Implementation of Synthesized Two-dimensional Mammography in a Population-based Digital Breast Tomosynthesis Screening Program

被引:122
作者
Zuckerman, Samantha P. [1 ]
Conant, Emily F. [1 ]
Keller, Brad M. [1 ]
Maidment, Andrew D. A. [1 ]
Barufaldi, Bruno [1 ]
Weinstein, Susan P. [1 ]
Synnestvedt, Marie [1 ]
McDonald, Elizabeth S. [1 ]
机构
[1] Hosp Univ Penn, Dept Radiol, Breast Imaging Div, 3400 Spruce St,1 Silverstein Pl, Philadelphia, PA 19104 USA
关键词
RECONSTRUCTED PROJECTION IMAGES; COMBINATION; PERFORMANCE; ACCURACY;
D O I
10.1148/radiol.2016160366
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the early implementation of synthesized two-dimensional (s2D) mammography in a population screened entirely with s2D and digital breast tomosynthesis (DBT) (referred to as s2D/DBT) and compare recall rates and cancer detection rates to historic outcomes of digital mammography combined with DBT (referred to as digital mammography/DBT) screening. Materials and Methods: This was an institutional review board-approved and HIPAA-compliant retrospective interpretation of prospectively acquired data with waiver of informed consent. Compared were recall rates, biopsy rates, cancer detection rates, and radiation dose for 15 571 women screened with digital mammography/DBT from October 1, 2011, to February 28, 2013, and 5366 women screened with s2D/DBT from January 7, 2015, to June 30, 2015. Two-sample z tests of equal proportions were used to determine statistical significance. Results: Recall rate for s2D/DBT versus digital mammography/DBT was 7.1% versus 8.8%, respectively (P,.001). Biopsy rate for s2D/DBT versus digital mammography/DBT decreased (1.3% vs 2.0%, respectively; P =.001). There was no significant difference in cancer detection rate for s2D/DBT versus digital mammography/DBT (5.03 of 1000 vs 5.45 of 1000, respectively; P =.72). The average glandular dose was 39% lower in s2D/DBT versus digital mammography/DBT (4.88 mGy vs 7.97 mGy, respectively; P,.001). Conclusion: Screening with s2D/DBT in a large urban practice resulted in similar outcomes compared with digital mammography/DBT imaging. Screening with s2D/DBT allowed for the benefits of DBT with a decrease in radiation dose compared with digital mammography/DBT. (C) RSNA, 2016
引用
收藏
页码:730 / 736
页数:7
相关论文
共 20 条
[1]  
[Anonymous], 2013, ACR BIRADS ATLAS BR
[2]  
Barufaldi B, 2015, RAD SOC N AM SCI ASS, P223
[3]   Integration of 3D digital mammography with tomosynthesis for population breast-cancer screening (STORM): a prospective comparison study [J].
Ciatto, Stefano ;
Houssami, Nehmat ;
Bernardi, Daniela ;
Caumo, Francesca ;
Pellegrini, Marco ;
Brunelli, Silvia ;
Tuttobene, Paola ;
Bricolo, Paola ;
Fanto, Carmine ;
Valentini, Marvi ;
Montemezzi, Stefania ;
Macaskill, Petra .
LANCET ONCOLOGY, 2013, 14 (07) :583-589
[4]   Breast cancer screening using tomosynthesis in combination with digital mammography compared to digital mammography alone: a cohort study within the PROSPR consortium [J].
Conant, Emily F. ;
Beaber, Elisabeth F. ;
Sprague, Brian L. ;
Herschorn, Sally D. ;
Weaver, Donald L. ;
Onega, Tracy ;
Tosteson, Anna N. A. ;
McCarthy, Anne Marie ;
Poplack, Steven P. ;
Haas, Jennifer S. ;
Armstrong, Katrina ;
Schnall, Mitchell D. ;
Barlow, William E. .
BREAST CANCER RESEARCH AND TREATMENT, 2016, 156 (01) :109-116
[5]   Breast Cancer Screening Using Tomosynthesis in Combination With Digital Mammography [J].
Friedewald, Sarah M. ;
Rafferty, Elizabeth A. ;
Rose, Stephen L. ;
Durand, Melissa A. ;
Plecha, Donna M. ;
Greenberg, Julianne S. ;
Hayes, Mary K. ;
Copit, Debra S. ;
Carlson, Kara L. ;
Cink, Thomas M. ;
Barke, Lora D. ;
Greer, Linda N. ;
Miller, Dave P. ;
Conant, Emily F. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2014, 311 (24) :2499-2507
[6]   Accuracy of Digital Breast Tomosynthesis for Depicting Breast Cancer Subgroups in a UK Retrospective Reading Study (TOMMY Trial) [J].
Gilbert, Fiona J. ;
Tucker, Lorraine ;
Gillan, Maureen G. C. ;
Willsher, Paula ;
Cooke, Julie ;
Duncan, Karen A. ;
Michell, Michael J. ;
Dobson, Hilary M. ;
Lim, Yit Yoong ;
Suaris, Tamara ;
Astley, Susan M. ;
Morrish, Oliver ;
Young, Kenneth C. ;
Duffy, Stephen W. .
RADIOLOGY, 2015, 277 (03) :697-706
[7]   The TOMMY trial: a comparison of TOMosynthesis with digital MammographY in the UK NHS Breast Screening Programme a multicentre retrospective reading study comparing the diagnostic performance of digital breast tomosynthesis and digital mammography with digital mammography alone [J].
Gilbert, Fiona J. ;
Tucker, Lorraine ;
Gillan, Maureen G. C. ;
Willsher, Paula ;
Cooke, Julie ;
Duncan, Karen A. ;
Michell, Michael J. ;
Dobson, Hilary M. ;
Lim, Yit Yoong ;
Purushothaman, Hema ;
Strudley, Celia ;
Astley, Susan M. ;
Morrish, Oliver ;
Young, Kenneth C. ;
Duffy, Stephen W. .
HEALTH TECHNOLOGY ASSESSMENT, 2015, 19 (04) :1-+
[8]   Dose Reduction in Digital Breast Tomosynthesis (DBT) Screening using Synthetically Reconstructed Projection Images: An Observer Performance Study [J].
Gur, David ;
Zuley, Margarita L. ;
Anello, Maria I. ;
Rathfon, Grace Y. ;
Chough, Denise M. ;
Ganott, Marie A. ;
Hakim, Christiane M. ;
Wallace, Luisa ;
Lu, Amy ;
Bandos, Andriy I. .
ACADEMIC RADIOLOGY, 2012, 19 (02) :166-171
[9]   Digital Breast Tomosynthesis A Brave New World of Mammography Screening [J].
Houssami, Nehmat ;
Miglioretti, Diana L. .
JAMA ONCOLOGY, 2016, 2 (06) :725-727
[10]   Screening Outcomes Following Implementation of Digital Breast Tomosynthesis in a General-Population Screening Program [J].
McCarthy, Anne Marie ;
Kontos, Despina ;
Synnestvedt, Marie ;
Tan, Kay See ;
Heitjan, Daniel F. ;
Schnall, Mitchell ;
Conant, Emily F. .
JNCI-JOURNAL OF THE NATIONAL CANCER INSTITUTE, 2014, 106 (11)