QRS artifact elimination on full night sleep EEG

被引:17
作者
Lanquart, JP [1 ]
Dumont, M
Linkowski, P
机构
[1] Free Univ Brussels, Erasme Acad Hosp, Dept Psychiat, Sleep Lab, B-1050 Brussels, Belgium
[2] Univ Mons, Phys Biol Lab, B-7000 Mons, Belgium
关键词
sleep EEG; artifact subtractions; morphological filters;
D O I
10.1016/j.medengphy.2005.04.017
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Spectral analysis is now a standard procedure for analyzing the electroencephalograms (EEG) obtained by polysomnographic recordings. These numerical methods assume an artifact-free EEG since artifacts create spurious spectral components. Our aim was the development of a QRS artifact removal technique that might be applied to full night EEG with a minimal human intervention. This technique should handle one EEG channel, with or without use of one ECG channel. Variance minimization, independent component analysis (ICA), morphological filters (MF) have been implemented. Careful attention has been given to define the MF structuring element. The tests on artifact-simulated and real data were checked on the residual ECG spectral components present in the cleaned EEG. The best results are obtained by the MF when the structuring element is an artifact template defined either directly on the EEG or on the ICA ECG component. Further developments are required to identify and subtract the T-wave artifacts. (c) 2005 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:156 / 165
页数:10
相关论文
共 18 条
[1]   Artifact processing in computerized analysis of sleep EEG -: A review [J].
Anderer, P ;
Roberts, S ;
Schlögl, A ;
Gruber, G ;
Klösch, G ;
Herrmann, W ;
Rappelsberger, P ;
Filz, O ;
Barbanoj, MJ ;
Dorffner, G ;
Saletu, B .
NEUROPSYCHOBIOLOGY, 1999, 40 (03) :150-157
[2]   Slow (0.7-2 Hz) and fast (2-4 Hz) delta components are differently correlated to theta, alpha and beta frequency bands during NREM sleep [J].
Benoit, O ;
Daurat, A ;
Prado, J .
CLINICAL NEUROPHYSIOLOGY, 2000, 111 (12) :2103-2106
[3]   Electrocardiogram signal preprocessing for automatic detection of QRS boundaries [J].
Daskalov, IK ;
Christov, II .
MEDICAL ENGINEERING & PHYSICS, 1999, 21 (01) :37-44
[4]   Cardiac field effects on the EEG [J].
Dirlich, G ;
Vogl, L ;
Plaschke, M ;
Strian, F .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1997, 102 (04) :307-315
[5]   REMOVAL OF EYE-MOVEMENT AND ECG ARTIFACTS FROM THE NON-CEPHALIC REFERENCE EEG [J].
FORTGENS, C ;
DEBRUIN, MP .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1983, 56 (01) :90-96
[6]   Independent component analysis:: algorithms and applications [J].
Hyvärinen, A ;
Oja, E .
NEURAL NETWORKS, 2000, 13 (4-5) :411-430
[7]   Artifact correction of the ongoing EEG using spatial filters based on artifact and brain signal topographies [J].
Ille, N ;
Berg, P ;
Scherg, M .
JOURNAL OF CLINICAL NEUROPHYSIOLOGY, 2002, 19 (02) :113-124
[8]  
Jung TP, 2000, PSYCHOPHYSIOLOGY, V37, P163, DOI 10.1017/S0048577200980259
[9]   A study of the dynamic interactions between sleep EEG and heart rate variability in healthy young men [J].
Jurysta, F ;
van de Borne, P ;
Migeotte, PF ;
Dumont, M ;
Lanquart, JP ;
Degaute, JP ;
Linkowski, P .
CLINICAL NEUROPHYSIOLOGY, 2003, 114 (11) :2146-2155
[10]   A SIMPLE FORMAT FOR EXCHANGE OF DIGITIZED POLYGRAPHIC RECORDINGS [J].
KEMP, B ;
VARRI, A ;
ROSA, AC ;
NIELSEN, KD ;
GADE, J .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1992, 82 (05) :391-393