Quantification of the energy use due to occupant behaviour collected in surveys: a case study of a green and non-green building
被引:10
作者:
Almeida, Laura M. M. C. E.
论文数: 0引用数: 0
h-index: 0
机构:
Western Sydney Univ, Sch Comp Engn & Math, Locked Bag 1797, Penrith, NSW 2751, AustraliaWestern Sydney Univ, Sch Comp Engn & Math, Locked Bag 1797, Penrith, NSW 2751, Australia
Almeida, Laura M. M. C. E.
[1
]
Tam, Vivian W. Y.
论文数: 0引用数: 0
h-index: 0
机构:
Western Sydney Univ, Sch Comp Engn & Math, Locked Bag 1797, Penrith, NSW 2751, AustraliaWestern Sydney Univ, Sch Comp Engn & Math, Locked Bag 1797, Penrith, NSW 2751, Australia
Tam, Vivian W. Y.
[1
]
Le, Khoa N.
论文数: 0引用数: 0
h-index: 0
机构:
Western Sydney Univ, Sch Engn, Penrith, NSW, AustraliaWestern Sydney Univ, Sch Comp Engn & Math, Locked Bag 1797, Penrith, NSW 2751, Australia
Le, Khoa N.
[2
]
机构:
[1] Western Sydney Univ, Sch Comp Engn & Math, Locked Bag 1797, Penrith, NSW 2751, Australia
[2] Western Sydney Univ, Sch Engn, Penrith, NSW, Australia
Energy use;
occupant behaviour;
surveys;
building simulation;
green building;
university building;
SAVING BEHAVIOR;
THERMAL COMFORT;
PERFORMANCE;
SIMULATION;
CONSUMPTION;
QUALITY;
USAGE;
D O I:
10.1080/19401493.2020.1825529
中图分类号:
TU [建筑科学];
学科分类号:
0813 ;
摘要:
Perceptions of occupants to energy use, collected in questionnaire surveys, were used as input variable for building simulations. These perceptions are related to occupant interactions with lighting, plug loads, heating, cooling, windows opening and shading. The simulations were performed to a green-rated (GB) and a non-rated building, in Sydney Australia, with similar characteristics. The simulation models were calibrated according to measured annual energy data to incorporate the collected behaviours. Occupants' behaviours (OB) were quantified in terms of energy use, greenhouse gas emissions and costs. Results show that occupants have 25% more impact on the overall energy use in the non-rated building than in the GB. In the GB occupants have a major impact in the heating function while in the non-rated building they impact the lighting system. The GB is less subjected to the direct impact of OB if the majority of its systems are automatically controlled.
Department of Building Physics and Building Ecology, Vienna University of Technology, Vienna, Austria
论文数: 0引用数: 0
h-index: 0
机构:
Department of Building Physics and Building Ecology, Vienna University of Technology, ViennaDepartment of Building Physics and Building Ecology, Vienna University of Technology, Vienna
Department of Building Physics and Building Ecology, Vienna University of Technology, Vienna, Austria
Department of Building Physics and Building Ecology, Vienna University of Technology, Vienna, Austria
论文数: 0引用数: 0
h-index: 0
机构:
Department of Building Physics and Building Ecology, Vienna University of Technology, ViennaDepartment of Building Physics and Building Ecology, Vienna University of Technology, Vienna
Department of Building Physics and Building Ecology, Vienna University of Technology, Vienna, Austria