Phase Shift Analysis and Phase Identification for Distribution System with 3-Phase Unbalanced Constant Current Loads

被引:4
|
作者
Byun, Hee-Jung [1 ]
Shon, Sugoog [1 ]
机构
[1] Univ Suwon, Dept Informat & Telecommun Engn, Suwon, South Korea
关键词
Simulink; Phase identification; Unbalanced load; Simulation; Distribution lines;
D O I
10.5370/JEET.2013.8.4.729
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Power grids are large complicated networks in use around. An absolute phase value for a particular unknown-phase line at a local site should be identified for the operation and management of a 3-phase distribution network. The phase shift for a specific point in the line, as compared with a phase reference point at a substation, must be within a range of +/- 60 degrees for correct identification. However, the phase shift at a particular point can fluctuate depending on the line constants, transformer wiring method, line length, and line amperage, etc. Conducted in this study is a theoretical formulation for the determination of phase at a specific point in the line, Simulink modeling, and analysis for a distribution network. In particular, through evaluating the effects of unbalanced current loads, the limitations of the present phase identification methods are described.
引用
收藏
页码:729 / 736
页数:8
相关论文
共 50 条
  • [1] Injecting current control method for 3-phase unbalanced voltage suppression in distribution system
    He, Leisisi
    Zhou, Feng
    Wang, Wen
    Zeng, Xiangjun
    2015 5TH INTERNATIONAL CONFERENCE ON ELECTRIC UTILITY DEREGULATION AND RESTRUCTURING AND POWER TECHNOLOGIES (DRPT 2015), 2015, : 1214 - 1219
  • [2] MEASUREMENT OF THE POWER-FACTOR OF 3-PHASE UNBALANCED LOADS
    KHOMYAK, VA
    RAINING, D
    ELECTRICAL TECHNOLOGY, 1994, (04): : 69 - 74
  • [3] Compenstion of Phase Voltage Error in Unbalanced 3-Phase at Integrated ESS and UPS System
    Kim, Min-gi
    Choi, Bong-yeun
    Kim, Jun-gu
    Won, Chung-yuen
    Jung, Yong-chae
    2014 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY (ICIT), 2014, : 578 - 582
  • [4] UNBALANCED VOLTAGE CONTROL OF 3-PHASE LOADS BY TRIGGERING OF SILICON CONTROLLED RECTIFIERS
    SHEPHERD, W
    STANWAY, J
    IEEE TRANSACTIONS ON INDUSTRY AND GENERAL APPLICATIONS, 1965, IGA1 (03): : 206 - &
  • [5] An example of 3-phase transformer modeling for distribution system analysis
    Dugan, RC
    Santoso, S
    2003 IEEE PES TRANSMISSION AND DISTRIBUTION CONFERENCE & EXPOSITION, VOLS 1-3, CONFERENCE PROCEEDINGS: BLAZING TRAILS IN ENERGY DELIVERY AND SERVICES, 2003, : 1028 - 1032
  • [6] MEASUREMENTS OF POWER AND CURRENT COMPONENTS IN UNBALANCED AND DISTORTED 3-PHASE SYSTEMS
    ANDRIA, G
    SALVATORE, L
    SAVINO, M
    TROTTA, A
    EUROPEAN TRANSACTIONS ON ELECTRICAL POWER ENGINEERING, 1993, 3 (01): : 75 - 83
  • [7] AN ELECTRONIC PHASE BALANCER FOR 3-PHASE 3-WIRE LOADS
    SANKARAN, P
    KUMAR, VJ
    PROCEEDINGS OF THE IEEE, 1986, 74 (01) : 233 - 234
  • [8] ANALYSIS OF 3-PHASE WOUND MOTORS UNDER UNBALANCED CONDITIONS
    ABOUFADDAN, HI
    ELECTRIC POWER SYSTEMS RESEARCH, 1984, 8 (01) : 9 - 14
  • [9] 3-Phase fault current limiter for distribution systems
    Sood, Vijay K.
    Alam, Shahabur
    2006 IEEE INTERNATIONAL CONFERENCE ON POWER ELECTRONIC, DRIVES AND ENERGY SYSTEMS, VOLS 1 AND 2, 2006, : 729 - +
  • [10] 3-PHASE CURRENT MONITOR
    COOPER, JD