Scheme to improve the reconstructed image in parallel quasi-phase-shifting digital holography

被引:40
作者
Awatsuji, Y [1 ]
Sasada, M
Fujii, A
Kubota, T
机构
[1] Kyoto Inst Technol, Dept Elect & Informat Sci, Sakyo Ku, Kyoto 6068585, Japan
[2] Japan Sci & Technol Agcy, PRESTO, Kawaguchi, Saitama 3320012, Japan
关键词
D O I
10.1364/AO.45.000968
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We propose a scheme to improve the reconstructed image in parallel quasi-phase-shifting digital holography. Parallel quasi-phase-shifting digital holography is a technique capable of noiseless instantaneous measurement of three-dimensional objects, and it implements four kinds of phase shifting at a time with an array of 2 x 2 phase-shifting devices located in the reference wave. In the phase-shifting calculation in the reconstruction process of the technique, the scheme assigns the 2 x 2 cell configuration for each pixel in the vertical direction and for each 1-pixel interval in the horizontal direction of the hologram recorded by the image sensor. We conduct both a numerical simulation and a preliminary experiment. The results show that the proposed scheme can improve the quality of the reconstructed image calculated by the conventional scheme of parallel quasi-phase-shifting digital holography we previously proposed, and then the effectiveness of the proposed scheme is verified. (c) 2006 Optical Society of America.
引用
收藏
页码:968 / 974
页数:7
相关论文
共 70 条
  • [1] Parallel quasi-phase-shifting digital holography
    Awatsuji, Y
    Sasada, M
    Kubota, T
    [J]. APPLIED PHYSICS LETTERS, 2004, 85 (06) : 1069 - 1071
  • [2] Application of the two-dimensional fractional-order Fourier transformation to particle field digital holography
    Coëtmellec, S
    Lebrun, D
    Özkul, C
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2002, 19 (08) : 1537 - 1546
  • [3] Holographic particle image velocimetry: signal recovery from under-sampled CCD data
    Coupland, JM
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2004, 15 (04) : 711 - 717
  • [4] Spatial filtering for zero-order and twin-image elimination in digital off-axis holography
    Cuche, E
    Marquet, P
    Depeursinge, C
    [J]. APPLIED OPTICS, 2000, 39 (23) : 4070 - 4075
  • [5] De Nicola S, 2002, OPT LASER ENG, V37, P331, DOI 10.1016/S0143-8166(01)00087-2
  • [6] Improved three-dimensional imaging with a digital holography microscope with a source of partial spatial coherence
    Dubois, F
    Joannes, L
    Legros, JC
    [J]. APPLIED OPTICS, 1999, 38 (34) : 7085 - 7094
  • [7] Digital holographic microscope with automatic focus tracking by detection sample displacement in real time
    Ferraro, P
    Coppola, G
    De Nicola, S
    Finizio, A
    Pierattini, G
    [J]. OPTICS LETTERS, 2003, 28 (14) : 1257 - 1259
  • [8] Compensation of the inherent wave front curvature in digital holographic coherent microscopy for quantitative phase-contrast imaging
    Ferraro, P
    De Nicola, S
    Finizio, A
    Coppola, G
    Grilli, S
    Magro, C
    Pierattini, G
    [J]. APPLIED OPTICS, 2003, 42 (11) : 1938 - 1946
  • [9] Digital in-line holography: influence of the reconstruction function on the axial profile of a reconstructed particle image
    Fournier, C
    Ducottet, C
    Fournel, T
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2004, 15 (04) : 686 - 693
  • [10] Comparison of passive ranging integral imaging and active imaging digital holography for three-dimensional object recognition
    Frauel, Y
    Tajahuerce, E
    Matoba, O
    Castro, A
    Javidi, B
    [J]. APPLIED OPTICS, 2004, 43 (02) : 452 - 462