Comparison of the retinal image quality with a Hartmann-Shack wavefront sensor and a double-pass instrument

被引:185
作者
Díaz-Doutón, F
Benito, A
Pujol, J
Arjona, M
Güell, JL
Artal, P
机构
[1] Univ Murcia, Dept Fis, Lab Opt, E-30071 Murcia, Spain
[2] Univ Politecn Cataluna, Ctr Desenvolupament Sensor Instrumentacio & Siste, Terrassa, Spain
[3] Univ Autonoma Barcelona, E-08193 Barcelona, Spain
[4] IMO, Barcelona, Spain
关键词
D O I
10.1167/iovs.05-1049
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. Wavefront sensors provide quite Useful information on the optical quality of the eye. However, in eyes where very high-order aberrations and scattered light are prominent, wave-front sensors may overestimate retinal image quality. This study showed that, in those cases, the double-pass technique is complementary tool for better estimation of ocular optical quality. METHODS. A double-pass (DP) instrument was used, based on recording images of a point source in near-infrared light after reflection in the retina and double-pass through the Ocular media. The aberrations were also measured with a prototype of near-infrared Hartmann-Shack (HS) wavefront sensor adapted to the clinical environment. From the wave aberrations, the modulation transfer function (MTF) was calculated (MTF_HS). The mTF was also obtained from the double-pass images (MTF_DP). Both techniques were applied in normal young subjects as the control and in three other groups of eyes: older subjects, after LASIK refractive surgery, and after IOL implantation. RESULTS. The MTFs obtained from DP and HS techniques were compared. In the group of normal eyes with low levels of intraocular scattering, these estimates were quite similar, indicating that both techniques captured well most of the optical degradation. However, in eves where scatter was more predominant (e.g., early cataract, posterior capsular opacification after IOL implantation) the MTF provided by the HS sensor was always higher than the MTF obtained from DP. A single parameter was used to indicate the differences. CONCLUSIONS. In eyes with low scattering, DP and HS techniques provided similar estimates of the retinal image quality. However, in a patient's eye with mild to severe amount Of scatter, wavefront sensors might overestimate image quality, whereas the DP technique produces a more accurate description of the optical quality, better correlated with the quality of vision.
引用
收藏
页码:1710 / 1716
页数:7
相关论文
共 39 条
  • [1] ALLEN MJ, 1967, AMER J OPT ARCH AM A, V44, P717
  • [2] Ocular static and dynamic light scattering: a noninvasive diagnostic tool for eye research and clinical practice
    Ansari, RR
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2004, 9 (01) : 22 - 37
  • [3] A CINEMATOGRAPHIC METHOD FOR THE DYNAMIC STUDY OF THE IMAGE-FORMATION BY THE HUMAN-EYE - MICROFLUCTUATIONS OF THE ACCOMMODATION
    ARNULF, A
    SANTAMARIA, J
    BESCOS, J
    [J]. JOURNAL OF OPTICS-NOUVELLE REVUE D OPTIQUE, 1981, 12 (02): : 123 - 128
  • [4] ODD ABERRATIONS AND DOUBLE-PASS MEASUREMENTS OF RETINAL IMAGE QUALITY
    ARTAL, P
    MARCOS, S
    NAVARRO, R
    WILLIAMS, DR
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1995, 12 (02): : 195 - 201
  • [5] Neural compensation for the eye's optical aberrations
    Artal, P
    Chen, L
    Fernández, EJ
    Singer, B
    Manzanera, S
    Williams, DR
    [J]. JOURNAL OF VISION, 2004, 4 (04): : 281 - 287
  • [6] Contribution of the cornea and internal surfaces to the change of ocular aberrations with age
    Artal, P
    Berrio, E
    Guirao, A
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2002, 19 (01): : 137 - 143
  • [7] SIMULTANEOUS MEASUREMENT OF 2-POINT-SPREAD FUNCTIONS AT DIFFERENT LOCATIONS ACROSS THE HUMAN FOVEA
    ARTAL, P
    NAVARRO, R
    [J]. APPLIED OPTICS, 1992, 31 (19): : 3646 - 3656
  • [8] EFFECTS OF AGING IN RETINAL IMAGE QUALITY
    ARTAL, P
    FERRO, M
    MIRANDA, I
    NAVARRO, R
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1993, 10 (07): : 1656 - 1662
  • [9] THROUGH FOCUS IMAGE QUALITY OF EYES IMPLANTED WITH MONOFOCAL AND MULTIFOCAL INTRAOCULAR LENSES
    ARTAL, P
    MARCOS, S
    NAVARRO, R
    MIRANDA, I
    FERRO, M
    [J]. OPTICAL ENGINEERING, 1995, 34 (03) : 772 - 779
  • [10] DOUBLE-PASS MEASUREMENTS OF THE RETINAL-IMAGE QUALITY WITH UNEQUAL ENTRANCE AND EXIT PUPIL SIZES AND THE REVERSIBILITY OF THE EYES OPTICAL-SYSTEM
    ARTAL, P
    IGLESIAS, I
    LOPEZGIL, N
    GREEN, DG
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1995, 12 (10): : 2358 - 2366