED RADIOISOTOPE SCA, P59
[2]  
Barrett HH., 1981, RADIOLOGICAL IMAGING
[3]  
BICE A N, 1991, Journal of Nuclear Medicine, V32, P1058
[4]   PHASE-I STUDIES OF TREATMENT OF MALIGNANT GLIOMAS AND NEOPLASTIC MENINGITIS WITH I-131 RADIOLABELED MONOCLONAL-ANTIBODIES ANTI-TENASCIN 81C6 AND ANTI-CHONDROITIN PROTEOGLYCAN SULFATE ME1-14 F(AB')(2) - A PRELIMINARY-REPORT [J].
BIGNER, DD ;
BROWN, M ;
COLEMAN, RE ;
FRIEDMAN, AH ;
FRIEDMAN, HS ;
MCLENDON, RE ;
BIGNER, SH ;
ZHAO, XG ;
WIKSTRAND, CJ ;
PEGRAM, CN ;
KERBY, T ;
ZALUTSKY, MR .
JOURNAL OF NEURO-ONCOLOGY, 1995, 24 (01) :109-122
[5]  
Brown MT, 1996, CLIN CANCER RES, V2, P963
[6]   Evaluation of a pinhole collimator for I-131 SPECT head imaging [J].
Gilland, DR ;
Johnson, EL ;
Turkington, TG ;
Coleman, RE ;
Jaszczak, RJ .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (04) :2230-2238
[7]  
Gunter D., 1996, NUCL MED-NUKL, P96
[8]  
ISHIZU K, 1995, J NUCL MED, V36, P2282
[9]   PINHOLE COLLIMATION FOR ULTRA-HIGH-RESOLUTION, SMALL-FIELD-OF-VIEW SPECT [J].
JASZCZAK, RJ ;
LI, JY ;
WANG, HL ;
ZALUTSKY, MR ;
COLEMAN, RE .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (03) :425-437
[10]   PINHOLE SPECT FOR IMAGING IN-111 IN THE HEAD [J].
JOHNSON, EL ;
JASZCZAK, RJ ;
WANG, H ;
LI, J ;
GREER, KL ;
COLEMAN, RE .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) :1126-1132