Augmented reality visualization for CT-guided interventions: System description, feasibility, and initial evaluation in an abdominal phantom

被引:42
作者
Das, Marco
Sauer, Frank
Schoepf, U. Joseph [1 ]
Khamene, Ali
Vogt, Sebastian K.
Schaller, Stefan
Kikinis, Ron
van Sonnenberg, Eric
Silverman, Stuart G.
机构
[1] Harvard Univ, Sch Med, Brigham & Womens Hosp, Dept Radiol, Boston, MA 02115 USA
[2] Harvard Univ, Sch Med, Brigham & Womens Hosp, Surg Planning Lab, Boston, MA 02115 USA
[3] Univ Witten Herdecke, Inst Diagnost & Intervent Radiol, Muelheim Radiol Inst, Mulheim, Germany
[4] Rhein Westfal TH Aachen, Dept Diagnost Radiol, D-5100 Aachen, Germany
[5] Siemens Corp Res, Princeton, NJ USA
[6] Med Univ S Carolina, Dept Radiol, Charleston, SC 29425 USA
[7] Siemens Med Solut, CT Div, Forchheim, Germany
[8] Harvard Univ, Sch Med, Dana Farber Canc Inst, Dept Radiol, Boston, MA 02115 USA
关键词
D O I
10.1148/radiol.2401040018
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to evaluate the feasibility and performance of an augmented reality (AR) visualization prototype for virtual computed tomography (CT)guided interventional procedures in a multimodality abdominal phantom. With the aid of AR guidance, three radiologists performed 30 attempts at targeting simulated liver lesions of different sizes ( range, 5 - 15 mm) with a biopsy needle. The position of the needle tip relative to the lesion was verified by using ultrasonography and CT. With AR guidance, lesions were successfully targeted with the first needle pass in all cases. On the basis of these results, AR visualization for CT-guided intervention appears feasible and allows intuitive and accurate lesion targeting in a phantom.
引用
收藏
页码:230 / 235
页数:6
相关论文
共 18 条
[1]   A head-mounted operating binocular for augmented reality visualization in medicine - Design and initial evaluation [J].
Birkfellner, W ;
Figl, M ;
Huber, K ;
Watzinger, F ;
Wanschitz, F ;
Hummel, J ;
Hanel, R ;
Greimel, W ;
Homolka, P ;
Ewers, R ;
Bergmann, H .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (08) :991-997
[2]   Image-guided robotic delivery system for precise placement of therapeutic agents [J].
Cleary, K ;
Freedman, M ;
Clifford, M ;
Lindisch, D ;
Onda, S ;
Jiang, L .
JOURNAL OF CONTROLLED RELEASE, 2001, 74 (1-3) :363-368
[3]  
Edwards P J, 1995, J Image Guid Surg, V1, P172, DOI 10.1002/(SICI)1522-712X(1995)1:3<172::AID-IGS7>3.0.CO
[4]  
2-7
[5]  
Grimson WEL, 1999, SCI AM, V280, P62
[6]   INTERVENTIONAL RADIOLOGY IN THE CHEST AND ABDOMEN [J].
MUELLER, PR ;
VANSONNENBERG, E .
NEW ENGLAND JOURNAL OF MEDICINE, 1990, 322 (19) :1364-1374
[7]   Patient and personnel exposure during CT fluoroscopy-guided interventional procedures [J].
Nawfel, RD ;
Judy, PF ;
Silverman, SG ;
Hooton, S ;
Tuncali, K ;
Adams, DF .
RADIOLOGY, 2000, 216 (01) :180-184
[8]  
Rogers LF, 2001, AM J ROENTGENOL, V177, P1
[9]   Augmented reality guidance for needle biopsies: An initial randomized, controlled trial in phantoms [J].
Rosenthal, M ;
State, A ;
Lee, J ;
Hirota, G ;
Ackerman, J ;
Keller, K ;
Pisano, ED ;
Jiroutek, M ;
Muller, K ;
Fuchs, H .
MEDICAL IMAGE ANALYSIS, 2002, 6 (03) :313-320
[10]  
Sauer F, 2002, ST HEAL T, V85, P455