Effect of suture material on gap formation and failure in type 1 FDP avulsion repairs in a cadaver model

被引:12
作者
Schreuder, F. B.
Scougall, P. J.
Puchert, E.
Vizesi, F.
Walsh, W. R.
机构
[1] Univ New S Wales, Orthopaed Res Labs, Prince Wales Hosp, Randwick, NSW 2031, Australia
[2] St Lukes Hosp, Sydney Hand Unit, Potts Point, NSW, Australia
关键词
flexor digitorum profundus tendon; suture; tendon; biomechanical testing;
D O I
10.1016/j.clinbiomech.2005.12.012
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background. An in vitro cyclical testing simulating a passive mobilisation protocol was used to compare repair of flexor digitorum profundus tendon with modified-Bunnell two-strand pullout technique using a monofilament (Prolene), braided polyester (Ethibond) and a synthetic polyfilament ensheathed by caprolactan (Supramid) sutures. Methods. Eighteen fresh-frozen cadaveric fingers were randomly divided into three repair groups (n = 6); modified-Bunnell technique with 3/0 Prolene, Ethibond or Supramid. After repair, specimens were cyclically loaded from 2 to 15 N at 5 N/s, for a total of 500 cycles. Gap formation at the tendon-bone interface was assessed every 100 cycles. Samples were tested to failure at the completion of 500 cycles. Findings. All sutures held in all specimens during cyclic testing. The gap formation after 500 cycles was greatest with Prolene suture (6.8 mm, SD 1.2) followed by Supramid suture (4.0 mm, SD 1.1) and Ethibond suture (1.7 mm, SD 1.7) (P < 0.05). Repairs with Supramid displayed higher failure load (52.7 N, SD 5.5) as compared to Prolene (37.6 N, SD 4.7) (P = 0.001) but not compared to Ethibond (44.9 N, SD 7.1). The failure loads between Prolene and Ethibond did not differ (P = 0.130). Interpretation. Gap formation with Ethibond was significantly lower compared to Supramid and Prolene. The four strand nature of the Supramid repair was superior to Prolene but did not differ compared to Ethibond with respect to failure load. Prolene is the least favourable suture when considering gap formation and failure load, while Ethibond is the most favourable. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:481 / 484
页数:4
相关论文
共 11 条
[1]  
Ketchum L D, 1985, Hand Clin, V1, P43
[2]   Cyclic testing of pullout sutures and micro-Mitek suture anchors in flexor digitorum profundus tendon distal fixation [J].
Latendresse, K ;
Dona, E ;
Scougall, PJ ;
Schreuder, FB ;
Puchert, E ;
Walsh, WR .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2005, 30A (03) :471-478
[3]  
Leddy J P, 1985, Hand Clin, V1, P77
[4]  
Leddy J P, 1977, J Hand Surg Am, V2, P66
[5]   TENDON REPAIRS WITH NYLON AND A MODIFIED PULLOUT TECHNIQUE [J].
MANGUS, DJ ;
BROWN, F ;
BYRNES, W ;
HABAL, A .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1971, 48 (01) :32-&
[6]   Primary flexor tendon repair in zone 1 [J].
Moiemen, NS ;
Elliot, D .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 2000, 25B (01) :78-84
[7]   FLEXOR TENDON REPAIR USING A 6 STRAND METHOD OF REPAIR AND EARLY ACTIVE MOBILIZATION [J].
SAVAGE, R ;
RISITANO, G .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1989, 14B (04) :396-399
[8]   FLEXOR TENDON FORCES - INVIVO MEASUREMENTS [J].
SCHUIND, F ;
GARCIAELIAS, M ;
COONEY, WP ;
AN, KN .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1992, 17A (02) :291-298
[9]   The effects of multiple-strand suture techniques on the tensile properties of repair of the flexor digitorum profundus tendon to bone [J].
Silva, MJ ;
Hollstien, SB ;
Fayazi, AH ;
Adler, P ;
Gelberman, RH ;
Boyer, MI .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (10) :1507-1514
[10]  
Strickland JW, 1999, FLEXOR TENDONS ACUTE