Comparison of body composition methods: A literature analysis

被引:111
作者
Fogelholm, M [1 ]
Lichtenbelt, WV [1 ]
机构
[1] UNIV MAASTRICHT, DEPT HUMAN BIOL, MAASTRICHT, NETHERLANDS
关键词
anthropometry; body fat; multicomponent models;
D O I
10.1038/sj.ejcn.1600448
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Objective: To examine the comparability of different methods to assess percent Design: A meta-analysis on 54 papers, published in 1985-96, on healthy, adult Caucasians. Methods: The mean BF% from different studies were treated as single data points. In addition to UWW, the studies included one or more of the following methods: 3- or 4-component model, dual-energy X-ray absorptiometry (DXA), dual-energy photon absorptiometry, isotope dilution, bioimpedance (BIA), skinfolds or near-infrared interactance (NIR). Within each of the methods, the analyses were done separately for different mathematical functions, techniques or instruments. Main outcome measures: Bias (mean difference) and error (s.d. of difference) between BF% measured by UWW and the other methods. Results: The 4-component model gave 0.6 (95% confidence interval for the mean, CI: 0.1 to 1.2) BF% higher results than UWW. Also the 3-component model with body density and total body water (+ 1.4 BF%, 95% CI: + 0.3 to + 2.6), deuterium dilution (+ 1.5 BF%, 95% CI: + 0.7 to + 2.3), DXA by Norland (+ 7.2 BF%, 95% CI: 2.6 to 11.8) and BIA by Lukaski et al. (+ 2.0 BF%, 95% CI: 0.2 to 3.8) overestimated BF%, whereas BIA by Valhalla Scientific (- 2.6 BF%, 95% CI: - 4.5 to - 0.6) and skinfold equations by Jackson et al. (- 1.20, 95% CI: - 2.3 to - 0.1) showed a relative underestimation. The mean bias for the skinfold equation by Durnin & Womersley, against UWW, was 0.0 BF% (95% CI: - 1.3 to 1.3). The correlation between the size of measurement and the mean difference was significant for only NIR (r= - 0.77, P = 0.003). Conclusions: The difference between any method and UWW is dependent on the study. However, some methods have a systematical tendency for relative over- or underestimation of BF%.
引用
收藏
页码:495 / 503
页数:9
相关论文
共 86 条
  • [1] COMPOSITION OF WEIGHT-LOSS IN SEVERELY OBESE WOMEN - A NEW LOOK AT OLD METHODS
    ALBU, J
    SMOLOWITZ, J
    LICHTMAN, S
    HEYMSFIELD, SB
    WANG, J
    PIERSON, RN
    PISUNYER, FX
    [J]. METABOLISM-CLINICAL AND EXPERIMENTAL, 1992, 41 (10): : 1068 - 1074
  • [2] MEASUREMENT IN MEDICINE - THE ANALYSIS OF METHOD COMPARISON STUDIES
    ALTMAN, DG
    BLAND, JM
    [J]. JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES D-THE STATISTICIAN, 1983, 32 (03) : 307 - 317
  • [3] ARDLAW GM, 1996, AM J CLIN NUTR, V63, pS433
  • [4] Measurement of body fat in young and elderly women: Comparison between a four-compartment model and widely used reference methods
    BergsmaKadijk, JA
    Baumeister, B
    Deurenberg, P
    [J]. BRITISH JOURNAL OF NUTRITION, 1996, 75 (05) : 649 - 657
  • [5] BODY-FAT ESTIMATIONS BY ELECTRICAL-IMPEDANCE AND INFRARED INTERACTANCE
    BRODIE, DA
    ESTON, RG
    [J]. INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 1992, 13 (04) : 319 - 325
  • [6] EFFECT OF CHANGES OF WATER AND ELECTROLYTES ON THE VALIDITY OF CONVENTIONAL METHODS OF MEASURING FAT-FREE MASS
    BRODIE, DA
    ESTON, RG
    COXON, AY
    KREITZMAN, SN
    STOCKDALE, HR
    HOWARD, AN
    [J]. ANNALS OF NUTRITION AND METABOLISM, 1991, 35 (02) : 89 - 97
  • [7] BROOKEWAVELL K, 1995, EUR J CLIN NUTR, V49, P57
  • [8] IMPACT OF TOTAL-BODY WATER FLUCTUATIONS ON ESTIMATION OF BODY-FAT FROM BODY DENSITY
    BUNT, JC
    LOHMAN, TG
    BOILEAU, RA
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1989, 21 (01) : 96 - 100
  • [9] CLARK RR, 1993, MED SCI SPORT EXER, V25, P528
  • [10] COTE KD, 1993, MED SCI SPORT EXER, V25, P290