Accuracy of fully automated right ventricular quantification software with 3D echocardiography: direct comparison with cardiacmagnetic resonance and semi-automated quantification software

被引:43
|
作者
Otani, Kyoko [1 ]
Nabeshima, Yosuke [2 ]
Kitano, Tetsuji [2 ]
Takeuchi, Masaaki [1 ]
机构
[1] Univ Occupat & Environm Hlth Hosp, Dept Lab & Transfus Med, Yahatanishi Ku, Kitakyushu, Fukuoka 8078556, Japan
[2] Univ Occupat & Environm Hlth, Dept Internal Med 2, Sch Med, Yahatanishi Ku, Kitakyushu, Fukuoka 8078555, Japan
关键词
right ventricle; right ventricular volume and ejection fraction; 3D echocardiography; cardiac magnetic resonance; validation; 3-DIMENSIONAL ECHOCARDIOGRAPHY; EJECTION FRACTION;
D O I
10.1093/ehjci/jez236
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims The aim of this study was to determine the accuracy and reproducibility of a novel, fully automated 3D echocardiography (3DE) right ventricular (RV) quantification software compared with cardiac magnetic resonance (CMR) and semi-automated 3DE RV quantification software. Methods and results RV volumes and the RV ejection fraction (RVEF) were measured using a fully automated software (Philips), a semi-automated software (TomTec), and CMR in 100 patients who had undergone both CMR and 3DE examinations on the same day. The feasibility of the fully automated software was 91%. Although the fully automated software, without any manual editing, significantly underestimated RV end-diastolic volume (bias: -12.6 mL, P < 0.001) and stroke volume (-5.1 mL, P < 0.001) compared with CMR, there were good correlations between the two modalities (r = 0.82 and 0.78). No significant differences in RVEF between the fully automated software and CMR were observed, and there was a fair correlation (r = 0.72). The RVEF determined by the semi-automated software was significantly larger than that by CMR or the fully automated software (P < 0.001). The fully automated software had a shorter analysis time compared with the semi-automated software (15 s vs. 120 s, P < 0.001) and had a good reproducibility. Conclusion A novel, fully automated 3DE RV quantification software underestimated RV volumes but successfully approximated RVEF when compared with CMR. No inferiority of this software was observed when compared with the semi-automated software. Rapid analysis and higher reproducibility also support the routine adoption of this method in the daily clinical workflow.
引用
收藏
页码:787 / 795
页数:9
相关论文
共 50 条
  • [1] Feasibility and Accuracy of a Fully Automated Right Ventricular Quantification Software With Three-Dimensional Echocardiography: Comparison With Cardiac Magnetic Resonance
    Ahmad, Ashfaq
    Li, He
    Wan, Xiaojing
    Zhong, Yi
    Zhang, Yanting
    Liu, Juanjuan
    Gao, Ying
    Qian, Mingzhu
    Lin, Yixia
    Yi, Luyang
    Zhang, Li
    Li, Yuman
    Xie, Mingxing
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2021, 8
  • [2] Semi-automated echocardiographic quantification of right ventricular size and function
    Diego Medvedofsky
    Karima Addetia
    Jamie Hamilton
    Javier Leon Jimenez
    Roberto M. Lang
    Victor Mor-Avi
    The International Journal of Cardiovascular Imaging, 2015, 31 : 1149 - 1157
  • [3] SEMI-AUTOMATED DETECTION AND QUANTIFICATION OF AORTIC ATHEROMAS FROM 3D TRANSESOPHAGEAL ECHOCARDIOGRAPHY
    Tsang, Wendy
    Piazzese, Concetta
    Kronzon, Itzhak
    Sotaquira, Miguel
    Weinert, Lynn
    Lang, Roberto M.
    Caiani, Enrico
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (10) : E974 - E974
  • [4] Semi-automated echocardiographic quantification of right ventricular size and function
    Medvedofsky, Diego
    Addetia, Karima
    Hamilton, Jamie
    Leon Jimenez, Javier
    Lang, Roberto M.
    Mor-Avi, Victor
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2015, 31 (06): : 1149 - 1157
  • [5] Multi-modality comparison of volumetric quantification of right ventricular volumes using a novel semi-automated border detection software
    Sugeng, Lissa
    Weinert, Lynn
    Niel, Johannes
    Steringer-Mascherbauer, Regina
    Hyca, Martin
    Bartolles, Rolf
    Schummers, Georg
    Mor-Avi, Victor
    Lang, Roberto M.
    Nesser, Hans-Joachim
    CIRCULATION, 2007, 116 (16) : 422 - 423
  • [6] Novel vendor independent software for right ventricular quantification by 3D echocardiography shows good reproducibility and improved accuracy in comparison with cardiac magnetic resonance
    Spadotto, V.
    Muraru, D.
    Cecchetto, A.
    Romeo, G.
    Aruta, P.
    Maddalozzo, A.
    Miglioranza, M. H.
    Peluso, D.
    Iliceto, S.
    Badano, L. P.
    EUROPEAN HEART JOURNAL, 2015, 36 : 604 - 604
  • [7] MyelTracer: A Semi-Automated Software for Myelin g-Ratio Quantification
    Kaiser, Tobias
    Allen, Harrison Mitchell
    Kwon, Ohyoon
    Barak, Boaz
    Wang, Jing
    He, Zhigang
    Jiang, Minqing
    Feng, Guoping
    ENEURO, 2021, 8 (04)
  • [8] MAGNETIC RESONANCE IMAGE ANALYSIS USING SEMI-AUTOMATED SOFTWARE FOR QUANTIFICATION OF KNEE ARTICULAR CARTILAGE
    Muraki, S.
    Akune, T.
    Nakamura, K.
    Kawaguchi, H.
    Yoshimura, N.
    Oka, H.
    OSTEOPOROSIS INTERNATIONAL, 2010, 21 : 256 - 256
  • [9] Non-invasive quantification of right ventricular systolic function by echocardiography: a new semi-automated approach
    Sebastian Greiner
    Florian André
    Melissa Heimisch
    Alexander Heß
    Henning Steen
    Hugo A. Katus
    Derliz Mereles
    Clinical Research in Cardiology, 2013, 102 : 229 - 235
  • [10] Non-invasive quantification of right ventricular systolic function by echocardiography: a new semi-automated approach
    Greiner, Sebastian
    Andre, Florian
    Heimisch, Melissa
    Hess, Alexander
    Steen, Henning
    Katus, Hugo A.
    Mereles, Derliz
    CLINICAL RESEARCH IN CARDIOLOGY, 2013, 102 (03) : 229 - 235