Energy saving potential of a simple control strategy for heat exchanger network operation under fouling conditions

被引:21
作者
Trafczynski, Marian [1 ]
Markowski, Mariusz [1 ]
Urbaniec, Krzysztof [1 ]
机构
[1] Warsaw Univ Technol, Fac Civil Engn Mech & Petrochem, Inst Mech Engn, Dept Proc Equipment, Lukasiewicza 17, PL-09400 Plock, Poland
关键词
Heat exchanger network; Preheat train; Optimal operation; Near-optimal control; Control strategy; Energy saving; SELF-OPTIMIZING CONTROL; CLEANING SCHEDULE; OPTIMIZATION; INTEGRATION; INDUSTRIAL;
D O I
10.1016/j.rser.2019.05.046
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A real-life benchmark system comprising a Heat Exchanger Network operated as part of Crude Distillation Unit is considered. In such systems, the crude oil stream is typically split into parallel branches and the oil mass flows through the branches are kept in constant proportion, i.e., at constant split ratio, by the process control system. In this paper, linear control systems (proportional-integral-derivative controllers) are considered and the proposed control strategy is to adjust the parallel flows so that identical temperature values are maintained at the outlets from two parallel branches and consequently, the heat recovery in the network is maximized. The aim is to enhance the energy efficiency of the system and minimise greenhouse gas emissions. A mathematical model of the heat exchanger network was built and validated on the basis of real-life data recorded during operation of the crude distillation unit. Using MATLAB/Simulink, closed-loop control was simulated to enable comparative evaluation of the studied strategy of proportional-integral-derivative control and its potential to achieve energy savings in the operation of the distillation unit under fouling conditions. Compared to the strategy of constant split ratio, the proposed strategy of equal outlet temperatures from the network branches was found to increase the total heat recovery by about 1.5%. In the studied operation period, the heat-recovery increase fluctuated in the range 150-1100 kW and the average daily energy saving was estimated at 18 MWh.
引用
收藏
页码:355 / 364
页数:10
相关论文
共 43 条
  • [1] Optimisation of heat exchanger network cleaning schedules: Incorporating uncertainty in fouling and cleaning model parameters
    Al Ismaili, Riham
    Lee, Min Woo
    Wilson, D. Ian
    Vassiliadis, Vassilios S.
    [J]. COMPUTERS & CHEMICAL ENGINEERING, 2019, 121 : 409 - 421
  • [2] The Influence of Fouling Build-up in Condenser Tubes on Power Generated by a Condensing Turbine
    Alabrudzinski, Slawomir
    Markowski, Mariusz
    Trafczynski, Marian
    Urbaniec, Krzysztof
    [J]. PRES2016: 19TH INTERNATIONAL CONFERENCE ON PROCESS INTEGRATION, MODELING AND OPTIMIZATION FOR ENERGY SAVINGS AND POLLUTION REDUCTION, 2016, 52 : 1225 - 1230
  • [3] [Anonymous], ASP HYSYS V2004 2 NA
  • [4] [Anonymous], HTRI XCHANG SUIT V6
  • [5] [Anonymous], 2017, CHEM ENG T
  • [6] [Anonymous], 2010, INT J COMPUTER APPL
  • [7] [Anonymous], CHEM ENG T
  • [8] [Anonymous], STAND TUB EXCH MAN A
  • [9] Transient response of a co-current heat exchanger to an inlet temperature variation with time using an analytical and numerical solution
    Ansari, M. R.
    Mortazavi, V.
    [J]. NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, 2007, 52 (01) : 71 - 85
  • [10] Robust model predictive control for heat exchanger network
    Bakosova, Monika
    Oravec, Juraj
    [J]. APPLIED THERMAL ENGINEERING, 2014, 73 (01) : 924 - 930