Perfusion phantom: An efficient and reproducible method to simulate myocardial first-pass perfusion measurements with cardiovascular magnetic resonance

被引:33
作者
Chiribiri, Amedeo [1 ,2 ,3 ]
Schuster, Andreas [1 ,2 ,3 ]
Ishida, Masaki [1 ,2 ,3 ]
Hautvast, Gilion [4 ]
Zarinabad, Niloufar [1 ,2 ,3 ]
Morton, Geraint [1 ,2 ,3 ]
Otton, James [1 ,2 ,3 ]
Plein, Sven [1 ,2 ,3 ,5 ]
Breeuwer, Marcel [4 ,6 ]
Batchelor, Philip [1 ,2 ,3 ]
Schaeffter, Tobias [1 ,2 ,3 ]
Nagel, Eike [1 ,2 ,3 ]
机构
[1] Kings Coll London, NIHR Biomed Res Ctr, Div Imaging Sci, BHF Ctr Excellence, London SE1 7EH, England
[2] Wellcome Trust Res Labs, London, England
[3] Guys & St Thomas NHS Fdn Trust, Rayne Inst, EPSRC Med Engn Ctr, London, England
[4] Philips Healthcare, Imaging Syst MR, Best, Netherlands
[5] Univ Leeds, Div Cardiovasc & Neuronal Remodelling, Leeds, W Yorkshire, England
[6] Eindhoven Univ Technol, Dept Biomed Engn, NL-5600 MB Eindhoven, Netherlands
基金
英国工程与自然科学研究理事会; 英国惠康基金;
关键词
first-pass perfusion MR; phantom; gadolinium; 3T; heart; CORONARY-ARTERY-DISEASE; MODEL-INDEPENDENT DECONVOLUTION; POSITRON-EMISSION-TOMOGRAPHY; BLOOD-FLOW; CONTRAST AGENTS; HEALTHY HUMANS; K-SPACE; RESERVE; MRI; QUANTIFICATION;
D O I
10.1002/mrm.24299
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this article is to describe a novel hardware perfusion phantom that simulates myocardial first-pass perfusion allowing comparisons between different MR techniques and validation of the results against a true gold standard. MR perfusion images were acquired at different myocardial perfusion rates and variable doses of gadolinium and cardiac output. The system proved to be sensitive to controlled variations of myocardial perfusion rate, contrast agent dose, and cardiac output. It produced distinct signal intensity curves for perfusion rates ranging from 1 to 10 mL/mL/min. Quantification of myocardial blood flow by signal deconvolution techniques provided accurate measurements of perfusion. The phantom also proved to be very reproducible between different sessions and different operators. This novel hardware perfusion phantom system allows reliable, reproducible, and efficient simulation of myocardial first-pass MR perfusion. Direct comparison between the results of image-based quantification and reference values of flow and myocardial perfusion will allow development and validation of accurate quantification methods. Magn Reson Med, 2013. (c) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:698 / 707
页数:10
相关论文
共 32 条
  • [1] Noninvasive detection of myocardial ischemia from perfusion reserve based on cardiovascular magnetic resonance
    Al-Saadi, N
    Nagel, E
    Gross, M
    Bornstedt, A
    Schnackenburg, B
    Klein, C
    Klimek, W
    Oswald, H
    Fleck, E
    [J]. CIRCULATION, 2000, 101 (12) : 1379 - 1383
  • [2] Magnetization exchange in capillaries by microcirculation affects diffusion-controlled spin-relaxation: A model which describes the effect of perfusion on relaxation enhancement by intravascular contrast agents
    Bauer, WR
    Hiller, KH
    Roder, F
    Rommel, E
    Ertl, G
    Haase, A
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (01) : 43 - 55
  • [3] Chiribiri Amedeo, 2009, Curr Cardiol Rep, V11, P54
  • [4] Absolute myocardial perfusion in canines measured by using dual-bolus first-pass MR imaging
    Christian, TF
    Rettmann, DW
    Aletras, AH
    Liao, SL
    Taylor, JL
    Balaban, RS
    Arai, AE
    [J]. RADIOLOGY, 2004, 232 (03) : 677 - 684
  • [5] Estimation of absolute myocardial blood flow during first-pass MR perfusion imaging using a dual-bolus injection technique: Comparison to single-bolus injection method
    Christian, Timothy F.
    Aletras, Anthony H.
    Arai, Andrew E.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (06) : 1271 - 1277
  • [6] Quantitative magnetic resonance perfusion imaging detects anatomic and physiologic coronary artery disease as measured by coronary angiography and fractional flow reserve
    Costa, Marco A.
    Shoemaker, Steven
    Futamatsu, Hideki
    Klassen, Chris
    Anglolillo, Dominick J.
    Nguyen, Minh
    Siuciak, Alan
    Gilmore, Paul
    Zenni, Martin M.
    Guzman, Luis
    Bass, Theodore A.
    Wilke, Norbert
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 50 (06) : 514 - 522
  • [7] Development of a dynamic flow imaging phantom for dynamic contrast-enhanced CT
    Driscoll, B.
    Keller, H.
    Coolens, C.
    [J]. MEDICAL PHYSICS, 2011, 38 (08) : 4866 - 4880
  • [8] Measurement of myocardial frequency offsets during first pass of a gadolinium-based contrast agent in perfusion studies
    Ferreira, Pedro
    Gatehouse, Peter
    Bucciarelli-Ducci, Chiara
    Wage, Ricardo
    Firmin, David
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (04) : 860 - 870
  • [9] Quantification of MRI measured myocardial perfusion reserve in healthy humans: A comparison with positron emission tomography
    Fritz-Hansen, Thomas
    Hove, Jens D.
    Kofoed, Klaus F.
    Kelbaek, Henning
    Larsson, Henrik B. W.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (04) : 818 - 824
  • [10] MR myocardial perfusion Imaging with k-space and time broad-use linear acquisition speed-up technique: Feasibility study
    Gebker, Rolf
    Jahnke, Cosima
    Paetsch, Ingo
    Schnackenburg, Bernhard
    Kozerke, Sebastian
    Bornstedt, Axel
    Fleck, Eckart
    Nagel, Eike
    [J]. RADIOLOGY, 2007, 245 (03) : 863 - 871