Fast contingency screening for on-line transient stability monitoring of the KEPCO system

被引:0
|
作者
Lee, J [1 ]
Lee, B [1 ]
Kwon, SH [1 ]
Nam, HK [1 ]
Choo, JB [1 ]
Yi, K [1 ]
机构
[1] Korea Univ, Sch Elect Engn, Seoul 136701, South Korea
关键词
contingency screening; transient stability monitoring; Single Machine Equivalent (SIME); direct method; KEPCO system;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this paper, a fast contingency screening algorithm using SIME for the transient stability monitoring of the KEPCO system is implemented. This method evaluates the first-swing stability of a large number of contingencies in a short time with reliable accuracy. The salient feature of the proposed screening algorithm is as follows. First, critical cluster of generators is identified by a new index in the early stage of the time domain simulation. Thus, the computational time required for finding the equivalent one machine infinite bus system can be reduced significantly. Second, clustering critical machines can perform even in very stable cases. It allows us to avoid extra calculation of the time trajectory that is needed in the SIME for classifying the stable cases. Third, the screening capability is improved using the power-angle trajectory and subdividing the contingency classification.
引用
收藏
页码:314 / 319
页数:2
相关论文
共 50 条
  • [31] Fast on-line flow injection analysis system for IgG monitoring in bioprocesses
    Reinecke, M
    Scheper, T
    JOURNAL OF BIOTECHNOLOGY, 1997, 59 (1-2) : 145 - 153
  • [32] On-Line Voltage Stability Preventive Control Considering Double Contingency
    Gu, Wei
    Wang, Rui
    Liu, Wei
    Wu, Zhi
    INTERNATIONAL REVIEW OF ELECTRICAL ENGINEERING-IREE, 2011, 6 (02): : 930 - 937
  • [33] Transient Stability Contingency Screening and Ranking based on data mining
    Dimitrovska, Teodora
    Rudez, Urban
    Mihalic, Rafael
    Kerin, Uros
    2016 IEEE PES INNOVATIVE SMART GRID TECHNOLOGIES CONFERENCE EUROPE (ISGT-EUROPE), 2016,
  • [34] On-line transient stability constrained ATC calculations
    Rosales, RA
    Ruiz-Vega, D
    Ernst, D
    Pavella, M
    Giri, J
    2000 IEEE POWER ENGINEERING SOCIETY SUMMER MEETING, CONFERENCE PROCEEDINGS, VOLS 1-4, 2000, : 1291 - 1296
  • [35] On-line estimation of wind farm transient stability
    Chiodo, E.
    Lauria, D.
    2009 INTERNATIONAL CONFERENCE ON CLEAN ELECTRICAL POWER (ICCEP 2009), VOLS 1 AND 2, 2009, : 728 - 732
  • [36] Probabilistic transient stability assessment for on-line applications
    Abapour, Mehdi
    Haghifam, Mahmoud-Reza
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2012, 42 (01) : 627 - 634
  • [37] Techniques for on-line transient stability assessment and control
    Kundur, P
    Morison, GK
    Wang, L
    2000 IEEE POWER ENGINEERING SOCIETY WINTER MEETING - VOLS 1-4, CONFERENCE PROCEEDINGS, 2000, : 46 - 51
  • [38] A novel approach for on-line transient stability assessment
    Gu, Y
    Zhang, YW
    Zhang, BM
    Hashimoto, H
    Taoka, H
    2000 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY, VOLS I-III, PROCEEDINGS, 2000, : 281 - 285
  • [39] A parallel transient stability limit search method for on-line transient stability assessment
    Jin, MJ
    Chan, KW
    Mei, SW
    Mo, N
    Lu, Q
    2004 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY - POWERCON, VOLS 1 AND 2, 2004, : 1474 - 1478
  • [40] On-line Monitoring System with LoRaWAN
    Penkov, St.
    Taneva, A.
    Petrov, M.
    IFAC PAPERSONLINE, 2019, 52 (25): : 533 - 538